MANUAL ACTIVATION / RESET BUTTON
The SMART START cable provides important safety protections. These include short circuit protection,
reverse charging protection and reverse polarity protection. The SMART CABLE will also automatically
■
After
Solution:
Depress the MANUAL ACTIVATION / RESET button for 5 seconds to reset the cable.
The green light will light up solid. Refer from (D) above.
■
The car battery voltage is less than 3V;
Solution:
The jump start unit will not start automatically. Override this protection by depressing the
MANUAL ACTIVATION / RESET button for 5 seconds. Refer from (D) above.
■
A short circuit or reverse polarity situation is detected;
Solution: Resolve the problem first. Then press the MANUAL ACTIVATION / RESET button for 5 seconds
■
Only use the MANUAL ACTIVATION / RESET button when a problem has been detected, and
after you have resolved the issue causing the problem.
■
Pressing the MANUAL ACTIVATION / RESET button will cause the REVERSE POLARITY
protection to be DISABLED until such time as the SMART CABLE is physically disconnected /
reconnected to the jump start unit.
■
Be very careful NOT to reverse the polarity once the RESET button has been pressed. Otherwise
you may cause damage to the cable and the jump start unit.
5
after no activity for 90 seconds;
to reset the cable. The green indicator light will light up solid. Refer from (D) above.