Level measurement in liquids

Application

• Continuous, non-contact level measurement of liquids,

pastes and sludges

• PTFE drip-off antenna

• Maximum measuring range: 50 m (164 ft)

• Temperature: –40 to +130 °C (–40 to +266 °F)

• Pressure: –1 to +16 bar (–14.5 to +232 psi)

• Accuracy: ± 1 mm (0.04 in)

• Linearity protocol (3-point, 5-point)

Your benefits

• Innovative drip-off antenna made of PTFE

• Reliable measurement thanks to improved focusing and small beam angle,

particularly in vessels with many internal fittings

• Safety by design - ensures highest safety

• Easy, guided commissioning with intuitive user interface

Bluetooth

® wireless technology for commissioning, operation and maintenance via

free iOS / Android app SmartBlue

• Maximum reliability thanks to multi-echo tracking

• HistoROM configuration memory makes for easier commissioning,

maintenance and diagnostics

• SIL2 as per IEC 61508, SIL3 for homogeneous or diverse redundancy

• Easy proof testing for SIL and WHG

• RFID TAG - easy identification of measuring points for improved data access

• Heartbeat Technology

Products

Solutions

Services

Technical Information

Micropilot FMR60

Free space radar

TI01302F/00/EN/04.18

71394723

Содержание Micropilot FMR60

Страница 1: ...rly in vessels with many internal fittings Safety by design ensures highest safety Easy guided commissioning with intuitive user interface Bluetooth wireless technology for commissioning operation and maintenance via free iOS Android app SmartBlue Maximum reliability thanks to multi echo tracking HistoROM configuration memory makes for easier commissioning maintenance and diagnostics SIL2 as per I...

Страница 2: ...ent temperature range 30 Ambient temperature limits 30 Storage temperature 31 Climate class 31 Altitude according to IEC61010 1 Ed 3 31 Degree of protection 31 Vibration resistance 31 Electromagnetic compatibility EMC 31 Process 32 Process temperature process pressure 32 Dielectric constant 33 Mechanical construction 34 Dimensions 34 Weight 37 Materials GT19 housing plastic 38 Materials GT20 housi...

Страница 3: ... V 4 Rev 2 19 03 2018 3 Heartbeat Verification 60 Heartbeat Monitoring 61 Accessories 62 Device specific accessories 62 Communication specific accessories 66 Service specific accessories 67 System components 67 Supplementary documentation 68 Standard documentation 68 Safety Instructions XA 68 ...

Страница 4: ... Alternating current Direct current and alternating current Ground connection A grounded terminal which as far as the operator is concerned is grounded via a grounding system Protective Earth PE A terminal which must be connected to ground prior to establishing any other connections The ground terminals are situated inside and outside the device Inner ground terminal Connects the protectiv earth t...

Страница 5: ...rea Indicates a hazardous area Safe area non hazardous area Indicates the non hazardous area Symbols at the device Symbol Meaning Safety instructions Observe the safety instructions contained in the associated Operating Instructions Temperature resistance of the connection cables Specifies the minimum value of the temperature resistance of the connection cables ...

Страница 6: ...The MWP can also be found on the nameplate ToF Time of Flight FieldCare Scalable software tool for device configuration and integrated plant asset management solutions DeviceCare Universal configuration software for Endress Hauser HART PROFIBUS FOUNDATION Fieldbus and Ethernet field devices DTM Device Type Manager DD Device Description for HART communication protocol DC Relative dielectric constan...

Страница 7: ...se of such marks by Endress Hauser is under license Other trademarks and trade names are those of their respective owners Apple Apple the Apple logo iPhone and iPod touch are trademarks of Apple Inc registered in the U S and other countries App Store is a service mark of Apple Inc Android Android Google Play and the Google Play logo are trademarks of Google Inc KALREZ VITON Registered trademark of...

Страница 8: ...tance between reference point and product surface The frequency of this wave is modulated in the form of a sawtooth signal between two limit frequencies f1 and f2 f t 1 2 f2 f1 t f A0023771 2 FMCW principle result of frequency modulation 1 Transmitted signal 2 Received signal This results in the following difference frequency at any time between the transmitted signal and the received signal Δf k ...

Страница 9: ...n and any possible interference reflections The following tables describe the groups of media as well as the achievable measuring range as a function of application and media group If the dielectric constant of a medium is unknown it is recommended to assume media group B to ensure a reliable measurement Media groups Media group DC εr Example A0 1 2 to 1 4 Butane liquid nitrogen liquefied hydrogen...

Страница 10: ...ving surfaces e g continuous filling from above mixing jets A0034567 Turbulent surface e g filling from above agitators baffles A0 A B C D 7 23 12 39 23 75 40 131 50 164 A0034574 A0 A B C D 4 13 7 23 13 43 28 92 44 144 A0034579 A0 A B C D 2 7 4 13 7 23 15 49 25 82 A0034584 Measuring range m ft Operating frequency Approx 80 GHz Up to 8 devices can be installed in the same tank without interfering w...

Страница 11: ...ing output Switching behavior Binary conductive or non conductive switches when the programmable switch point is reached Failure mode non conductive Electrical connection values U 16 to 35 VDC I 0 to 40 mA Internal resistance RI 880 Ω The voltage drop at this internal resistance has to be taken into account on planning the configuration For example the resulting voltage at a connected relay must b...

Страница 12: ... of up to 32 value pairs can be entered manually or semi automatically Galvanic isolation All circuits for the outputs are galvanically isolated from each other Protocol specific data HART Manufacturer ID 17 0x11 Device type ID 0x112B HART specification 7 0 Device description files DTM DD Information and files under www endress com www fieldcommgroup org HART load min 250 Ω HART device variables T...

Страница 13: ...DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT Micropilot FMR60 Endress Hauser V 4 Rev 2 19 03 2018 13 Multidrop current 4 0 mA Set up time 15 s ...

Страница 14: ...294 3 Terminal assignment 2 wire 4 20mA HART A Without integrated overvoltage protection B With integrated overvoltage protection 1 Active barrier with power supply e g RN221N Observe terminal voltage 2 HART communication resistor 250 Ω Observe maximum load 3 Connection for Commubox FXA195 or FieldXpert SFX350 SFX370 via VIATOR Bluetooth modem 4 Analog display device Observe maximum load 5 Cable s...

Страница 15: ...tch output A Without integrated overvoltage protection B With integrated overvoltage protection 1 Active barrier with power supply e g RN221N Observe terminal voltage 2 HART communication resistor 250 Ω Observe maximum load 3 Connection for Commubox FXA195 or FieldXpert SFX350 SFX370 via VIATOR Bluetooth modem 4 Analog display device Observe maximum load 5 Cable screen observe cable specification ...

Страница 16: ...output 2 2 Connection current output 1 3 Supply voltage for current output 1 e g RN221N Observe terminal voltage 4 Cable screen observe cable specification 5 HART communication resistor 250 Ω Observe maximum load 6 Connection for Commubox FXA195 or FieldXpert SFX350 SFX370 via VIATOR Bluetooth modem 7 Analog display device observe maximum load 8 Analog display device observe maximum load 9 Supply ...

Страница 17: ... B 2 wire 4 20mA HART switch output 3 4 Ri A0015909 6 Connection of a relay Suitable relays examples Solid state relay Phoenix Contact OV 24DC 480AC 5 with mounting rail connector UMK 1 OM R AMS Electromechanical relay Phoenix Contact PLC RSC 12DC 21 3 2 1 4 Ri A0015910 7 Connection of a digital input 1 Pull up resistor 2 Digital input For optimum interference immunity we recommend to connect an e...

Страница 18: ...or the versions with fieldbus plug connector M12 or 7 8 the signal line can be connected without opening the housing Pin assignment of the M12 plug connector 2 1 3 4 A0011175 Pin Meaning 1 Signal 2 not connected 3 Signal 4 Ground Pin assignment of the 7 8 plug connector 4 2 3 1 A0011176 Pin Meaning 1 Signal 2 Signal 3 Not connected 4 Screen ...

Страница 19: ...Ex d ia IS XP 14 to 30 V 3 1 Feature 020 in the product structure 2 Feature 010 in the product structure 3 If the Bluetooth modem is used the minimum supply voltage increases by 2 V 4 At ambient temperatures TTa 20 C a terminal voltage U 16 V is required to start the device with the min error current 3 6 mA Power supply output 1 Approval 2 Terminal voltage U at device Maximum load R depending on t...

Страница 20: ...V Permitted residual ripple with f 100 to 10000 Hz USS 10 mV Power consumption Power supply Output 1 Power consumption A 2 wire 4 20mA HART 0 9 W B 2 wire 4 20mA HART switch output 0 9 W C 2 wire 4 20mA HART 4 20mA 2 x 0 7 W 1 Feature 020 of the product structure Current consumption HART Nominal current 3 6 to 22 mA the start up current for multidrop mode can be parametrized is set to 3 6 mA on de...

Страница 21: ...to 2 5 mm2 24 to 14 AWG For ambient temperature TU 60 C 140 F use cable for temperature TU 20 K HART A normal device cable suffices if only the analog signal is used A shielded cable is recommended if using the HART protocol Observe grounding concept of the plant Overvoltage protection If the measuring device is used for level measurement in flammable liquids which requires the use of overvoltage ...

Страница 22: ...ero point arising from the mounting conditions may be up to 4 mm 0 16 in This additional offset zero point can be compensated for by entering a correction parameter level correction during commissioning 3 The non repeatability is already considered in the accuracy Differing values in near range applications 0 8 2 62 4 0 16 1 0 04 1 0 04 4 0 16 D m mm in R 0 A0032636 8 Maximum measured error in nea...

Страница 23: ...nd its temperature This results in a systematic measured error that increases with increasing distance between the reference point of the measurement flange and the surface of the product The following table shows this measured error for a few typical gases vapors with regard to the distance a positive value means that a too large distance is measured Gas phase Temperature Pressure C F 1 bar 14 5 ...

Страница 24: ...882 Recommended distance A wall nozzle outer edge 1 6 of the container diameter However the device must not under any circumstances be mounted closer than 15 cm 5 91 in to the tank wall Not in the center 2 as interference can cause signal loss Not above the filling curtain 3 The use of a weather protection cover 1 is recommended to protect the transmitter from direct sunlight or rain ...

Страница 25: ...ilot FMR60 Endress Hauser V 4 Rev 2 19 03 2018 25 Internal container fittings α A0031777 Avoid the location of internal fittings limit switches temperature sensors struts vacuum rings heating coils baffles etc inside the signal beam Take into account the beam angle 26 ...

Страница 26: ...the smaller the beam angle α resulting in fewer interference echoes 26 Mapping Measurement can be optimized by electronically suppressing interference echoes Beam angle D W D _ 2 2 tan W α α A0031824 9 Relationship between beam angle α distance D and beamwidth diameter W The beam angle is defined as the angle α where the energy density of the radar waves reaches half the value of the maximum energ...

Страница 27: ... 89 ft 25 m 82 ft 2 62 m 8 60 ft 30 m 98 ft 3 14 m 10 30 ft 35 m 115 ft 3 67 m 12 04 ft 40 m 131 ft 4 19 m 13 75 ft 45 m 148 ft 4 72 m 15 49 ft 50 m 164 ft 5 24 m 17 19 ft 1 Feature 070 in the product structure Measurement through a ball valve A0034564 Measurements can be performed through an open full bore ball valve without any problems At the transitions no gap may be left exceeding 1 mm 0 04 i...

Страница 28: ...rspex DK εr 2 3 2 1 2 3 3 1 Optimum thickness 1 25 mm 0 049 in 1 1 3 mm 0 051 1 1 25 mm 0 049 in 1 1 07 mm 0 042 in 1 1 or an integer multiple of this value however take into account that the microwave transparency is significantly reduced when increasing the thickness of the window Installation Drip off antenna PTFE 50 mm 2 Aligning the antenna axis Align the antenna vertically to the product sur...

Страница 29: ... The edge of the nozzle should be rounded if possible Mapping must be performed Please contact Endress Hauser for applications with nozzles that are higher than indicated in the table Information concerning threaded connections When screwing in turn by the hex bolt only Tool open ended wrench 55 mm Maximum permissible torque 50 Nm 36 lbf ft Container with heat insulation 1 2 A0032207 If process te...

Страница 30: ...he following diagram temperature derating in the table header FMR60 P2 P1 P5 P4 P3 Ta Tp A0032024 Seal 1 A3 FKM Viton GLT 40 to 80 C 40 to 176 F Temperature specifications C F Housing type 2 P1 P2 P3 P4 P5 Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta A GT19 two chamber Plastic PBT 40 40 60 140 60 140 60 140 80 176 54 129 2 80 176 40 40 40 40 40 40 C GT20 two chamber Aluminum coated 40 40 76 168 8 76 168 8 76 168...

Страница 31: ...ROFIBUS cable is plugged in and is also rated IP68 NEMA6P Vibration resistance DIN EN 60068 2 64 IEC 60068 2 64 at 5 to 2000 Hz 1 5 m s2 2 Hz Electromagnetic compatibility EMC Electromagnetic compatibility in accordance with all of the relevant requirements outlined in the EN 61326 series and NAMUR Recommendation EMC NE 21 For details please refer to the Declaration of Conformity 4 A normal device...

Страница 32: ...property the materials 1 4435 and 1 4404 are grouped in EN 1092 1 table 18 under 13E0 The chemical composition of the two materials can be identical ASME B 16 5a 1998 Tab 2 2 2 F316 ASME B 16 5a 1998 Tab 2 3 8 N10276 JIS B 2220 FMR60 threaded process connection p 40 40 130 266 0 32 Tp C F 1 bar psi 16 232 1 14 5 0 0 A0032614 10 FMR60 Permitted range for process temperature and process pressure 1 F...

Страница 33: ...nge 3 DN80 80A PP XKG UNI flange 4 DN100 100A PP XLG UNI flange 6 DN150 150A PP 40 to 80 C 40 to 176 F prel 1 to 3 bar 14 5 to 43 5 psi pabs 4 bar 58 psi 1 XJJ UNI flange 3 DN80 80A 316L XKJ UNI flange4 DN100 100A 316L XLJ UNI flange 6 DN150 150A 316L 40 to 130 C 40 to 266 F 1 The pressure range may be further restricted in the event of a CRN approval Dielectric constant For liquids εr 1 9 Please ...

Страница 34: ...ing 144 5 67 113 5 4 47 ø106 4 17 78 3 07 90 3 54 99 3 9 ø 1 0 6 4 1 7 R110 A0011346 12 Housing GT19 Plastics PBT Dimensions in mm in for devices with integrated overvoltage protection 145 5 5 73 141 5 5 57 ø112 4 41 ø108 5 4 27 78 3 07 90 3 54 98 3 86 ø 1 0 3 5 4 0 7 R110 61 2 4 A0020751 13 Housing GT20 Alu coated Dimensions in mm in for devices with integrated overvoltage protection ...

Страница 35: ... 35 FMR60 Antenna and process connection A B ø42 5 1 67 ø42 5 1 67 205 8 07 78 3 07 127 5 00 22 0 87 107 4 21 R 1 1 A0031560 14 Dimensions mm in A Process connection G1 1 2 or MNPT1 1 2 thread B Process connection UNI flange 3 DN80 80A to 6 DN150 150A R Reference point of the measurement 1 Bottom edge of housing ...

Страница 36: ...B C D XJG UNI flange 3 DN80 80A PP XJJ UNI flange 3 DN80 80A 316L 3 150lbs DN80 PN16 10K 80A 150 mm 5 9 in 160 mm 6 3 in 200 mm 7 9 in 19 mm 0 75 in XKG UNI flange 4 DN100 100A PP XKJ UNI flange 4 DN100 100A 316L 4 150lbs DN100 PN16 10K 100A 175 mm 6 9 in 190 5 mm 7 5 in 228 6 mm 9 in 19 mm 0 75 in XLG UNI flange 6 DN150 150A PP XLJ UNI flange 6 DN150 150A 316L 6 150lbs DN150 PN16 10K 150A 240 mm ...

Страница 37: ...ing Part Weight GT19 housing plastic Approx 1 2 kg 2 7 lb GT20 housing aluminum Approx 1 9 kg 4 2 lb Antenna and process connection Device Antenna 1 Weight of antenna process connection FMR60 GA Drip off PTFE DN50 Max 2 kg 4 41 lb flange weight 2 1 Order code 070 2 For flange weights 316 316L see Technical Information TI00426F ...

Страница 38: ...rsion PE PBT GF Cable gland depending on the device version Nickel plated brass CuZn PA Adapter 316L 1 4404 1 4435 Seal EPDM M12 plug Nickel plated brass 1 7 8 plug 316 1 4401 2 5 2 Dummy plug cable gland or adapter depending on the device version Dummy plug depending on the device version PE PBT GF Nickel plated steel Cable gland depending on the device version Nickel plated brass CuZn PA Adapter...

Страница 39: ...ver lock Screw A4 Clamp 316L 1 4404 4 Lock at the housing neck Screw A4 70 Clamp 316L 1 4404 5 1 Dummy plug cable gland adapter or plug depending on the device version Dummy plug depending on the device version PE PBT GF Cable gland depending on the device version Nickel plated brass CuZn PA Adapter 316L 1 4404 1 4435 Seal EPDM M12 plug Nickel plated brass 1 7 8 plug 316 1 4401 2 5 2 Dummy plug ca...

Страница 40: ... 4301 9 Adhesive nameplate Plastic 1 For the version with M12 plug the sealing material is Viton 2 For the version with 7 8 plug the sealing material is NBR Materials antenna and process connection FMR60 1 2 3 4 5 A0031812 No Component part Material 1 Antenna Antenna PTFE Antenna seal Viton FKM 2 Antenna adapter 316L 1 4404 3 Housing adapter 316L 1 4404 4 Housing seal EPDM 5 Process connection 316...

Страница 41: ...1 Materials Weather protection cover 1 2 3 4 5 6 A0015473 No Part Material 1 Protection cover 316L 1 4404 2 Molded rubber part 4x EPDM 3 Clamping screw 316L 1 4404 carbon fibre 4 Bracket 316L 1 4404 5 Ground terminal Screw A4 Spring washer A4 Clamp 316L 1 4404 Holder 316L 1 4404 6 Washer A4 Cheese head screw A4 70 ...

Страница 42: ...idance with brief explanations of the individual parameter functions Standardized operation at the device and in the operating tools Integrated data storage device HistoROM Enables transfer of configuration when changing electronic modules Records up to 100 event messages in the device Records up to 1000 measured values in the device Saves the signal curve on commissioning which can later be used ...

Страница 43: ... temperature range Operating elements local operation with 3 push buttons external operation via touch control 3 optical keys Operating elements also accessible in various hazardous areas Additional functionality Data backup function The device configuration can be saved in the display module Data comparison function The device configuration saved in the display module can be compared to the curre...

Страница 44: ...wireless technology Remote operation Via HART protocol 1 4 5 7 9 6 8 2 3 A0036169 18 Options for remote operation via HART protocol 1 PLC programmable logic controller 2 Transmitter power supply unit e g RN221N with communication resistor 3 Connection for Commubox FXA191 FXA195 and Field Communicator 375 475 4 Field Communicator 475 5 Computer with operating tool e g DeviceCare FieldCare AMS Devic...

Страница 45: ...user V 4 Rev 2 19 03 2018 45 DeviceCare FieldCare via service interface CDI 1 2 3 A0032466 19 DeviceCare FieldCare via service interface CDI 1 Service interface CDI of the instrument Endress Hauser Common Data Interface 2 Commubox FXA291 3 Computer with DeviceCare FieldCare operating tool ...

Страница 46: ... Event management Events such as when levels drop below the safety stock level or plan points are indicated by the software In addition SupplyCare can also notify pre defined users by e mail Alarms If technical problems occur e g connection issues alarms are triggered and alarm e mails are sent to the System Administrator and the Local System Administrator Delivery planning The integrated delivery...

Страница 47: ...latform with SupplyCare Enterprise SCE30B 1 SupplyCare Enterprise via Web browser 2 SupplyCare Enterprise installation 3 SupplyCare Enterprise on mobile devices via Web browser 4 Ethernet WLAN UMTS 5 Fieldgate FXA42 6 Power supply 24 V DC 7 Modbus TCP via Ethernet as server client 8 Converter from Modbus to HART Multidrop 9 HART Multidrop 10 4 x 4 to 20 mA analog input 2 wire 4 wire ...

Страница 48: ...et connection with FXA42 5 Fieldgate FXA42 6 Power supply 24 V DC 7 Modbus TCP via Ethernet as server client 8 Converter from Modbus to HART Multidrop 9 HART Multidrop 10 4 x 4 to 20 mA analog input 2 wire 4 wire With SupplyCare Hosting users do not need to make the initial software purchase or install and run the IT infrastructure needed Endress Hauser constantly update SupplyCare Hosting and enh...

Страница 49: ...ment included in the delivery Reference to the applicable XA can be found on the nameplate For details on the available certificates and associated XAs 68 Dual seal according to ANSI ISA 12 27 01 The devices have been designed according to ANSI ISA 12 27 01 as dual seal devices allowing the user to waive the use and save the cost of installing external secondary process seals in the conduit as req...

Страница 50: ... be located at a distance of 4 km from the astronomy stations listed below or otherwise approval must be provided by the relevant authority If the device is installed at a distance of 4 to 40 km from one of the listed stations it must not be installed at a height of more than 15 m 49 ft above the ground Astronomy stations Country Name of the station Latitude Longitude Germany Effelsberg 50 31 32 N...

Страница 51: ...areil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment The installation of the LPR TLPR device shall be don...

Страница 52: ...isted in this table Please refer to the product structure to discover which process connections are available for a specific device type CRN approved devices bear the registration number tbd on the nameplate An additional pressure restriction applies for the device versions listed in the table below if they are CRN approved The pressure range indicated in the Process section 32 continues to apply ...

Страница 53: ...spection certificates are available in electronic format in the W M Device Viewer Enter the serial number from nameplate www endress com deviceviewer This concerns the options for the following order codes 550 Calibration 580 Test certificate Hard copy product documentation Hard copy versions of the test reports declarations and inspection certificates can also be order via order code 570 Service ...

Страница 54: ...omagnetic compatibility EMC requirements NAMUR NE 21 Electromagnetic compatibility EMC of industrial process and laboratory control equipment NAMUR NE 43 Standardization of the signal level for the breakdown information of digital transmitters with analog output signal NAMUR NE 53 Software of field devices and signal processing devices with digital electronics NAMUR NE 107 Status classification as...

Страница 55: ...search field Open product page The Configure button to the right of the product image opens the Product Configurator From your Endress Hauser Sales Center www addresses endress com Product Configurator the tool for individual product configuration Up to the minute configuration data Depending on the device Direct input of measuring point specific information such as measuring range or operating la...

Страница 56: ...m the reference point R to the first measuring point R Reference point of measurement 1 First measuring point 2 Second measuring point in the middle between the first and third measuring point 3 Third measuring point Measuring point Position 1st measuring point At a distance A from the reference point A length of antenna 500 mm 19 7 in Minimum distance Amin 1000 mm 39 4 in 2nd measuring point In t...

Страница 57: ...onsidered when selecting E and F R A F E A0032643 Minimum distance between reference point R and 100 mark Minimum span Maximum value for Empty calibration A length of antenna 200 mm 8 in Minimum value 400 mm 16 in F 400 mm 16 in E 24 m 79 ft The linearity check is performed under reference operating conditions The selected values for Empty calibration and Full calibration are only used to create t...

Страница 58: ...TAG see additional spec Position of the measuring point marking To be selected in the additional specifications Tag plate Stainless Steel Self adhesive paper label Supplied label plate RFID TAG RFID TAG Tag plate Stainless Steel RFID TAG Self adhesive paper label RFID TAG Supplied label plate Definition of the measuring point designation To be defined in the additional specifications 3 lines conta...

Страница 59: ...s output to the local display an asset management system e g FieldCare DeviceCare an automation system e g PLC Advantages Device condition information is available immediately and processed in time The status signals are classified in accordance with VDI VDE 2650 and NAMUR recommendation NE 107 and contain information about the cause of the error and remedial action Detailed description See Operat...

Страница 60: ...user The verification report can be used to prove quality measures to a third party Heartbeat Verification can replace other maintenance tasks e g periodic check or extend the test intervals SIL WHG locked devices 9 The Heartbeat Verification module contains a wizard for the proof test which must be performed at appropriate intervals for the following applications SIL IEC61508 IEC61511 WHG German ...

Страница 61: ...kler system for example which dissolves the foam This wizard can be used via FieldCare DeviceCare or a DTM based process control system Build up detection wizard The Heartbeat Monitoring module contains the Build up detection wizard The wizard is used to configure automatic buildup detection which detects the buildup of deposits on the antenna on the basis of the increased area of the coupling sig...

Страница 62: ...Weather protection cover 222 8 74 A0015466 300 11 8 275 10 8 255 1 10 1 5 6 6 1 4 3 8 1 5 164 6 46 54 2 13 3 5 6 5 5 5 A0015472 23 Weather protection cover Dimensions mm in The weather protection cover can be ordered together with the device product structure feature 620 Accessory Enclosed option PB Weather Protection Cover Alternatively it can be separately ordered as an accessory order code 7116...

Страница 63: ...d Suitable for antenna 2 GA Drip off PTFE DN50 Suitable for process connection 3 GGJ thread ISO228 G1 1 2 316L RGJ thread ANSI MNPT1 1 2 316L Order number 71336522 There is no conductive connection between the mounting bracket and the transmitter housing Risk of electrostatic charge Integrate the mounting bracket in the local potential equalization system Only to be fastened at stable materials e ...

Страница 64: ...not originally ordered and a FHX50 display is to be retrofitted you must select version B Not prepared for display FHX50 under feature 050 Measuring device version when ordering the FHX50 In this case a retrofit kit for the device is supplied with the FHX50 The kit can be used to prepare the device so that the FHX50 can be used Use of the FHX50 may be restricted for transmitters with an approval A...

Страница 65: ...feature 020 option A OVP10 71128617 For 2 channel devices feature 020 option B C E or G OVP20 71128619 Hosuing lid for retrofitting In order to keep the necessary safety distances the housing lid needs to be replaced if the device is retrofitted with the overvoltage protection Depending on the housing type the order code of the suitable lid is as follows GT18 housing Lid 71185516 GT19 housing Lid ...

Страница 66: ...tery powered gateway for simple applications with SupplyCare Hosting Up to 4 field devices with 4 to 20 mA communication FXA30 FXA30B serial Modbus FXA30B or HART FXA30B can be connected With its robust design and ability to run for years on the battery it is ideal for remote monitoring in isolated locations Version with LTE USA Canada and Mexico only or 3G mobile transmission for worldwide commun...

Страница 67: ... for HART PROFIBUS and FOUNDATION Fieldbus devices Technical Information TI01134S DeviceCare is available for download at www software products endress com The download requires a registration in the Endress Hauser software portal Alternatively a DeviceCare DVD can be ordered with the device Product structure Feature 570 Service Option IV Tooling DVD DeviceCare Setup FieldCare SFE500 FDT based Pla...

Страница 68: ...T6 Ga XA01549F XA01549F XA01549F BB ATEX II 1 2G Ex ia IIC T6 Ga Gb XA01549F XA01549F XA01549F BC ATEX II 1 2G Ex ia db ia Ga IIC T6 Ga Gb XA01552F XA01552F XA01552F BG ATEX II 3G Ex ec IIC T6 Gc XA01551F XA01551F XA01551F BH ATEX II 3G Ex ic IIC T6 Gc XA01551F XA01551F XA01551F B2 ATEX II 1 2G Ex ia IIC T6 Ga Gb 1 2D Ex ia IIIC T85 C Da Db XA01555F XA01555F XA01555F B3 ATEX II 1 2G Ex ia db ia Ga...

Страница 69: ...4 J4 JPN Ex ia IIC T6 Ga Gb JPN Ex d ia IIC T6 Ga Gb XA01726F 4 XA01726F 4 XA01726F 4 KA KC Ex ia IIC T6 Ga XA01623F 4 XA01623F 4 XA01623F 4 KB KC Ex ia IIC T6 Ga Gb XA01623F 4 XA01623F 4 XA01623F 4 KC KC Ex ia db ia Ga IIC T6 Ga Gb XA01624F 4 XA01624F 4 XA01624F 4 MA INMETRO Ex ia IIC T6 Ga XA01620F XA01620F XA01620F MB INMETRO Ex ia IIC T6 Ga Gb XA01620F XA01620F XA01620F MC INMETRO Ex ia db ia ...

Страница 70: ...DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT ...

Страница 71: ...DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT ...

Страница 72: ...DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT www addresses endress com 71394723 71394723 ...

Отзывы: