Battery interior damaged, broken cell or short circuit, replace battery.
(Healthy=0, Voltage<12.4V, Electric Current=0A or 0CCA)
5) Charge, Retest
Unstable battery shall be recharged and retested to avoid error. If same
test result appears after recharge and retest, the battery is regarded as
damaged, replace the battery.
(Healthy<60%, Voltage<12.40V)
Attention: If "Replace" resulted from IN-VEHICLE mode, it mig ht be the
reason that vehicle cable is not well connected with the battery. Ensure
to cut off the cable and retest the battery under OUT-OF-VEHICLE before making a
decision to replace battery.
NOTE: After testing, if need to return, press SCROLL key to directly return to the
startup interface.
●
24V system testing.
It should not be tested on 24V directly. It will cause damage the unit. For 12V x 2
batteries (in series or parallel), disconnect the connections and test them individually.
The battery in parallel must be disconnected from the negative connection, and then
tested on a single battery. If you do not cut off the negative connection, will lead to
erroneous battery test results.
●
Language
If you hold the machine has a multi-language version, go to the menu and select the
language you use appropriate language and click ENTER and confirm the launch, so
you can use the language version of the machine
12.08 V
310 A
RATING
500A
39% OF
HEALTHY
20%
CHARGE
BAD CELL
REPLACE
CHARGE
RETEST