Proline Promag P 200
Hauser
25
Pressure tightness
Liner: PFA
Nominal diameter
Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures:
[mm]
[in]
+25 °C (+77 °F)
+80 °C (+176 °F)
+100 to +180 °C (+212 to
+356 °F)
25
1
0 (0)
0 (0)
0 (0)
32
–
0 (0)
0 (0)
0 (0)
40
1 ½
0 (0)
0 (0)
0 (0)
50
2
0 (0)
0 (0)
0 (0)
65
–
0 (0)
– (–)
0 (0)
80
3
0 (0)
– (–)
0 (0)
100
4
0 (0)
– (–)
0 (0)
125
–
0 (0)
– (–)
0 (0)
150
6
0 (0)
– (–)
0 (0)
200
8
0 (0)
– (–)
0 (0)
Liner: PTFE
Nominal diameter
Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures:
[mm]
[in]
+25 °C (+77 °F)
+80 °C (+176 °F)
+100 °C (+212 °F) +130 °C (+266 °F)
15
½
0 (0)
0 (0)
0 (0)
100 (1.45)
25
1
0 (0)
0 (0)
0 (0)
100 (1.45)
32
–
0 (0)
0 (0)
0 (0)
100 (1.45)
40
1 ½
0 (0)
0 (0)
0 (0)
100 (1.45)
50
2
0 (0)
0 (0)
0 (0)
100 (1.45)
65
–
0 (0)
– (–)
40 (0.58)
130 (1.89)
80
3
0 (0)
– (–)
40 (0.58)
130 (1.89)
100
4
0 (0)
– (–)
135 (1.96)
170 (2.47)
125
–
135 (1.96)
– (–)
240 (3.48)
385 (5.58)
150
6
135 (1.96)
– (–)
240 (3.48)
385 (5.58)
200
8
200 (2.90)
– (–)
290 (4.21)
410 (5.95)
Flow limit
The diameter of the pipe and the flow rate determine the nominal diameter of the sensor. The optimum velocity
of flow is between 2 to 3 m/s (6.56 to 9.84 ft/s). Also match the velocity of flow (v) to the physical properties
of the fluid:
• v
<
2 m/s (6.56 ft/s): for abrasive fluids (e.g. potter's clay, lime milk, ore slurry)
• v
>
2 m/s (6.56 ft/s): for fluids producing buildup (e.g. wastewater sludges)
For an overview of the measuring range full scale values, see the "Measuring range" section (
Pressure loss
• No pressure loss occurs if the sensor is installed in a pipe with the same nominal diameter.
• Pressure losses for configurations incorporating adapters according to DIN EN 545 (
System pressure
• Never install the sensor on the pump suction side in order to avoid the risk of low pressure, and thus damage
to the liner.
• Furthermore, install pulse dampers if reciprocating, diaphragm or peristaltic pumps are used.
• For information on the liner's resistance to partial vacuum (
• For information on the measuring system's resistance to vibration and shock (