Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without your
knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the
connections.
This system contains non-replaceable parts and cannot be
serviced. If damage occurs the part should be scrapped.
This product is not suitable for dimming.
This product is rated at IP44.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
8W LED (SMD 2835)
IP rating:
44
Layout
• Plan the desired layout of this fitting carefully, ensuring
the cables will reach the distance between the junction
box and the light fitting.
• Avoid locating any cables in positions that would cause
a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk
from being cut, trapped or damaged.
• Cables in walls must be protected using suitable
conduit or plastic trunking.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm².
• This product has special protection against the ingress
of moisture and is IP44 rated.
• This product is fitted with a no touch infra-red switch,
helping to keep it clear of fingerprints. When mounting
the mirror, the sensor switch must be at least 150mm
from an adjacent wall or obstruction to ensure the
switch can function properly.
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting,
carefully note the position of each set of wires
.
• The installation of this product will be easier with the
help of an assistant.
• Loosen fixing screws and remove the mirror panel from
the back. Keep the screws in a safe place for refitting later
(Fig. 1).
• Using the wall back as a template, mark the position of
the fixing holes. Drill the holes. Then fix the wall back in
place using the supplied screws and wall plugs (Fig. 2).
• Wire as detailed below.
Installation
OUTSIDE ZONES
ZONE
2
ZONE
1
0.6m
0.6m
2.25m
Ceiling
This product is suitable for use in Zone
2 and outside Zones of a bathroom.
See diagram. If this unit is being
fitted in a room containing a bath or
shower, a 30mA RCD must be used, in
accordance with IEE regulations.
incl