3.1 Install TDS-6 Time Distribution Server Extension Unit
, continued
Procedure
, continued
Step 2
Fit chain cable
.
Plug chain cable into TDS-6 CHAIN 1 inlet port.
Plug the other end of cable into a vacant TDS-2 module CHAIN output.
Step 3
Connect TDS-6 Unit to DAG Card
On front plate of TDS-6 unit, plug cable into a vacant outlet and insert other
end into DAG card.
Step 4
Inspect TDS Unit Operating Status
On the front of TDS-6 unit, check power LED is ON and status LED’s are
flashing for:
•
PPS
•
SERIAL
On the back of the unit, check PPS LED is flashing.
NOTE: If the LED’s are not flashing check the TDS-2 module is powered,
and check connections. In event of a function failure, contact Endace
support;
3.2 Connect Additional TDS-6 Time Distribution Server Extension
Units
Description
A number of TDS-6 units can be coupled together like a daisy-chain to
enable extension of time-synchronization output to more DAG cards or
PC’s.
If the two TDS-2 module chain outputs are in use, with two TDS-6 units
already being connected, additional TDS-6 units can be chained to the first
TDS-6 units.