background image

4i Edge 313 

Quick Start

www.endian.com

Endian Network Account

To activate your Endian Network subscription and keep your appliance 

always up-to-date with the latest features and security updates follow these 

steps:

A. You already have an Endian Network account

1. When the system asks you if you have an Endian Network account 

choose “yes” and go to the next step.

2. Now fill in the form using your data and the activation code on the 

back of this page.

B. You do not have an Endian Network account

1. When the system asks you if you have an Endian Network account 

choose “no” and go to the next step.

2. Click on the “Endian Network account” link and insert the activa-

tion code on the back of this page.

3. Fill in the registration form and create your account.
4. Close the registration window and go to the next step.
5. Now fill in the form using your data and the activation code.

Your Endian appliance is now ready!

Mapping Table for Reference

COM Port

1

5

8

6

Pin

RS232

RS485

RS422

1

-

A-

TX-

2

RXD

A+

TX+

3

TXD

-

RX+

4

-

-

RX-

5

GND

GND

GND

6

-

-

-

7

RTS

-

-

8

CTS

-

-

9

-

-

-

Digital I/O

1

5

Pin

REF

Description

1

DO_GND

Output digital signal 

(0V ground) connected 

to the emitter of the 

transistor

2

DO

Output digital signal 

connected to the 

drain of the MOSFET 

transistor

3

DO_VDC

Common of the exo-

thermal predrive pow-

er supply (between 

+12 et +24 VDC)

4

DI_GND Ground of the input 

(isolated)

5

DI

Input digital signal

DIN-Rail Mounting

The metal DIN-rail kit is fixed to the rear panel of the 4i Edge 313. 

After opening the product box, mount the 4i Edge 313 on corrosion-free 

mounting rails that meet the EN 60715 standard.

Installation

Step 1:

 Insert the upper lip of the DIN-rail into the DIN-rail mounting kit.

Step 2:

 Press the 4i Edge 313 toward the DIN-rail until it snaps into 

place.

Din-Rail

Removal

Step 1: 

Gently pushed up from the bottom of the 4i Edge 313.

Step 2: 

Slightly pull the 4i Edge 313 forward and lift up to remove  

 

from the DIN-rail.

Din-Rail

4i Edge 313  

Quick Start

Отзывы: