Micropilot FMR60B HART
Mounting
Hauser
17
5.3.3
Integrated antenna, PEEK 20 mm (0.75 in)
Information concerning threaded connections
• When screwing in, turn by the hex bolt only.
• Tool: open-ended wrench 36 mm
• Maximum permissible torque: 50 Nm (36 lbf ft)
Information about the mounting nozzle
The maximum nozzle length
H
max
depends on the nozzle diameter
D
.
Maximum nozzle length H
max
as a function of the nozzle diameter D
D
H
max
H
øD
max
40 to 50 mm (1.6 to 2 in)
200 mm (8 in)
50 to 80 mm (2 to 3.2 in)
300 mm (12 in)
80 to 100 mm (3.2 to 4 in)
450 mm (18 in)
100 to 150 mm (4 to 6 in)
550 mm (22 in)
≥ 150 mm (6 in)
850 mm (34 in)
In the case of longer nozzles, reduced measuring performance must be expected.
Please note the following:
• The end of the nozzle must be smooth and free from burrs.
• The edge of the nozzle should be rounded.
• Mapping must be performed.
• Please contact the manufacturer's support department for applications with nozzles
that are higher than indicated in the table.
5.3.4
Integrated antenna, PEEK 40 mm (1.5 in)
Information concerning threaded connections
• When screwing in, turn by the hex bolt only.
• Tool: open-ended wrench 55 mm
• Maximum permissible torque: 50 Nm (36 lbf ft)
Information about the mounting nozzle
The maximum nozzle length
H
max
depends on the nozzle diameter
D
.
Maximum nozzle length H
max
as a function of the nozzle diameter D
ØD
H
max
H
øD
max
40 to 50 mm (1.6 to 2 in)
400 mm (16 in)
50 to 80 mm (2 to 3.2 in)
550 mm (22 in)
80 to 100 mm (3.2 to 4 in)
850 mm (34 in)
Содержание Hart Micropilot FMR60B
Страница 81: ...Micropilot FMR60B HART Index Endress Hauser 81 Write access 30 ...
Страница 82: ......
Страница 83: ......
Страница 84: ...www addresses endress com 71575911 71575911 ...