Description of parameters
Cerabar S/Deltabar S/Deltapilot S 4...20mA HART
44
Hauser
7
Description of parameters
!
Note!
• The following tables list all the parameters as per the menu structure. Each table corresponds to
a function group in the menu tree. The overall menu structure is illustrated in Section 9.1.
• The menu structure for on-site operation and the digital communication are slightly different. The
differences mainly affect the MEASURING MODE and LANGUAGE parameters and the
LINEARISATION function group.
• In the operating program or HART handheld terminal, additional parameters are displayed. These
parameters are marked accordingly.
• The menu path is indicated in the header of each table. You can use this path to get to the
parameters in question.
• The menu has a different structure depending on the measuring mode selected. This means that
some function groups are only displayed for one measuring mode, e.g. the "LINEARISATION"
function group for the "Level" measuring mode. If certain requirements have to be met for a
function group, these are listed in the first row of the table.
• Some parameters are only displayed if other parameters are appropriately configured. For
example, the EMPTY CALIB. parameter is not displayed in the Quick Setup menu ("Level"
measuring mode) unless the "Linear" option was selected for the LEVEL MODE parameter and
the "Wet" option was selected for the CALIBRATION MODE parameter. There is a comment in
the parameter description here stating: Note: prerequisite: LEVEL MODE = Linear and
CALIBRATION MODE = Wet.
• Parameter names are written in upper case in the text.
• In the "Parameter name" column, the unique identification number (ID) of the parameter is
indicated in brackets. This ID only appears on the on-site display.
P01-xxxxxxxx-19-xx-xx-xx-079
Fig. 21:
1st selection level in menu, LANGUAGE (
see Page 44, Table 1) and MEASURING MODE (
see Page 45,
Table 2)
1)
1)
1)
2)
1) Display via
o
n-sit
e d
isplay
o
nly
2) Display via
d
igital
co
mmuni
c
ati
o
n
Pressure
Level
Flow
O
PER
AT
IN
G
MENU
M
e
asu
red
valu
e
G
R
O
UP
S
ELEC
T
I
O
N
L
A
N
G
U
AG
E
ME
AS
URIN
G
M
O
DE
QUICK
S
E
T
UP
ME
AS
URIN
G
M
O
DE
Table 1: GROUP SELECTION
LANGUAGE – on-site operation
Parameter name
Description
LANGUAGE (079)
Selection
Select the menu language for the on-site display.
!
Note!
• In the operating program and in the HART handheld terminal, the LANGUAGE
parameter is arranged in the DISPLAY function group.
• Select the menu language for FieldCare via the "Options" menu
"Settings"
"Language" tab
"Tool language" field.
Factory setting:
English