These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Assembly / user instructions 

C280 004 

Diagram  A 

Diagram   B 

Diagram C 

1.    Determine the position of your 

light fitting. Make sure there is 
sufficient cable coming out of 
the wall to connect to the 
terminal block. Ensure that the 
mounting surface is solid, 
preferably a brick or block wall 
and ensure that there are no 
other cables or pipes beneath 
the surface.

 

 

2.    

Diagram A.

 If the back plate  

bracket is attached – remove 
it by undoing the single grub 
screw. Use the back plate 
bracket as a template and 
mark the 2 fixings holes, 
making sure the back plate is 
the correct way up and the 
sides of the back plate are 
vertical. Use appropriate 
fixings to secure the back 
plate to the wall. 

 

 

3. 

   

Diagram B

. Open the terminal 

block housing (A) by taking 
out the screws (B) at either 
side of the housing. Connect 
the mains wiring to the 
internal terminal block (C) – 

see wiring details

. The cable 

entry grommet (D) and any 
seals (E) must be securely in 
place to ensure that the water 
ingress protection is 
maintained. 

NOTE:

 

This is a 

Class I fitting and

 

must be 

earthed.  

 

4.   Diagram C. 

Fit the terminal 

block housing together and 
secure with the screws – 
removed in 3 above. Fit the 
front frame over the back 
plate and secure with the 
single grub screw removed in 
2 above. Take care not to trap 
or strain the internal cables. 

 

 

5. 

   

Unscrew the top cover and fit 

the recommended CFL lamp – 
not supplied.   

NOTE: Do not 

fit lamps of a higher wattage 

than those recommended as 

this may cause overheating 

and damage the fitting.              

Re-f

it the cover over the lamp. 

 

6.    Turn on the power and test. 

 

 

 
 
 
 

Back plate 
bracket 

Incoming mains 
cable 

WIRING DETAILS 

Bracket Grub 
screw 

(A) 

(A) 

(B) 

(B) 

(C) 

(C) 

(C) 

(D) 

(E) 