Index tables of Hauser parameters
The following tables list the manufacturer-specific device parameters for the Resource Block,
the Transducer Blocks and the Analog Input Blocks. For the FF parameters, see either the
FF Specification or Operating Instructions BA00303P "Description of Device Functions,
Cerabar S/ Deltabar S/Deltapilot S". These parameters are not displayed in the block view in
FieldCare (exception: Analog Input Blocks).
General explanatory remarks
Data type
• DS: data structure, contains data types such as Unsigned8, Octet String etc.
• Bit enumerated
• Float: IEEE 754 format
• Visible String: ASCII coded
• Unsigned:
– Unsigned8: value range = 0 to 255
– Unsigned16: value range = 0 to 65535
Storage Class
• D: dynamic parameter
• N: nonvolatile parameter
• S: static parameter
If this is a write parameter, the MODE_BLK column indicates the block mode in which the
parameter can be written. Some parameters can only be written in the OOS block mode.
The "Reset codes" column indicates which reset codes reset the parameter.
Resource Block
Parameter name,
option "Symbolic name"
Parameter name,
option "Label"
Index Data type
Size
(Byte
)
Storage
Class
Read Writ
e
MODE_BLK Reset
codes
ENP_VERSION
ENP version
44
Visible String
16
S
x
DEVICE_TAG
Device tag
45
Visible String
32
S
x
x
1)
AUTO, OOS
SERIAL_NUMBER
Serial number
46
Visible String
16
S
x
x
)
AUTO, OOS
ORDER_CODE
Order code
47
Visible String
32
S
x
x
)
AUTO, OOS
FIRMWARE_VERSION
Firmware version
48
Visible String
16
S
x
SW_LOCK
Insert PIN no.
49
Unsigned16
2
S
x
x
AUTO, OOS
7864, 333
STATUS_LOCKING
Status locking
50
Unsigned16
2
D
x
HARDWARE_REVISION
Hardware rev.
74
Visible String
16
S
x
FF_COMM_VERSION
FF comm. version
75
Visible String
16
S
x
BLOCK_ERR_DESC_1
Block Error desc.
76
Bit enumerated
4
D
x
DEVICE_DIALOG
Device dialog
77
Unsigned8
1
D
x
ELECTRONIC_SERIAL_NUMBER
Electr. serial no.
78
Visible String
16
S
x
PROCESS_CONNECTION_TYPE
Proc. conn. type
79
Unsigned16
2
S
x
x
AUTO, OOS
7864, 333
MAT_PROC_CONN_POS
Mat. proc. conn. +
80
Unsigned16
2
S
x
x
AUTO, OOS
7864, 333
MAT_PROC_CONN_NEG
Mat. proc. conn. -
81
Unsigned16
2
S
x
x
AUTO, OOS
7864, 333
SEAL_TYPE
Seal type
82
Unsigned16
2
S
x
x
AUTO, OOS
7864, 333
SCI_OCTET_STRING
SCI_OCTET_STR
83
Visible String
40
S
x
x
AUTO, OOS
MS_RESOURCE_DIRECTORY
RESOURCE DIRECTORY
84
Unsigned16
20x2
S
x
1)