Proline Promass F 300 EtherNet/IP
Diagnostics and troubleshooting
201
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
383 Memory content
1. Restart device
2. Delete T-DAT via 'Reset device'
parameter
3. Replace T-DAT
0x100016E
Status signal
F
Diagnostic behavior
Alarm
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
387 HistoROM backup failed
Contact service organization
0x1000288
Status signal
F
Diagnostic behavior
Alarm
12.8.3 Diagnostic of configuration
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
303 I/O 1 to n configuration changed
1. Apply I/O module configuration
(parameter 'Apply I/O
configuration')
2. Afterwards reload device
description and check wiring
0x400026C
Status signal
M
Diagnostic behavior
Warning
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
330 Flash file invalid
1. Update firmware of device
2. Restart device
0x40002C9
Status signal
M
Diagnostic behavior
Warning
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
331 Firmware update failed
1. Update firmware of device
2. Restart device
0x10002CA
Status signal
F
Diagnostic behavior
Warning
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
410 Data transfer
1. Check connection
2. Retry data transfer
0x100008B
Status signal
F
Diagnostic behavior
Alarm
Содержание Proline Promass F 300