Hauser
FHX40 - EN
2
Installation
Safety instructions:
It is very important, to connect the separate housing externally with earth. Please use
the protective earth connection at the side of the housing.
3
Commissioning
The display will function as soon as the instrument is connected with the separate
housing by the connection cable.
For using the operation, loosen all 4 screws at the cover of the separate housing and
open the cover
Note!
On delivery the Quick Setups of the instruments Prosonic M, Levelflex M,
Micropilot M and Gammapilot M are located in the FHX40. For commissioning, use
the Quick Setup valid for your instrument.
82 (3.23)
6,3 (0.25)
106 (4.17)
122 (4.8)
120 (4.72)
max. 80 (3.15)
min. 30 (1.18)
96 (3.78)
88 (3.46)
160 (6.3)
8,5 (0.33)
118 (4.65)
180 (7.09)
mm (in)
Wall-mounting
(without mounting bracket)
Pipe-mounting (mounting bracket
and plate supplied optionally,
s. product structure)
pipe