background image

BA00280R/09/EN/02.12
71204177

SW Version:
1.00.xx

Operating Instructions

RIA16

Field Indicator

Содержание RIA14

Страница 1: ...BA00280R 09 EN 02 12 71204177 SW Version 1 00 xx Operating Instructions RIA16 Field Indicator...

Страница 2: ...k and easy commissioning Safety instructions 4 Installation 7 Wiring 10 Display and operating elements 13 Device configuration 17 Device configuration Explanation and application of all adjustable dev...

Страница 3: ...k wiring guide 11 5 2 Electrical connection 11 5 3 Degree of protection 12 5 4 Post connection check 12 6 Operating the field indicator 13 6 1 Display and operating elements 13 6 2 Configuration via o...

Страница 4: ...The installer must ensure that the measuring system is correctly wired in accordance with the wiring diagrams Invariably local regulations governing the opening and repair of electrical devices apply...

Страница 5: ...ed correctly can result in incorrect operation or the destruction of the device Note This symbol indicates an action or procedure which if not performed correctly can have an indirect effect on operat...

Страница 6: ...us areas optional Accessories eg pipe mounting kit see chapter Accessories 2 3 Certificates and approvals CE mark declaration of conformity The field indicator is designed to meet state of the art saf...

Страница 7: ...with the information you specified in the order See also section 2 2 Scope of delivery 4 1 2 Transportation and storage Note the following points Pack the device so that is protected against impact f...

Страница 8: ...e present at the installation location to mount the device correctly can be found in Section Technical data These include the ambient temperature degree of protection climate class etc 4 3 Mounting in...

Страница 9: ...ounting the field indicator on a pipe with mounting bracket steps c d Mounting kit consisting of 1 Mounting plate 2 Clamps for pipe mounting 3 4 screws 4 4 Post installation check After installing the...

Страница 10: ...ion diagrams in the specific Ex documentation for these Operating Instructions Your local E H representative is available for assistance if required Firstly open the housing of the field indicator a00...

Страница 11: ...asuring circuit There must be potential equalisation along the circuits within and outside the hazardous area I Y I Y 3 2 OC 1a1b 2 3 1a1b I Y 1a1b loop power supply active passive Terminal 2 and 3 Op...

Страница 12: ...rommet used should not be removed from the cable entry The housing cover and the cable entry must be well tightened Install the device upright in such a way that the cable entries point downwards 5 4...

Страница 13: ...tside the hazardous area a0011261 Fig 9 Operating keys of field indicator E To configure the device open the housing cover The keys E can now be accessed During configuration the display must be conne...

Страница 14: ...keys Selecting the menus Configuring parameters and numerical values After selecting the operating function the value is entered or the setting changed by pressing the or keys Note If the keys are pre...

Страница 15: ...ser defined NO TEXT XXXXX Limit LIMIT Operating mode MODE Switching setpoint SETP off Min safety with alarm Max safety with alarm Alarm OFF MIN MAX ALARM 9999 to 99999 0 0 Hysteresis HYST Response del...

Страница 16: ...is not automatically loaded in FieldCare i e the device has to be added manually Firstly add the Communication DTM PCP Readwin TXU10 FXA291 to an empty project In the Comm DTM settings set the baud ra...

Страница 17: ...vel SERV Name Description Measured value decimal point DI DP Indicates the number of places after the decimal point for the numerical display of the measuring range Selection range 0 3 places after de...

Страница 18: ...le unit DTEXT DIM DTEXT Enter a unit that can be edited as required To configure the editable unit all 5 points on the 14 segment display have to be configured Press the E key to move on to edit the n...

Страница 19: ...99 to 99999 Measured value at which a change in the switching status occurs Value range 19999 to 99999 Default 0 7 3 3 Hysteresis LIMIT HYST Options 19999 to 99999 For entering the hysteresis for the...

Страница 20: ...ing order 7 4 4 Test TEST PARAM TEST Options OFF OUT DISP Certain device functions can be tested automatically OFF default Open collector OUT Display DISP Name Description Program name PNAME Displays...

Страница 21: ...y available to service personnel 7 5 1 Resetting the device reset PRSET perform reset Service can reset the settings to the default values Reset After selecting YES the operating parameters are set to...

Страница 22: ...e correct functioning the screws of the terminals must be tightened The device is now operational During device initialization all the segments are shown on the display for approx 1 second Caution Pri...

Страница 23: ...rder code Interface cable Commubox FXA291 incl FieldCare Device Setup DTM Library TXU10 FXA291 TXU10 AC Cable gland NPT 1 2 D4 8 5 IP68 51006845 2x cable gland M16 RK01 AA 2x adapter M16 on NTP1 2 RK0...

Страница 24: ...present if the hardware for writing and reading data EEPROM is defective or if data cannot be read properly from the EEPROM Error code Description C561 Display overflow F041 Sensor cable open circuit...

Страница 25: ...eads 4 RIA16X GC Housing bottom part plastic lasered 5 9 RIA16X EA Electronic complete Ex nonEx incl connection board cover RIA16X DA LC Display diplay board 6 51004048 Cable gland M16x1 5 PA RAL7035...

Страница 26: ...protection Input Line voltage drop 4 V at 3 22 mA Max line voltage drop 6 V at max short circuit current 200 mA 12 0 2 Output Output Digital limit switch Passive open collector Imax 200 mA Umax 35 V...

Страница 27: ...o 176 F when the Open Collector output is used Note The display can react slowly for temperatures 20 C 4 F Readability of the display cannot be guaranteed at temperatures 30 C 22 F Storage temperature...

Страница 28: ...option aluminum housing a0011162 Fig 14 Data in mm data in inches in brackets Weight Approx 500 g 1 1 lb plastic housing Approx 1 7 kg 3 75 lb aluminum housing Material Terminals Cables wires up to ma...

Страница 29: ...Limit value violation Lower upper limit value exceeded Operating elements 3 key operation E integrated in device access with housing open Remote operation Configuration The device is configured with...

Страница 30: ...vailable upon request Other standards and guidelines IEC 60529 Degree of protection by housing IP Code IEC 61010 1 Safety requirements for electrical measurement control and laboratory instrumentation...

Страница 31: ...easured value scaling 17 L LIMIT menu Hysteresis 19 Operating mode 19 Response delay 19 Switching threshold 19 LINAR 17 M MAX 19 Menu DISPL 18 INPUT 17 LIMIT 19 PARAM 19 SERV 21 MIN 19 Mounting Wall 8...

Страница 32: ...www endress com worldwide BA00280R 09 en 02 12 71204177 FM 9...