Description of device parameters
Proline Promag 300 Modbus RS485
76
Hauser
"Low flow cut off" submenu
Navigation
Expert → Sensor → Process param. → Low flow cut off
‣
Low flow cut off
Assign variable (1837)
On value (1805)
Off value (1804)
Pres. shock sup. (1806)
Assign variable
Navigation
Expert → Sensor → Process param. → Low flow cut off → Assign variable (1837)
Description
Use this function to select the process variable for low flow cutoff detection.
Selection
• Off
• Volume flow
• Mass flow
• Correct.vol.flow
Factory setting
Volume flow
On value
Navigation
Expert → Sensor → Process param. → Low flow cut off → On value (1805)
Prerequisite
One of the following options is selected in the
Assign variable
• Volume flow
• Mass flow
Description
Use this function to enter a switch-on value for low flow cut off. Low flow cut off is
activated if the value entered is not equal to 0 → 77.
User entry
Positive floating-point number
Factory setting
Depends on country and nominal diameter→ 213
Additional information
Dependency
The unit depends on the process variable selected in the
Assign variable
parameter