These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
Assembly / user instructions
W28 10
Diagram A
Diagram B
Diagram C
1. Determine the position of your light fitting taking
into account the entry position of the cable and
make sure there is sufficient cable coming out of
the wall to connect to the terminal block. Ensure
that the mounting surface is solid, preferably a
brick or block wall and ensure that there are no
other cables or pipes beneath the surface.
2.
Diagram A.
Fit the 2 threaded posts in the back
plate and bring the mains cable through the
rubber grommet then use the back plate as a
template and mark the 2 fixings holes, making
sure the back plate is correctly aligned so that the
threaded bolts are horizontal. Use appropriate
fixings to secure the back plate to the wall.
3.
Diagram B
. Connect the house wiring to the
internal terminal block. The cable entry grommet
must be securely in place to ensure that the water
ingress protection is maintained.
NOTE:
This is a
Class I fitting and
must be earthed.
Connect
the incoming mains as per the diagram–
do not
put any incoming cables into position X.
4. Diagram C.
Fit the terminal block onto the post in
the back plate and then fit the front frame over the
2 threaded bolts in the back plate and secure with
the 2 threaded nuts. Take care not to trap or
strain the internal cables.
5.
Diagram D
. Construct the lid section as shown.
Fit the appropriate bulb into the lamp holder
NOTE:
Never fit a bulb of a higher wattage
than that specified on the label (as this may
cause overheating and damage the fitting).
Secure the lid onto the head frame.
6.
To Test the Lantern. Turn on the power. See
Diagram E.
To test the PIR unit in daylight, turn
the timer dial (with clock) gently fully anti-
clockwise (towards the clock) and turn the light
level dial (sun / moon) gently fully clockwise
(towards the moon). Activate the PIR by covering
the PIR lens with your hand. The unit will light and
should stay on for approximately 6-10 seconds
then go off. It will remain off until the light level
drops.
7.
To adjust Time On
. By adjusting the
timer dial
the unit will stay on (once activated) from 6
seconds (fully anti-clockwise) to 2 minutes (Fully
clockwise).
8.
To adjust light level.
By adjusting the Light level
dial the unit will activate either in daylight (fully
anticlockwise) or at night (fully clockwise).
NOTE:-
1. All time on values are approximate.
2. At initial power-on activation, the lantern will
switch on and may remain on for up to 2
minutes. Keep out of the way of the activation
zone and once the light goes off make the
setting adjustments.
Diagram D
Diagram E
Threaded bolts
Fixing screws
Grommet
Terminal post
Threaded nuts