Proline t-mass 65 MODBUS RS485
PROCESS PARAMETER
Hauser
35
12
PROCESS PARAMETER
Function description, PROCESS PARAMETER group
PROCESS PRESSURE 1
Prerequisite
This function is
not
available if the IN-SITU CALIBRATION function has been
enabled. Refer to your Hauser service representative for more
information.
Description
Use this function to enter the process pressure for GAS GROUP 1.
(Selection and composition by means of the functions in the GAS group).
The unit is taken from the function UNIT PRESSURE (
9).
Input/display
5-digit floating-point number
Factory setting
1.0130 [bar a] or 14.692 [psi a] (country dependent
MODBUS register:
Data type:
Access:
5268
Float
read/write
PROCESS PRESSURE 2
Prerequisite
This function is
not
available if the IN-SITU CALIBRATION function has been
enabled. Refer to your Hauser service representative for more
information.
Description
Use this function to enter the process pressure for GAS GROUP 2.
(Selection and composition by means of the functions in the GAS group).
The unit is taken from the function UNIT PRESSURE (
9).
Input/display
5-digit floating-point number
Factory setting
1.0130 [bar a] or 14.692 [psi a] (country dependent
MODBUS register:
Data type:
Access:
5270
Float
read/write
PROCESS PRESSURE
Description
Use this function to display the pressure value which is used for the flow
calculation.
The value is read from the following function:
PROCESS PRESSURE 1 or 2 (depending on which gas group is active)
The unit is taken from the function UNIT PRESSURE (
Display
5-digit floating-point number
Factory setting
1.0130 [bar a] or 14.692 [psi a] (country dependent
MODBUS register:
Data type:
Access:
5185
Float
read/write
REFERENCE PRESSURE
Description
Use this function to enter the reference pressure for calculating the reference
density (for corrected volume flow measurement).
The unit is taken from the function UNIT PRESSURE (
9).
User input
:
5-digit floating-point number
Factory setting
1.0130 [bar a] or 14.692 [psi a] (country dependent
MODBUS register:
Data type:
Access:
5217
Float
read/write
REFERENCE TEMPERATURE
Description
Use this function to enter the reference temperature for calculating the
reference density (for corrected volume flow measurement).
The unit is taken from the function UNIT TEMPERATURE (
User input
5-digit floating-point number
Factory setting
0.0 [°C] or +32.0 [°F] (country dependent
MODBUS register:
Data type:
Access:
5136
Float
read/write