The innovative specialist for challenging applications with a compact, easily

accessible transmitter

Application

• Measuring principle operates independently of physical fluid

properties such as viscosity or density

• Highest measurement performance for custody transfer,

density and challenging applications

Device properties

• Mass flow: Measured error ±0.05 % (PremiumCal)

• Density: Measured error ±0.2 kg/m

3

• High turndown due to low pressure loss/zero point

• Compact dual

compartment housing with up to 3 I/Os

• Backlit display with touch control and WLAN access

• Remote display available

Your benefits

• Guaranteed measurement quality – premium accuracy for

mass flow, volume flow and density

• Optimized performance for liquids with entrained gas – MFT

(multi-frequency technology)

• Fewer process measuring points – multivariable

measurement (flow, density, temperature)

• Space

saving installation – no in/outlet run needs

• Full access to process and diagnostic information –

numerous, freely combinable I/Os and fieldbuses

• Reduced complexity and variety – freely configurable I/O

functionality

• Integrated verification – Heartbeat Technology

Products

Solutions

Services

Technical Information

Proline Promass Q 300

Coriolis flowmeter

TI01277D/06/EN/02.16

71342172

Содержание Proline Promass Q 300

Страница 1: ...ay with touch control and WLAN access Remote display available Your benefits Guaranteed measurement quality premium accuracy for mass flow volume flow and density Optimized performance for liquids wit...

Страница 2: ...on 40 Inlet and outlet runs 41 Special mounting instructions 41 Environment 43 Ambient temperature range 43 Storage temperature 43 Climate class 43 Degree of protection 43 Vibration resistance 43 Shoc...

Страница 3: ...Technology 80 Concentration 81 Accessories 81 Device specific accessories 81 Communication specific accessories 82 Service specific accessories 82 System components 83 Supplementary documentation 83 S...

Страница 4: ...ation line or a star grounding system depending on national or company codes of practice Communication symbols Symbol Meaning Wireless Local Area Network WLAN Communication via a wireless local networ...

Страница 5: ...n the mass flow Instead of a constant rotational velocity the sensor uses oscillation In the sensor two parallel measuring tubes containing flowing fluid oscillate in antiphase acting like a tuning fo...

Страница 6: ...vailable as a compact version The transmitter and sensor form a mechanical unit Transmitter Promass 300 A0026708 Device versions and materials Transmitter housing Aluminum coated aluminum AlSi10Mg coa...

Страница 7: ...w of the most important functions is provided in the following section Protecting access via hardware write protection Write access to the device parameters via the local display Web browser or operat...

Страница 8: ...ible for the management and careful handling of the access code and network key Access via fieldbus When communicating via fieldbus access to the device parameters can be restricted to Read only acces...

Страница 9: ...or gases The full scale values depend on the density of the gas and can be calculated with the formula below max G max F G x max G Maximum full scale value for gas kg h max F Maximum full scale value...

Страница 10: ...n system to the measuring device via the HART protocol The pressure transmitter must support the following protocol specific functions HART protocol Burst mode Current input The measured values are wr...

Страница 11: ...ne Promass Q 300 Endress Hauser 11 Input signal level Low signal DC 3 to 5 V High signal DC 12 to 30 V Assignable functions Off Reset the individual totalizers separately Reset all totalizers Flow ove...

Страница 12: ...MA Order code for Output input 2 021 Not assigned A A A A A A A Current output 0 4 to 20 mA B B B B Current output 0 4 to 20 mA Ex i C C C User configurable input output 1 D D D D Pulse frequency swi...

Страница 13: ...58 2 MBP galvanically isolated Data transfer 31 25 KBit s Current consumption 10 mA Permitted supply voltage 9 to 32 V Bus connection With integrated reverse polarity protection FOUNDATION Fieldbus FO...

Страница 14: ...ve Maximum output current 22 5 mA active Open circuit voltage DC 28 8 V active Pulse width Adjustable 0 05 to 2000 ms Maximum pulse rate 10000 Impulse s Pulse value Adjustable Assignable measured vari...

Страница 15: ...s one or more application packages Double pulse output Function Double pulse Version Open collector Can be set to Active Passive Maximum input values DC 30 V 250 mA passive Open circuit voltage DC 28...

Страница 16: ...for assignment Choice of current output 4 to 20 mA active 0 4 to 20 mA passive Pulse frequency switch output Choice of current input 4 to 20 mA active 0 4 to 20 mA passive Status input The technical v...

Страница 17: ...equency switch output Pulse output Failure mode Choose from Actual value No pulses Frequency output Failure mode Choose from Actual value 0 Hz Defined value f max 2 to 12500 Hz Switch output Failure m...

Страница 18: ...Safety related values Output input 1 26 27 Option BA Current output 4 to 20 mA HART Unom 30 V Umax 250 V Option GA PROFIBUS PA Unom 32 V Umax 250 V Option MA Modbus RS485 Unom 30 V Umax 250 V Option...

Страница 19: ...lass I Division 1 version 2 Only available for the Zone 2 Class I Division 2 version transmitter Order code for Output input 2 Output input 3 Output type Intrinsically safe values Intrinsically safe v...

Страница 20: ...device has one or more application packages Heartbeat Technology Application Package Additional measured variables are available with the Heartbeat Technology application package Oscillation amplitud...

Страница 21: ...olume flow Corrected volume flow Target mass flow Carrier mass flow Input values from automation system to measuring device Analog output 1 to 3 fixed assignment Analog output 1 external pressure Anal...

Страница 22: ...of the function scope of compatibility Operating Instructions 84 FOUNDATION Fieldbus Manufacturer ID 0x452B48 Ident number 0x103B Device revision 1 DD revision Information and files under www endress...

Страница 23: ...tion Transducer Block TRDEXPIN Parameters that provide information about the state of the device No output values Service Sensor Transducer Block TRDSRVS Parameters that can only be accessed by Endres...

Страница 24: ...ow flow cut off 103 Empty pipe detection 104 Status verification 105 PID Block PID 1 6 ms Multiple Analog Output Block MAO 1 5 ms Channel_0 121 Value 1 External compensation variable pressure Value 2...

Страница 25: ...ed the Promass 300 measuring device supports the compatibility of the Modbus registers for process variables and diagnostic information with the earlier Promass 83 model It is not necessary to change...

Страница 26: ...de for Input output 1 option GA PROFIBUS PA Order code for Electrical connection Cable entry 2 Cable entry 3 L N P U Plug M12 1 Order code for Input output 1 option SA FOUNDATION Fieldbus Order code f...

Страница 27: ...ting the transmitter Terminal assignment 25 Device plugs available 26 1 2 3 A0026781 1 Cable entry for supply voltage 2 Cable entry for input output signal transmission 3 Cable entry for input output...

Страница 28: ...e cable specifications 34 3 Connection for HART operating devices 70 4 Resistor for HART communication 250 observe maximum load 13 5 Analog display unit observe maximum load 13 6 Transmitter 2 3 4 20...

Страница 29: ...EMC requirements observe cable specifications 4 Analog display unit observe maximum load 5 Pressure transmitter e g Cerabar M Cerabar S see requirements 6 Transmitter PROFIBUS PA 2 1 3 4 7 8 6 6 6 6 5...

Страница 30: ...both ends to comply with EMC requirements observe cable specifications 4 T box 5 Measuring device 6 Local grounding 7 Bus terminator 8 Potential matching line Modbus RS485 2 1 A B 3 4 4 A B A B A0028...

Страница 31: ...er 2 4 20 mA 3 1 4 A0028759 9 Connection example for 4 20 mA current output passive 1 Automation system with current input e g PLC 2 Active barrier for power supply e g RN221N 3 Analog display unit ob...

Страница 32: ...0 12 Connection example for double pulse output active 1 Automation system with double pulse input e g PLC 2 Transmitter Observe input values 15 3 Double pulse output 4 Double pulse output slave phase...

Страница 33: ...put 1 Power supply 2 External measuring device for reading in pressure or temperature for instance 3 Transmitter Observe input values Status input 1 2 3 A0028764 16 Connection example for status input...

Страница 34: ...planning and commissioning BA00034S PNO Directive 2 092 PROFIBUS PA User and Installation Guideline IEC 61158 2 MBP FOUNDATION Fieldbus Twisted shielded two wire cable For further information on plann...

Страница 35: ...1 Class I Division 1 L R Maximum 24 H for Zone 1 Class I Division 1 Cable length Maximum 300 m 1000 ft see the following table Cross section Cable length for use in non hazardous area Ex Zone 2 Class...

Страница 36: ...Density liquids 0 2 kg m 0 0002 g cm Valid between 20 C and 60 C The measured error increases by 0 015 kg m3 C outside the temperature range Valid range for density calibration 0 to 2000 kg m 20 to 6...

Страница 37: ...racy specifications Current output Accuracy 5 A Pulse frequency output o r of reading Accuracy Max 50 ppm o r across the entire ambient temperature range Repeatability o r of reading 1 g cm3 1 kg l T...

Страница 38: ...density calibration temperature and the process temperature the typical measured error of the sensor is 0 015 kg m3 C 0 0075 kg m3 F kg m 3 0 0 5 1 0 1 5 2 0 2 5 3 0 C F 200 150 100 50 0 50 100 150 2...

Страница 39: ...00 A0021332 BaseAccu A0021339 ZeroPoint BaseAccu 100 A0021333 ZeroPoint MeasValue 100 A0021334 Calculation of the maximum repeatability as a function of the flow rate Flow rate Maximum repeatability i...

Страница 40: ...al pipeline Pipe restrictions or the use of an orifice with a smaller cross section than the nominal diameter prevent the sensor running empty while measurement is in progress 1 2 3 4 5 A0028773 17 In...

Страница 41: ...rved measuring tube 1 Avoid this orientation for fluids with entrained solids Risk of solids accumulating 2 Avoid this orientation for outgassing fluids Risk of gas accumulating Inlet and outlet runs...

Страница 42: ...erence conditions 36 Therefore a zero point adjustment in the field is generally not required Experience shows that zero point adjustment is advisable only in special cases To achieve maximum measurin...

Страница 43: ...ather protection cover from Endress Hauser 81 Storage temperature 50 to 80 C 58 to 176 F Climate class DIN EN 60068 2 38 test Z AD Degree of protection Transmitter and sensor As standard IP66 67 type...

Страница 44: ...to 205 C 58 to 401 F Low temperature 196 to 150 C 320 to 302 F Order code for Measuring tube material option LA TA TF B A A0031121 TA Ambient temperature TF Medium temperature A Maximum permissible m...

Страница 45: ...2 1 DIN 2501 PN100 PN63 PN40 PN16 0 10 20 30 40 50 60 70 80 90 100 0 200 400 600 800 1200 1300 1400 bar psi 0 80 160 240 320 400 C F 200 150 100 50 0 50 200 100 320 80 A0029636 EN 19 With flange mater...

Страница 46: ...th the device order code for Additional Approval option LN Type test containment DN Secondary containment pressure rating designed with a safety factor 4 Secondary containment burst pressure mm in bar...

Страница 47: ...82 System pressure It is important that cavitation does not occur or that gases entrained in the liquids do not outgas This is prevented by means of a sufficiently high system pressure For this reason...

Страница 48: ...bility of the measuring system is not affected by plant vibrations Custody transfer measurement The measuring device is optionally tested in accordance with OIML R81 R117 and has an EC evaluation cert...

Страница 49: ...up to 30 mm 3 dependent on respective process connection Order code for Housing option A Aluminum coated Ex d DN A 1 B 1 C D 2 E 2 F G H I K L mm mm mm mm mm mm mm mm mm mm mm mm 25 200 141 59 169 68...

Страница 50: ...382 790 408 2 80 200 141 59 169 68 101 43 5 409 933 524 2 100 200 141 59 169 68 101 68 9 435 1090 655 2 1 Depending on the cable gland used values up to 30 mm 2 Dependent on the respective process co...

Страница 51: ...82 5 840 100 235 190 8 22 24 107 1 1128 Surface roughness flange EN 1092 1 Form B1 DIN 2526 Form C Ra 3 2 to 12 5 m Flange according to EN 1092 1 DIN 2501 PN 40 with reduction in nominal diameter 1 44...

Страница 52: ...25 110 79 4 4 15 7 14 2 26 7 440 50 150 120 7 4 19 1 19 1 52 6 715 80 190 152 4 4 19 1 23 9 78 0 840 100 230 190 5 8 19 1 23 9 102 4 1128 Surface roughness flange Ra 3 2 to 6 3 m Flange according to A...

Страница 53: ...m B mm C mm D mm E mm L mm 25 125 88 9 4 19 1 23 9 24 3 490 50 165 127 8 19 1 31 8 49 2 742 80 210 168 3 8 22 2 40 0 73 7 900 100 275 215 9 8 25 4 48 4 97 3 1158 Surface roughness flange Ra 3 2 to 6 3...

Страница 54: ...165 130 8 19 26 50 760 80 210 170 8 23 32 75 890 100 250 205 8 25 36 100 1168 Surface roughness flange Ra 1 6 to 3 2 m Flange JIS B2220 63K 1 4404 F316 F316L Order code for Process connection option...

Страница 55: ...12 81 900 100 159 137 8 11 14 100 1128 3A version available order code for Additional approval option LP in conjunction with Ra 0 8 m Order code for Measuring tube material option SB Flange DIN11864 2...

Страница 56: ...on LP in conjunction with Ra 0 8 m Order code for Measuring tube material option SB Tri Clamp 1 for pipe according to DIN 11866 series C with nominal diameter reduction 1 4404 316L Order code for Proc...

Страница 57: ...l option LP in conjunction with Ra 0 8 m Order code for Measuring tube material option SB Threaded hygienic connection DIN11864 1 Form A for pipe according to DIN11866 series A 1 4404 316 316L Order c...

Страница 58: ...Measuring tube material option SB Accessories Purge connections pressure monitoring of secondary containment rupture disk L 45 A SW 1 2 NPT 1 NPT 35 1 38 ca 75 approx 2 95 1 1 2 A A0030349 23 Enginee...

Страница 59: ...s Hauser 59 Remote display and operating module DKX001 136 5 35 114 4 49 86 3 39 78 3 07 103 4 06 12 0 47 7 0 0 27 A0028921 24 Engineering unit mm in External WLAN antenna 68 2 7 93 3 6 161 6 3 A00289...

Страница 60: ...dent on respective process connection Order code for Housing option A Aluminum coated Ex d DN A 1 B C D 2 E F G H I K L in in in in in in in in in in in in 1 7 87 5 55 2 32 6 65 2 68 3 98 0 60 14 23 2...

Страница 61: ...4 23 22 78 8 54 2 2 7 87 5 55 2 32 6 65 2 68 3 98 1 10 15 04 31 10 16 06 2 3 7 87 5 55 2 32 6 65 2 68 3 98 1 71 16 10 36 73 20 63 2 4 7 87 5 55 2 32 6 65 2 68 3 98 2 71 17 13 42 91 25 79 2 1 Depending...

Страница 62: ...28 15 3 8 27 6 63 8 0 88 1 12 3 07 33 07 4 10 04 7 87 8 0 88 1 25 4 03 44 41 Surface roughness flange Ra 125 to 248 in Flange according to ASME B16 5 Class 600 1 4404 F316 F316L Order code for Proces...

Страница 63: ...option LP in conjunction with Ra 32 in Order code for Measuring tube material option SB Tri Clamp 1 for pipe according to DIN 11866 series C with nominal diameter reduction 1 4404 316L Order code for...

Страница 64: ...04 45 12 3A version available order code for Additional approval option LP in conjunction with Ra 32 in Order code for Measuring tube material option SB Accessories Purge connections pressure monitori...

Страница 65: ...4 06 12 0 47 7 0 0 27 A0028921 27 Engineering unit mm in External WLAN antenna 68 2 7 93 3 6 161 6 3 A0028923 28 Engineering unit mm in Weight All values weight refer to devices with EN DIN PN 40 flan...

Страница 66: ...Aluminum coated glass Option L Cast stainless glass Cable entries cable glands 1 2 3 4 A0028352 29 Possible cable entries cable glands 1 Cable entry with M20 1 5 internal thread 2 Cable gland M20 1 5...

Страница 67: ...Plug M12 1 Socket Stainless steel 1 4404 316L Contact housing Polyamide Contacts Gold plated brass Device plug Electrical connection Material Plug M12x1 Socket Stainless steel 1 4404 316L Contact hous...

Страница 68: ...n via the integrated memory integrated HistoROM which contains the process and measuring device data and the event logbook No need to reconfigure Efficient diagnostics increase measurement availabilit...

Страница 69: ...10 m 30 ft Cable touch control Another device version e g other housing material other cable length etc can be ordered via the separate product structure DKX001 The measuring device is ordered with O...

Страница 70: ...ousing order code for Electrical connection Connecting cable 35 Dimensions 59 Remote operation Via HART protocol This communication interface is available in device versions with a HART output 1 2 3 5...

Страница 71: ...Care AMS Device Manager SIMATIC PDM with COM DTM CDI Communication TCP IP 6 Commubox FXA195 USB 7 Field Xpert SFX350 or SFX370 8 VIATOR Bluetooth modem with connecting cable 9 Transmitter Via FOUNDATI...

Страница 72: ...ment coupler PROFIBUS DP PA 5 PROFIBUS PA network 6 T box 7 Measuring device Via Modbus RS485 protocol This communication interface is available in device versions with a Modbus RS485 output 1 2 3 A00...

Страница 73: ...ontrol WLAN 2 1 5 6 3 4 3 4 A0028839 1 Transmitter with integrated WLAN antenna 2 Transmitter with external WLAN antenna 3 LED lit constantly WLAN reception is enabled on measuring device 4 LED flashi...

Страница 74: ...ield Device Manager FDM by Honeywell www honeywellprocess com FieldMate by Yokogawa www yokogawa com PACTWare www pactware com The associated device description files are available at www endress com...

Страница 75: ...or plug in the transmitter neck part Data backup Automatic The most important device data sensor and transmitter are automatically saved in the DAT modules If the transmitter or measuring device is re...

Страница 76: ...nts of the applicable EU Directives These are listed in the corresponding EU Declaration of Conformity along with the standards applied Endress Hauser confirms successful testing of the device by affi...

Страница 77: ...A Class I Zone 2 AEx Ex nA IIC T5 T1 Gc Ex tb Zone 21 AEx Ex tb IIIC T C Db Sanitary compatibility 3 A approval EHEDG tested Functional safety The measuring device can be used for flow monitoring syst...

Страница 78: ...ures carried out Radio approval Europe RED 2014 53 EU United States of America CFR Title 47 FCC Part 15 247 Canada RSS 247 Issue 1 Japan Article 2 clause 1 item 19 Additional country specific approval...

Страница 79: ...with Class A requirements Electromagnetic compatibility EMC requirements NAMUR NE 21 Electromagnetic compatibility EMC of industrial process and laboratory control equipment NAMUR NE 32 Data retentio...

Страница 80: ...cription Extended HistoROM Comprises extended functions concerning the event log and the activation of the measured value memory Event log Memory volume is extended from 20 message entries standard ve...

Страница 81: ...ccessories Description Transmitter Promass 300 Transmitter for replacement or storage Use the order code to define the following specifications Approvals Output Input Display operation Housing Softwar...

Страница 82: ...ions BA01202S Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance It enables efficient device configuration and diagnostics for HART and FOUNDATION Fieldbus de...

Страница 83: ...read in the operating pressure value For details see Technical Information TI00426P TI00436P and Operating Instructions BA00200P BA00382P Cerabar S The pressure transmitter for measuring the absolute...

Страница 84: ...IECEx Ex d Ex de XA01405D ATEX IECEx Ex ec XA01439D cCSAus XP XA01373D cCSAus Ex d Ex de XA01372D cCSAus Ex nA XA01507D INMETRO Ex d Ex de XA01468D INMETRO Ex ec XA01470D NEPSI Ex d Ex de XA01469D NEP...

Страница 85: ...transfer SD01688D SD01689D Installation Instructions Contents Documentation code Installation Instructions for spare part sets Specified for each individual accessory Registered trademarks HART Regis...

Страница 86: ......

Страница 87: ......

Страница 88: ...www addresses endress com...

Отзывы: