Proline Promass O 100 HART
Installation
Hauser
19
DN
Ø orifice plate, pipe restriction
[mm]
[in]
[mm]
[in]
Orientation
The direction of the arrow on the sensor nameplate helps you to install the sensor
according to the flow direction (direction of medium flow through the piping).
Orientation
Recommendation
A
Vertical orientation
A0015591
B
Horizontal orientation, transmitter
head up
A0015589
Exception:
C
Horizontal orientation, transmitter
head down
A0015590
Exception:
D
Horizontal orientation, transmitter
head at side
A0015592
1)
Applications with low process temperatures may reduce the ambient temperature. To maintain the
minimum ambient temperature for the transmitter, this orientation is recommended.
2)
Applications with high process temperatures may increase the ambient temperature. To maintain the
maximum ambient temperature for the transmitter, this orientation is recommended.
If a sensor is installed horizontally with a curved measuring tube, match the position of the
sensor to the fluid properties.
1
2
A0014057
5
Orientation of sensor with curved measuring tube
1
Avoid this orientation for fluids with entrained solids: Risk of solids accumulating.
2
Avoid this orientation for outgassing fluids: Risk of gas accumulating.
Содержание Proline Promass O 100HART
Страница 140: ...www addresses endress com ...