Commissioning
Proservo NMS83
96
Hauser
9.5.2
Configuration of a connected NMT532/NMT539
If a NMT532 or NMT539 temperature transmitter is connected via HART, it can be
configured as follows:
1. Navigate to: Expert → Input/output → HART devices → HART Device(s) → NMT device
config
2. Go to the
Configure device?
parameter and select
Yes
.
3. Go to the
Bottom point
parameter and enter the position of the bottom temperature
element (see picture below).
a
A0030165
49
Position of the bottom temperature element
a
Distance from bottom temperature element to zero reference (tank bottom or datum plate). The standard
factory default setting is 500 mm (19.69 in), and it can be adjusted according to the actual installation.
To check the temperatures measured by the individual elements, go to the following
submenu: Expert → Input/output → HART devices → HD @ X NMT+WB
→ Element
values.
For additional information on settings, refer to the Operating Manual of the
Prothermo NMT532 or NMT539.
3)
In this expression, "X" is the HART address of the NMT. Its default value is "2".
Содержание Proservo NMS83
Страница 173: ...Proservo NMS83 Operating menu Endress Hauser 173 Additional information Read access Operator Write access Maintenance ...
Страница 182: ...Operating menu Proservo NMS83 182 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 218: ...Operating menu Proservo NMS83 218 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 239: ...Proservo NMS83 Operating menu Endress Hauser 239 Additional information Read access Operator Write access ...
Страница 260: ...Operating menu Proservo NMS83 260 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 275: ...Proservo NMS83 Operating menu Endress Hauser 275 Additional information Read access Operator Write access Maintenance ...
Страница 278: ...Operating menu Proservo NMS83 278 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 310: ...Operating menu Proservo NMS83 310 Endress Hauser 15 4 4 Device check submenu Navigation Diagnostics Device check ...
Страница 317: ......
Страница 318: ...www addresses endress com 71318331 71318331 ...