![Endress+Hauser ATEX II1/2GD Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/endress-hauser/atex-ii1-2gd/atex-ii1-2gd_safety-instructions_2407689032.webp)
XA00097D
Proline Promass 80
32
Hauser
Electrical connection
Connection compartment
Transmitter housing compact/remote version (terminal assignment, connection data
32 ff.)
A0005611
Fig. 6:
Electrical connections
a
Power supply cable (terminal assignment, connection data
b
Signal cable (terminal assignment, connection data
33)
c
Ground terminal for signal cable shield
d
Ground terminal for protective ground
e
Service adapter for connecting the service interface FXA193 (Fieldcheck, FieldCare)
Terminal assignment and
connection data:
Power supply
4 to 20 mA HART
1
2
L1 (L+)
N (L–)
20
21
22
23
24
25
26
27
e
b
c
a
+
–
+
–
+
–
+
–
d
All transmitters
1 L (+)
2 N (–)
*
Designation
Supply voltage
Protective earth
Functional values
AC: U = 85 to 260 V;
AC: U = 20 to 55 V
DC: U = 16 to 62 V
Power consumption: 15 VA / 15 W
Caution!
Observe the grounding
concepts of the system!
Intrinsically safe circuit
no
U
m
260 V AC