Prosonic M FMU40 HART
Mounting
Hauser
13
5.1.5
Mounting examples
A
B
C
D
A0038234
9
Mounting examples
A
With counter nut
B
With welding boss
C
With mounting bracket
D
With screw-in flange
5.1.6
Mounting the device
NOTICE
The device can be damaged.
‣
Tighten the device at the threaded boss only, with maximum 20 Nm (14.75 lbf ft).
60
A0020386
10
Mounting at threaded boss, width across flats AF60