Endless Pools RECSPORT R200 Скачать руководство пользователя страница 14

Page 11

Operating Instructions

You can modify the programmed schedules by selecting one 

 (middle 

left) lit button and adjusting the schedule using the   or   buttons. 

Press 

 (middle left) lit button to move between parameters.

You have several possibilities for the schedule (Mon-Fri, weekend, every 

day, or single days). The schedules will be repeated every week. The 

time and duration are set in 30 minute increments. Once you have set 

the schedule, use   (top left) lit button to go back. Ensure that you 

have selected the desired Water Care option in the main Water Care 

menu.

 

MAINTENANCE  

From the Settings page you can 

access the Maintenance menu, 

which gives you access to the 

following options:
•  Maintenance reminders
•  Standby
Use the    or   buttons to make 

a selection, and 

 (middle left) lit button to select.

MAINTENANCE REMINDERS

The control panel will remind you 

of maintenance required on your 

RECSPORT

 Recreation System, 

like rinsing or cleaning the filter. 

Each task has its own duration, 

based on normal use.
The Maintenance reminders menu 

allows you to verify the time left 

before maintenance is required, as well as to reset the time once a task 

is completed. Use the   or   buttons to move through the list.
To reset a task select it by pressing the 

 (middle left) lit button, then 

confirm by pressing the lit button next to confirm when prompted. Once 

you have confirmed the task will be reset.

STANDBY 

The Standby mode allows you to 

service your System. Pumps will stop 

for 30 minutes, and automatically 

restart after this time. Press 

 

(middle left) lit button to activate 

Standby mode.
Once Standby mode has been 

activated a screen will appear to 

show that pumps are stopped. The normal page will return at the end of 

maintenance.
Press on the button next to cancel to leave Standby mode and restart the 

RECSPORT

 Recreation System.  

DATE AND TIME 

Here you can adjust the time 

format, change the year, date, and 

time. Use the   or   buttons to 

choose the setting that you want to 

adjust, and select it by pressing 

 (middle left) lit button.

Use the   or   buttons to 

change the parameters, and 

 

(middle left) lit button to move between parameters. Press 

 (top left) 

lit button to take you back to the main Settings menu.

KEYPAD SETTINGS 

In this section, you can change the 

temperature unit, language, display 

orientation, rim around the control 

panel light color, and lock the control 

panel.
Use the    or   buttons to 

choose the setting that you want to 

adjust. Select it by pressing the 

(middle left) lit button then use the    or   buttons again to change the 

setting.
When you change the display orientation, the contextual options and    

or   buttons adjust to the chosen orientation. The Audio and Setting 

buttons remain unchanged, as well as the jets and lights buttons in the 

home page.
Security settings allow you a Partial (Temperature) lock or Full (entire 

control panel) lock. Select Security screen by pressing the 

 (middle 

left) lit button then use the    or   buttons to change to Full, Partial or 

Unlock. Press 

 (top left) lit button to display an information screen 

telling you to press and hold 

 button for 5 seconds to lock.

To unlock Full, press and hold 

 button for 5 seconds.

MISCELLANEOUS

You can turn the Warm weather 

mode ON or OFF. When ON 

the filtration pump will shut OFF 

whenever the water temperature 

gets 1°C (2°F) above the set 

point. Because of the Recreation 

system's large body of water it is 

recommended to keep the Warm 

weather mode OFF.
Press the 

 (middle left) lit button, then use the    or   buttons to 

change the Warm weather mode. 
You can also hide some information on the home screen by selecting  

Hide in "Info messages" (not recommended).

ELECTRICAL CONFIGURATION

Please do not make changes in this section! 

ABOUT 

This section shows information about the control panel software number, 

and the revision numbers of the different components of your system.

SMART WINTER MODE 

The Smart Winter Mode (SWM) is used to prevent water from freezing in 

the plumbing lines. As soon as there is a risk of freezing, this protection 

automatically kicks in. The SWM protection will turn back off only after  24 

hours without a risk of freezing. During the SWM period, the Smart 

Winter Mode icon remains on; the icon blinks when the purge is active. 

The purge period indicates the amount of time between the purging of 

the plumbing lines based on the temperature behind the panels.

Содержание RECSPORT R200

Страница 1: ...RECSPORT Recreation Systems OWNER S MANUAL by Endless Pools ...

Страница 2: ...ification and without incurring any obligation DATE PURCHASED ____________________________________ DATE INSTALLED ______________________________________ DEALER _____________________________________________ ADDRESS ____________________________________________ TELEPHONE __________________________________________ MODEL SERIAL NUMBER _______________________________ COVER SERIAL NUMBER ________________...

Страница 3: ...NTROL 13 FILTER CYCLES 13 POLLING 13 ALL OFF MEMORY ON 13 WI FI IN TOUCH 2 OPTIONAL 13 WATER QUALITYAND MAINTENANCE BASIC INFORMATION 14 CHEMICAL SAFETY 14 HOW TOADD CHEMICALS TO THE WATER 14 FUNDAMENTALS OF WATER MAINTENANCE 14 THE ENDLESS POOLS WATER MAINTENANCE PROGRAM 16 VACATION WATER CARE INSTRUCTIONS 17 GLOSSARY 18 CARE AND MAINTENANCE FILTER MAINTENANCE 19 FILTER CARTRIDGE REMOVALAND CLEAN...

Страница 4: ...dangerous voltage or other risk of injury Refer all servicing to qualified service personnel Do not attach an external antennae to a RECSPORT Recreation System audio system unless installed by a licensed electrician in accordance withArticle 810 of the National Electric Code ANSI NFPA 70 WARNING To reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may result i...

Страница 5: ...em Keep any loose articles of clothing long hair or hanging jewelry away from rotating jets or other moving components Long hair should be tied up or placed under a bathing cap Safe water temperature for aquatic Recreation is approximately 85 F 29 5 C DO NOT use this RECSPORT Recreation System alone INCREASED SIDE EFFECTS OF MEDICATION The use of drugs or alcohol may cause unconsciousness with the...

Страница 6: ... System chemicals and cleaners DON T Leave the RECSPORT Recreation System exposed to the sun without water or a cover in place Exposure to direct sunlight can cause solar distress of the shell material Roll or slide the RECSPORT Recreation System on its side This will damage the siding Lift or drag the vinyl cover by using the cover lock straps always lift or carry the cover by using the handles A...

Страница 7: ... be wired directly into a grounded circuit with a ground fault circuit interrupter GFCI No other appliances should be on the same circuit 9 The RECSPORT Recreation System should be close to a source of water 10 Do not use the RECSPORT Recreation System above a finished living area due to the risk of water damage 11 The RECSPORT Recreation System is not designed for in floor installation However it...

Страница 8: ...k side of RECSPORT Recreation System Slide panel towards center and remove repeat for other panel Insert power wires into RECSPORT Recreation System from either side towards the bottom you will find a plastic cap attached to wall Once your RECSPORT Recreation System has been filled with water turn it on and test all of the circuit breakers IMPORTANT If breaker immediately trips verify that the wir...

Страница 9: ... USE WITH GFCI SUBPANEL PROVIDED INCORRECT WIRING WILL DAMAGE CIRCUIT BOARDS REFER TO THE WIRING INSTRUCTIONS INCLUDED WITH THE SUB PANEL FOR DETAILED WIRING INSTRUCTIONS Electrical Requirements DOOR PANEL REMOVE REPLACE REMOVAL 1 Locate the vertical T spacer in the center of the equipment compartment back side of RECSPORT Recreation System 2 Remove the 4 screws using a Philips screw driver holdin...

Страница 10: ...Large Hydromassage jets provide a unique pulsating massage 6 The Midsize Directional Hydromassage jets with eyeball nozzles deliver a direct more focused massage 7 The Midsize rotational Hydormassage jets provide a rotating massage 8 The Mini Hydromassage jets feature a direct more focused massage 9 Pillow 10 Swim Speaker Optional 11 Seating area Speaker Optional 12 Suction Screen 13 Water feature...

Страница 11: ...ate valve to see which hydromassage jets are affected QUICK START UP INSTRUCTIONS BEFORE YOU FILL YOUR RECSPORT RECREATION SYSTEM Make sure your RECSPORT Recreation System has been properly installed per all local codes this includes the location of the RECSPORT Recreation System the foundation of the RECSPORT Recreation System as well as the electrical installation of the RECSPORT Recreation Syst...

Страница 12: ...ets button and place all jet pumps on High Once the jet system is fully operational as indicated by strong non surging jets priming of the RECSPORT Recreation System is complete To turn off the jets press all of the jets button on the control panel to turn off the jets If you do not feel a steady stream of water from your jets refer to the instructions for priming the pump in the RECSPORT Recreati...

Страница 13: ...t button to choose your setting A green check mark will appear on the selected icon to confirm When in Economy mode the heating set point will be reduced by 20 F 11 C which means that the heating system will not come on during the set time unless the temperature falls 20 F 11 C below the set temperature The filtration schedule shown on the screen will apply to the main filtration pump hydromassage...

Страница 14: ...and middle left lit button to move between parameters Press top left lit button to take you back to the main Settings menu KEYPAD SETTINGS In this section you can change the temperature unit language display orientation rim around the control panel light color and lock the control panel Use the or buttons to choose the setting that you want to adjust Select it by pressing the middle left lit butto...

Страница 15: ... a source using Bluetooth wireless technology or AUX aux is not available at time of publication Selection will be indicated below In stream 2 PAIRING BLUETOOTH Audio Power must be on Go to the Bluetooth settings on your device and find in stream 2 and press to connect Enter pin 5555 and press pair to sync your device NOTE Only one device at a time can be synced PLAY PAUSE AUDIO Press the Play Pau...

Страница 16: ... Magenta Azure Amber Emerald Ruby color wheel with abrupt color changes slow full color wheel and fast full color wheel NOTE If left on the light will automatically turn off after 4 hours of operation FILTER CYCLES When your RECSPORT Recreation System is first powered up the default filter cycle is set to start at 12 00 pm and will run for 5 hours each day using the Beginner Water Care mode Unless...

Страница 17: ...our RECSPORT Recreation System Handle all containers with care Store in a cool dry well ventilated place Always keep chemical containers closed when not in use Replace caps on their proper containers Don t inhale fumes or allow chemicals to come in contact with your eyes nose or mouth Wash your hands immediately after use Follow the emergency advice on the product label in case of accidental conta...

Страница 18: ...er varies from location to location and user to user therefore it is important to consult with your dealer for an appropriate program a CLEAN SCREEN pre filter The CLEAN SCREEN pre flter should be used at every fill and top off to remove contaminants from the fill water especially iron copper and manganese Many water sources including well water contain high concentrations of minerals that can cau...

Страница 19: ... waste is oxidized and removed from the water It is important to follow the recommended application and maintenance programs outlined for the product s use If the RECSPORT Recreation System is being used over an extended period of time such as a whole afternoon or evening additional sanitizer will be needed Required a One Silver Ion cartridge per 500 gallons 1 893 liters b Silver Ion cartridges to...

Страница 20: ...ion System water will be safe for you to use once the FreeAvailable Chlorine residual level has dropped below 5 0 ppm IMPORTANT If you will not be using your RECSPORT Recreation System for an extended period of time in excess of 14 days and an outside maintenance service or neighbor is not available to assist with the water maintenance draining or winterizing of the RECSPORT Recreation System is r...

Страница 21: ...ith ozone Oxidizer The use of an oxidizing chemical is to prevent the buildup of contaminants maximize sanitizer efficiency minimize combined chlorine and improve water clarity See MPS and Ozone Ozone Ozone is a powerful oxidizing agent which is produced in nature and artificially by man Ozone forms no byproducts oxidizes chloramines and will not alter the water s pH pH The measure of the RECSPORT...

Страница 22: ...L AND CLEANING INSTRUCTIONS Place the RECSPORT Recreation System in the Standby mode then proceed as follows 1 Find the filter grate inside the RECSPORT Recreation System 2 Pull the filter grate from the bottom up until it unlocks from the wall IMPORTANT ONLY PULL FILTER GRATE UP SLIGHTLY 3 Pull filter grate away from wall and set aside 4 Pull skimmer tray away from wall remove and clean 5 To remo...

Страница 23: ... help to maximize the RECSPORT Recreation System s energy efficiency NOTE When warmer weather returns approx 60 70 F 15 21 C the insulating kit must be removed to prevent overheating of the jet pump WINTERIZING YOUR RECSPORT RECREATION SYSTEM An ENDLESS POOLS RECSPORT Recreation System may be used year round even in colder climates If you will not be using the RECSPORT Recreation System during the...

Страница 24: ...commends Stain Scale Defense 3 Keep all cleaners out of the reach of children and use care when applying RECSPORT RECREATION SYSTEM CABINET All RECSPORT Recreation Systems use the exclusive all climate cabinet designed for years of performance The unique design is made from a rigid polymer for durability and adds a film finish that provides a rich appearance Cleaning consists of simply spraying th...

Страница 25: ...though mass produced not all thermal overload cutoffs are exactly the same Some are more sensitive than others and will shut the pump off at lower temperatures High temperature All ENDLESS POOLS RECSPORT Recreation System models are equipped with a jet pump shroud that vents the heat generated by the pump motor to the outside of the equipment compartment and back into the RECSPORT Recreation Syste...

Страница 26: ...er Overused or old water Clean filters Shock RECSPORT Recreation System with sanitizer Add sanitizer Adjust pH and or alkalinity to recommended range Run jet pump s and clean filters Drain and refill the RECSPORT Recreation System Water Odor Excessive organics in water Improper sanitization Low pH Shock RECSPORT Recreation System with sanitizer Add sanitizer Adjust pH to recommended range Chlorine...

Страница 27: ...evel 6 inch 15 cm below bar top Pump motor runs but low or no water jet pressure Air control valve closed Water Valves are closed Dirty filter cartridge Jet blocked Clogged suction or skimmer basket Open air valve Open any closed water valves Clean filter cartridge Remove jet face eyeball and clean orifice Clean suction cover or skimmer basket After filling or refilling the RECSPORT Recreation Sys...

Страница 28: ...ht of 175 lbs 80 kg R200 12 0 x 7 5 366 cm x 226 cm 50 127 cm 100 ft 4 000 1 335 gallons 5 054 liters 1 845 lbs 837 kg 14 730 lbs 6 680 kg 190 lbs ft 928 kg m 230 volt 30 amp Single phase GFCI protected circuit R500 15 0 x 7 5 457 cm x 226 cm 50 127 cm 100 ft 4 000 1 785 gallons 6 757 liters 2 055 lbs 932 kg 18 690 lbs 8 477 kg 195 lbs ft 952 kg m 230 volt 30 amp Single phase GFCI protected circui...