Proline Cubemass C 500
Hauser
15
Output
Output and input variants
Depending on the option selected for output/input 1, different options are available for the other
outputs and inputs. Only one option can be selected for each output/input 1 to 4. The table must be
read vertically (↓).
Example: If the option BA "4–20 mA HART" was selected for output/input 1, one of the options A, B,
D, E, F, H, I or J is available for output 2, and one of the options A, B, D, E, F, H, I or J is available for
output 3 and 4.
Order code for "Output; input 1" (020) →
Possible options
Current output 4 to 20 mA HART
BA
Current output 4 to 20 mA HART Ex i
↓
CA
FOUNDATION Fieldbus
↓
SA
FOUNDATION Fieldbus Ex i
↓
TA
PROFIBUS DP
↓
LA
PROFIBUS PA
↓
GA
PROFIBUS PA Ex i
↓
HA
Modbus RS485
↓
MA
EtherNet/IP 2-port switch integrated
↓
NA
PROFINET 2-port switch integrated
↓
RA
Order code for "Output; input 2" (021) →
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
Not assigned
A
A
A
A
A
A
A
A
A
A
Current output 0/4 to 20 mA
B
B
B
B
B
B
B
Current output 0/4 to 20 mA (Ex i)
C
C
C
User configurable input/output
D
D
D
D
D
D
D
Pulse/frequency/switch output
E
E
E
E
E
E
E
Double pulse output
F
F
Pulse/frequency/switch output (Ex i)
G
G
G
Relay output
H
H
H
H
H
H
H
Current input 0/4 to 20 mA
I
I
I
I
I
I
I
Status input
J
J
J
J
J
J
J
Order code for "Output; input 3" (022), "Output; input 4" (023)
→
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
Not assigned
A
A
A
A
A
A
A
A
A
A
Current output 0/4 to 20 mA
B
B
B
B
B
Current output 0/4 to 20 mA (Ex i)
C
User configurable input/output
D
D
D
D
D
Pulse/frequency/switch output
E
E
E
E
E
Double pulse output (slave)
F
F
Pulse/frequency/switch output (Ex i)
G
Relay output
H
H
H
H
H
Current input 0/4 to 20 mA
I
I
I
I
I
Status input
J
J
J
J
J
1)
A specific input or output can be assigned to a user configurable input/output → 19.
2)
If double pulse output (F) is selected for output/input 2 (021), only the double pulse output (F) option is available for selection for output/input 3
(022).
3)
The order code for "Output; input 4" (023) is only available for the Proline 500 – digital transmitter.
4)
The double pulse output (F) option is not available for input/output 4.
Заказывайте
на
сайте
: www.tinnova.ru/endress_hauser/ ||
Эл
.
почта