iTEMP TMT142B
Operation options
Hauser
17
6
Operation options
6.1
Overview of operation options
6.1.1
Measured value display and operating elements
Local operation
1.
2.
3.
3 mm
4.
5.
ON
OFF
Bluetooth
A0041867
Procedure for setting the DIP switch:
1. Remove the cover clamp.
2. Unscrew the housing cover together with the O-ring.
3. If necessary, remove the display with the fitting kit from the electronics module.
4. Configure the Bluetooth® function accordingly using the DIP switch. In general, the
following applies: switch to ON = function enabled, switch to OFF = function disabled.
5. Configure the hardware write protection accordingly using the DIP switch. In general,
the following applies: switch set to closed lock symbol = function enabled, switch set to
open lock symbol = function disabled.
Once the hardware setting has been made, re-assemble the housing cover in the reverse
order.
Содержание HART iTEMP TMT142B