RIA45

Wiring

Hauser

9

4.4  

Post-installation check

• Is the seal undamaged?

• Is the mounting frame securely fastened on the housing of the device?

• Are the threaded rods properly tightened?

• Is the device located in the center of the panel cutout?

• Is the spacer mounted (Ex option)?

5  

Wiring

L

WARNING

Danger! Electric voltage!

The entire connection of the device must take place while the device is de-energized.

The protective ground connection must be established before all other connections. If the

protective ground is disconnected, this can be a source of danger.

Before commissioning the device, make sure that the supply voltage matches the voltage

specifications on the nameplate.

Provide suitable switch or circuit breaker in building installation. This switch must be

provided close to the device (within easy reach) and marked as a circuit breaker.

An overcurrent protection element (rated current ≤ 10 A) is required for the power cable.

• Observe the terminal designation on the front of the device.

• The mixed connection of safety extra-low voltage and dangerous contact voltage to the

relay is permitted.

5.1  

Electrical connection

A loop power supply (LPS) is provided for every input. The loop power supply is primarily

designed to supply power to 2-wire sensors and is galvanically isolated from the system and

the outputs.

Содержание ria45

Страница 1: ...a substitute for the Operating Instructions pertaining to the device Detailed information is provided in the Operating Instructions and other documentation Available for all device versions via Intern...

Страница 2: ...RIA45 2 Endress Hauser Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555...

Страница 3: ...ounting procedure 8 4 4 Post installation check 9 5 Wiring 9 5 1 Electrical connection 9 5 2 Post connection check 12 6 Operation 13 6 1 Operating elements 13 6 2 Display and device status indicator L...

Страница 4: ...ground prior to establishing any other connections The ground terminals are located on the interior and exterior of the device Interior ground terminal potential equalization is connected to the supp...

Страница 5: ...process variables and displays them on its multicolored screen Processes can be monitored and controlled with the device s outputs and limit relays The device is equipped with a wide array of software...

Страница 6: ...ompliance with the safety requirements and cannot be held responsible for the consequences that may result 4 Compare the scope of delivery to the contents of the order 5 Remove all the packaging mater...

Страница 7: ...transport Direct sunlight Vibration Aggressive media 4 Mounting 4 1 Installation requirements NOTICE High temperatures reduce the life time of the display To avoid heat accumulation ensure the device...

Страница 8: ...n 114 67 1 2 1 3 4 2 4 3 5 6 6 A0010404 1 Installation in a panel 1 Screw the threaded rods item 1 into the positions provided on the mounting frame item 2 Four opposing screw positions item 3 4 are a...

Страница 9: ...ger Before commissioning the device make sure that the supply voltage matches the voltage specifications on the nameplate Provide suitable switch or circuit breaker in building installation This switc...

Страница 10: ...12 R11 R13 R22 R21 R23 L N A0010228 2 Terminal assignment of device channel 2 and relays optional Note Illustrated contact position of the relays if the power supply fails We recommend you connect a s...

Страница 11: ...x8 x7 x6 x5 A0010581 RTD resistor 3 wire RTD 3 W x2 x4 x8 x7 x6 x5 A0010582 RTD resistor 4 wire RTD 4 W x2 x4 x8 x7 x6 x5 A0010583 Thermocouple TC x8 x7 A0010409 U 1 V U 1V x8 x7 A0010410 U 1 V U 1V...

Страница 12: ...20 10 50 60 Hz L N PE A0010418 Interfaces Interface for configuring with PC software A0010417 5 2 Post connection check Device condition and specifications Notes Are cables or the device damaged Visu...

Страница 13: ...t a parameter or submenu offered in the menu Within the Configuration menu Scroll step by step through the parameters menu items characters offered Change the value of the selected parameter increase...

Страница 14: ...rom a list or specific location and click Next 4 In the next window click Browse and select the directory where the driver for the TXU10 FXA291 adapter is saved The driver is installed 5 Click Finish...

Страница 15: ...f access protection is active If access protection by means of a code should be extended to the software this function should be activated in the extended device setup For this select Menu Setup Exper...

Страница 16: ...imum value indicator In the event of an error the device switches automatically between displaying the error and displaying the channel see the Device self diagnosis and Troubleshooting sections of th...

Страница 17: ...etup Symbol for expert setup Symbol for diagnostics Accept entry If this symbol is selected the entry is applied at the position specified by the user and you quit editing mode Reject entry If this sy...

Страница 18: ......

Страница 19: ......

Страница 20: ...www addresses endress com 71573626 71573626...

Отзывы: