Problem

Possible Cause

Prevention/Cure

Burner will not light using igniter

LP gas tank valve is closed

Make sure regulator is securely attached to the LP gas tank per “Installing LP 
Gas Tank,” then turn LP gas tank valve to “OPEN”

LP gas tank is low or empty

Exchange, refill or replace LP gas tank

LP gas leak

1 .  Turn LP gas tank valve to “CLOSED”
2 .  Wait 5 minutes for gas to clear
3 .  Follow “Checking for Leaks” section

Battery needs to be changed

Replace the “AA” battery (follow assembly step for inserting battery)

Electrode and burners are wet

Wipe dry with cloth

Electrode cracked or broken - sparks at crack

Replacement part(s) may be needed - contact Customer Care at 800 .762 .1142

Wire loose or disconnected

Reconnect wire or replacement part(s) may be needed - contact Customer Care 
at 800 .762 .1142

Wire is shorting (sparking) between igniter and electrode Replacement part(s) may be needed - contact Customer Care at 800 .762 .1142
Bad igniter

Replacement part(s) may be needed - contact Customer Care at 800 .762 .1142

Burner will not light with match

No gas flow

Check if LP gas tank is empty

a .  If empty, exchange, refill or replace LP gas tank
b .  If LP gas tank is not empty, refer to “Sudden drop in gas flow or 

reduced flame height” (see below)

LP gas tank is low or empty

Exchange, refill or replace LP gas tank

LP gas leak

1 .  Turn LP gas tank valve to “CLOSED”
2 .  Wait 5 minutes for gas to clear
3 .  Follow “Checking for Leaks” section

Coupling nut and regulator not fully connected

Turn the coupling nut about one-half to three-quarters additional turn until solid 
stop . 

Tighten by hand only - do NOT use tools

Obstruction of gas flow

1 .  Clear burner/venturi tube
2 .  Check for bent or kinked hose

Disengagement of burner to valve

Re-engage burner and valve

Spider webs or insect nest in burner/venturi tube

Clean burner/venturi tube

Burner ports clogged or blocked

Clean burner ports

Sudden drop in gas flow or reduced flame height

Out of gas

Exchange, refill or replace LP gas tank

Overfilling prevention device may have been activated

1 .  Turn control knob to “  OFF”
2 .  Wait 30 seconds and light outdoor fireplace per “Lighting” section
3 .   If flames are still too low, reset the overfilling prevention device:

a .  Turn control knob(s) “  OFF”
b .  Turn LP gas tank valve to “CLOSED”
c .  Disconnect regulator
d .  Turn control knobs to   (HIGH)
e .  Wait one minute
f .  Turn control knobs to “  OFF”
g .  Reconnect regulator and leak check connections, being careful not to 

fully open valve

h .  Light outdoor fireplace per “Lighting” section

Irregular flame pattern, flame does not run the 
full length of burner

Burner ports are clogged or blocked

Clean burner ports

Flame is yellow or orange

New burner may have residual manufacturing oils

Burn outdoor fireplace for 15 minutes and reinspect

Spider webs or insect nest in burner/venturi tube

Clean burner/venturi tube

Poor alignment of valve to burner/venturi tube

Ensure burner/venturi tube is properly engaged with valve

Flame goes out

High or gusting winds

Do not use outdoor fireplace in high winds

Low on LP gas

Exchange, refill or replace LP gas tank

Excess flow valve tripped

Refer to “Sudden drop in gas flow or reduced flame height”

Flashback (fire in venturi/burner tube(s))

Burner and/or burner/venturi tube is blocked

Clean burner and/or burner/venturi tube

Flame seems to lose heat when burning in cold 
weather - temperature below 50ºF

Ice has built up on the outside of the LP gas tank 
because the vaporization process is too slow

1 .  Turn off per “Turning Off” section
2 .  Replace with a spare LP gas tank
3 .  Reconnect LP gas tank per “Installing LP Gas Tank” section
4 .  Follow “Checking for Leaks” section
5 .  Light outdoor fireplace per “Lighting” section

For assistance, please visit us at BlueRhino.com or call 1.800.762.1142.

Содержание GAD1422T

Страница 1: ...T BlueRhino com Table of Contents Important Safeguards Page 2 Expanded View and Hardware 4 Assembly Instructions 5 Installing LP Gas Tank 7 Operating Instructions 7 Cleaning and Care 8 Product Registration 8 Replacement Parts 8 Limited Warranty 8 Troubleshooting 9 The use and installation of this product must conform to local codes In absence of local codes use the latest edition of the National F...

Страница 2: ...linder beyond 80 percent full n A fire causing serious injury or damage to property may occur if the above is not followed exactly W W Your outdoor fireplace has been checked at all factory connections for leaks Recheck all connections as described in the Operating Instructions section as shipping can loosen connections W W Check for leaks even if your unit was assembled for you by someone else W ...

Страница 3: ...ence of abrasion wear cuts or leaks the hose must be replaced prior to the appliance being operated W W This outdoor fireplace should be inspected at least annually by a qualified service person Depending on amount of use more frequent cleaning may be required Do NOT operate until all parts have been repaired or replaced W W Use only the regulator and hose assembly provided Use only the replacemen...

Страница 4: ...cs 9 9 Parts List 1 Lava Rocks 58 23 659 2 Bowl Assembly 58 23 136 3 Igniter Cover 58 23 137 4 Burner 58 23 138 5 Control Knob 58 23 139 6 Regulator Hose Assembly 58 23 140 7 Hearth 58 23 652 8 Side Panel 3 58 23 662 9 Leg A 2 58 23 663 10 Leg B 58 23 664 11 Magnet 58 23 145 12 Leg C 58 23 665 13 Foot 4 58 23 352 14 Bottom Frame 58 23 653 15 LP Gas Tank Retainer Bolt 58 23 654 16 Door 58 23 655 17...

Страница 5: ...rts 3 Tighten all hardware connections by hand first Then before completing each step go back and fully tighten all hardware Be careful not to over tighten That could damage surfaces or strip threads 4 For best results complete each step in the order presented To complete assembly you will need 1 Leak detection solution instructions on how to make the solution are included in the Operating Instruc...

Страница 6: ...Door C x 1 6 Place Lava Rocks W W CAUTION Do NOT dump lava rocks out of package Carefully place glass rocks by hand so dust does not clog burner W W CAUTION Do NOT cover pilot housing Note Lava rocks should be 0 8 2 0 in 2 5 cm long Approx 5 95 lbs 2 7 kg of lava rocks are needed included ...

Страница 7: ...ase refer to diagram for proper installation Figures 1 and 2 5 If the burner venturi tube does not rest flush to the orifice as shown please contact 1 800 762 1142 for assistance Tank Gas Line Connection 1 Make 2 3 oz of leak detection solution by mixing one part liquid dishwashing soap with three parts water 2 Make sure control knobs are in the OFF position Figure 3 3 Connect LP gas tank per Inst...

Страница 8: ...or it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and no such representations are binding on Blue Rhino Blue Rhino Global Sourcing Inc Winston Salem North Carolina 27105 USA 1 800 762 1142 10 If igniter does not light burner a Wearing heat resistant gloves position a long lit match or long lit butane lighter near the...

Страница 9: ... burner to valve Re engage burner and valve Spider webs or insect nest in burner venturi tube Clean burner venturi tube Burner ports clogged or blocked Clean burner ports Sudden drop in gas flow or reduced flame height Out of gas Exchange refill or replace LP gas tank Overfilling prevention device may have been activated 1 Turn control knob to OFF 2 Wait 30 seconds and light outdoor fireplace per ...

Страница 10: ... LP Gas Outdoor Fireplace Model No GAD1422T 10 ...

Страница 11: ...Need help 1 800 762 1142 Do not return to place of purchase Replacement Parts parts BlueRhino com 1 800 762 1142 11 ...

Страница 12: ... LP Gas Outdoor Fireplace Model No GAD1422T 12 ...

Отзывы: