background image

Condumax CLS15D/16D/21D

Technical data

Hauser

29

CLS21D

Electrodes

Graphite

Sensor shaft

Polyethersulfone (PES-GF20)

Thermal conductivity socket for

temperature probe

Titanium 3.7035

Clamp process connection

• Process connection

• Seal

 

• Stainless steel 1.4435

• EPDM

9.5.3  

Process connection

CLS15D

Thread NPT ½" and ¾"

Clamp 1½" as per ISO 2852

CLS16D

Clamp 1", 1½", 2" as per ISO 2852 (also suitable for TRI-CLAMP, DIN 32676)

Tuchenhagen VARIVENT N DN 50 to 125

NEUMO BioControl D50

CLS21D

Thread G1

NPT 1" thread

Clamp 2" as per ISO 2852

Sanitary connection DN 25 and DN 40 as per DIN 11851

9.5.4  

Surface roughness (only CLS15D, CLS16D)

CLS15D

R

a

 ≤ 0.8 μm

CLS16D

R

a

 ≤ 0.8 μm, electropolished

R

a

 ≤ 0.38 μm, electropolished, optional

Содержание CLS15D

Страница 1: ...roducts Solutions Services Operating Instructions Condumax CLS15D 16D 21D Sensors with Memosens protocol For conductive measurement of conductivity in liquids 0 BA01147C 07 EN 05 20 71464661 2020 01 3...

Страница 2: ...EU Declaration of Conformity Condumax CLS15D 16D 21D 2 Endress Hauser EU Declaration of Conformity ATEX NEPSI II 1G Ex ia IIC T3 T4 T6 Ga IECEx Ex ia IIC T3 T4 T6 Ga...

Страница 3: ...Condumax CLS15D 16D 21D EU Declaration of Conformity Endress Hauser 3 ATEX NEPSI II 3G Ex ic IIC T3 T4 T6 Gc...

Страница 4: ...ntification 10 3 3 Scope of delivery 11 3 4 Certificates and approvals 11 4 Installation 13 4 1 Mounting the sensor 13 4 2 Post installation check 17 5 Electrical connection 17 5 1 Quick wiring guide...

Страница 5: ...gerous situation Failure to avoid the dangerous situation can result in a fatal or serious injury LCAUTION Causes consequences If necessary Consequences of non compliance if applicable Corrective acti...

Страница 6: ...vity of liquids They are used in the following fields Sensor Applications Hazardous areas Condumax CLS15D Measurements in pure and ultrapure water Approved for Ex zone 0 Condumax CLS16D Measurements i...

Страница 7: ...certified conductivity sensors CLS15D CLS16D CLS21D may only be connected via the measuring cable CYK10 G I to the certified intrinsically safe digital sensor output circuits of measuring device Liqui...

Страница 8: ...to the certified intrinsically safe digital sensor output circuits of measuring device Liquiline M CM42 KV The electrical connection must be made according to the wiring diagram of the transmitter Me...

Страница 9: ...and product identification 3 1 Incoming acceptance 1 Verify that the packaging is undamaged Notify the supplier of any damage to the packaging Keep the damaged packaging until the issue has been resol...

Страница 10: ...For use in hazardous areas FM CSA IS NI Cl I Div 1 2 Gr A D Name Type Version Condumax CLS15D CLS16D CLS21D V V V Process connections materials not Ex relevant For use in hazardous areas ATEX NEPSI I...

Страница 11: ...on relating to your device is displayed in this window as well as the product documentation Manufacturer s address Endress Hauser Conducta GmbH Co KG Dieselstra e 24 D 70839 Gerlingen 3 3 Scope of del...

Страница 12: ...e Stating the individual cell constant 3 4 6 Biological reactivity test USP class VI CLS16D only Biological reactivity test certificate according to USP United States Pharmacopeia part 87 and part 88...

Страница 13: ...NPT or or clamp 1 As an option the sensor can also be installed using a commercially available T piece or cross fitting or using a flow assembly NOTICE Incorrect mounting or disassembly The Memosens h...

Страница 14: ...18 25 0 98 6 0 24 38 5 1 52 1 2 3 A0019014 2 With NPT thread in flow assembly 71042405 dimensions in mm inch 1 Sensor holder NPT 2 Inlet 3 Outlet 1 Ensure that the electrodes are fully immersed in th...

Страница 15: ...ork under air evacuated conditions Otherwise the CO2 in the air can dissolve in the water and its weak dissociation can increase the conductivity by up to 3 S cm 4 1 3 CLS21D Clamp connection Both she...

Страница 16: ...stalled via a flow assembly NOTICE Incorrect mounting or disassembly The Memosens head could become loose and fall off resulting in total sensor failure Only mount the sensor via the process connectio...

Страница 17: ...ost installation check 1 Are the sensor and cable undamaged 2 Is the sensor installed in the process connection and is not suspended from the cable 5 Electrical connection LWARNING Device is live Inco...

Страница 18: ...ne 0 IIC 2G CPS11D CPS12D CPS71D CPS72D CPS91D CPS92D CPS16D CPS76D CPS96D CPS171D IIC 1G IIC 3G EX Zone 1 Zone 0 Zone 2 CYK10 Ex ia Ga CPS41D CPS42D CYK10 Ex ia Ga EX CLS50D CLS15D CLS16D CLS21D COS2...

Страница 19: ...for zone 2 CPS11D CPS12D CPS71D CPS72D CPS91D CPS92D CPS16D CPS76D CPS96D CPS171D EX CYK10 Ex ic CPS41D CPS42D CYK10 Ex ic EX CLS50D CLS15D CLS16D CLS21D COS22D COS51D CPS471D CPS491D CPS441D CLS82D C...

Страница 20: ...he degree of protection Only the mechanical and electrical connections which are described in these instructions and which are necessary for the required designated use may be carried out on the devic...

Страница 21: ...efore applying pressure to an assembly with cleaning system ensure that the system has been connected correctly If you cannot reliably establish the correct connection do not install the assembly in t...

Страница 22: ...ldup from flue gas desulfurization or wastewater treatment plants Use a mixture of hydrochloric acid 3 and thiocarbamide commercially available and then rinse thoroughly with plenty of clear water 4 B...

Страница 23: ...ice for information on replacing the seal and recalibration in the factory 8 2 Return The product must be returned if repairs or a factory calibration are required or if the wrong product was ordered...

Страница 24: ...ion to water at 25 C 77 F CLS15D A 0 04 to 20 S cm CLS15D B L 0 10 to 200 S cm CLS16D 0 04 to 500 S cm CLS21D 10 S cm to 20 mS cm Temperature CLS15D 20 to 100 C 4 to 212 F CLS16D 5 to 100 C 23 to 212...

Страница 25: ...asuring system traceable to NIST or PTB The exact cell constant is entered into the manufacturer inspection certificate supplied The uncertainty of measurement in determining the cell constant is 1 0...

Страница 26: ...operation 5 to 120 C 23 to 248 F Sterilization max 45 min Max 150 C 302 F at 6 bar 87 psi absolute CLS21D 20 to 135 C 4 to 275 F at 3 5 bar 50 psi absolute 1 Threaded versions max 30 minutes The maxi...

Страница 27: ...20 40 60 80 100 120 140 C 212 p abs T A0031428 EN 11 Mechanical pressure temperature resistance A Can be sterilized for a short time 1 hour CLS16D 6 5 20 60 100 120 150 23 60 68 120 180 240 248 300 20...

Страница 28: ...anical construction 9 5 1 Weight CLS15D and CLS21D Approx 0 3 kg 0 66 lbs depending on version CLS16D Approx 0 13 to 0 75 kg 0 29 to 1 65 lbs depending on version 9 5 2 Materials CLS15D Electrodes Pol...

Страница 29: ...eel 1 4435 EPDM 9 5 3 Process connection CLS15D Thread NPT and Clamp 1 as per ISO 2852 CLS16D Clamp 1 1 2 as per ISO 2852 also suitable for TRI CLAMP DIN 32676 Tuchenhagen VARIVENT N DN 50 to 125 NEUM...

Страница 30: ......

Страница 31: ......

Страница 32: ...www addresses endress com 71464661 71464661...

Отзывы: