Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed

Please read these instructions carefully before 
commencing any work. 

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure other 
persons cannot  restore the electrical supply without your 
knowledge.

This light fitting should be connected to a fused circuit.

If replacing an existing fitting, make a careful note of the 
connections.

This system contains non-replaceable parts and cannot be 
serviced. If damage occurs the part should be scrapped.

This product is not suitable for dimming.

This product is rated at IP44.

This product contains a demister pad. If this pad is 
damaged in anyway then it should be replaced by a 
qualified electrician.

This fitting is heavy and you will require assistance in 
connecting them to the supply and securing them to the 
mounting surface.

Be careful during handling and maintenance to avoid 
breakage of the glass parts.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

1 x 6W White LED's

IP rating: 

44

Layout

•  Plan the desired layout of this fitting carefully, ensuring 

the cables will reach the distance between the junction 
box and the light fitting.

•  Avoid locating any cables in positions that would cause 

a hazard. Position cables and junction boxes (not 
supplied) away from areas where they may be at risk 
from being cut, trapped or damaged.

•  Cables in walls must be protected using suitable 

conduit or plastic trunking.

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm².

•  This product has special protection against the ingress 

of moisture and is IP44 rated.

Existing fittings must be completely removed before 
installation of a new product. Before removing the existing 
fitting, 

carefully note the position of each set of wires

.

•  Ensure the wall is capable of holding the weight of the 

product. Take care to avoid damaging any concealed 
wiring and pipes. The correct fixings should be used for 
brick, cavity walls or plasterboard. 

•  Remove the mirror front by removing the 4 side screw 

assemblies, retain these for re-use. Gently pull apart the 
demister pad plug / socket (A) and remove the mains in 

terminal block connection cover (B).

•  Mark out the 4 mounting positions, and determine the 

position of the cable entry, as shown (C). Drill and plug 
the mounting surface. Bring the mains cable through the 
rubber grommet in the back housing and secure the back 
housing to the mounting surface – making sure that the 
sides are vertical and the top is horizontal. 

NOTE: The 

rubber grommet must be used at the cable entry 
point to ensure that the water ingress protection of 
the fitting is maintained.

Installation

This product is suitable for use in Zones 1, 2 
and outside Zones of a bathroom. See diagram. 
If this unit is being fitted in a room containing a 
bath or shower, a 30mA RCD must be used, in 
accordance with IEE regulations.

Make sure that there is a 200mm space between 
the sensor and any other surface e.g. a sink or 
shelf.

OUTSIDE ZONES

ZONE

2

ZONE

1

0.6m

0.6m

2.25m

Ceiling

Mains-in 

Cable

(C)

(A)

(B)

Cable entry 

grommet

Fig 1.

Fig 2.

Fig 3.