 FRONT PANEL COMMANDS

1. Viewing and  Changing The set point

Measurement 

value

-

30.0

-

29.9

-

30.0

1000

-

24.0

If        key is pressed for 3 seconds in "Running Mode", setpoint value is displayed and it can be changed by using           navigation keys.

  

-

9.0

Measurement

value

-

24.0

By pressing         and       keys together for 3 seconds in "Running Mode", 
defrosting sensor (probe) measurement value will be displayed.

2. Viewing Defrost Measurement  Value

 3. Locking / Unlocking the Keys

Loc

unl

1000

-

24.0

Measurement

value

Locked.

Unlocked

 4.Manual Defrost Process

By pressing to       key for 2 seconds in "Running Mode", the defrost process will start or stop manually. 
The defrosting process will be disabled if the 

d3

 parameter ( 

d.dur

 ) is set to 

0

 . 

 5.Manually Switching On or Off
    

    

    

If       key is pressed for 2 seconds during the "Running Mode", the display indicator switched off, temperature measurement and controls are not performed and outputs 

are disabled. While in this status, by pressing to      key for 2 seconds again, the current operation can be resumed.

6. Changing Parameter Values

If            keys are pressed together for 2 seconds,              message appears and the user menu is entered, and the first parameter of the user 
menu is displayed. The parameter value can be displayed by pressing           key and can be changed by using           navigation keys. 
If no operation is performed for 3 seconds while a parameter value displayed or by pressing to          key, the parameter name will be re-displayed. 
If            keys are pressed together while the parameter name displayed, "Running Mode" is entered immediately.

  Program

ming Mode

7. The Hidden Menu

If        is pressed for 7 seconds,            message appears and the hidden menu is entered, and   

R2

 

parameter is displayed.
The parameter value can be displayed by pressing          key and can be changed by using            navigation 
keys.

R2

8. Transferring Parameters Between Menus

R2

By pressing to              keys together for 2 seconds, the parameter can be transferred to user menu. Up 
to 8 parameters can be transferred. 

If              keys are pressed for 2 seconds, parameter will be removed from user menu.
If no parameter is stored in the user menu, 

nP

 message will be displayed.

R0

C2

ERROR MESSAGES

 

  

P

5

C

 Pfa

No communication with thermostat sensor.
(Sensor and/or cable broken or not connected)

Thermostat probe or connection 
line short-circuited.

Temperature value is 
higher than the scale.

Temperature value is 
lower than the scale.

ALARM SITUATION

Measurement value flashes
in case of an alarm.

-

24.0

EA

External alarm is active but
the outputs are not affected.

5

A

External alarm is active and the 
relay outputs are in OFF situation.

FACTORY DEFAULTS

Power-up the device by pressing and holding down the       key for factory defaults. 

d.Pr

 message will be displayed if the operation success.

 

  

P

5

2

 Pf2

To locking or unlocking the keypad,             keys are pressed together for 2 seconds.  

Loc

 or 

unL

 message will appears for valid status. 

During 

Loc

 status, just the setpoint value will appear if the        key is pressed.

No communication with defrost sensor.
(Sensor and/or cable broken or not connected)

Defrost probe or connection 
line short-circuited.

1

2

0

 O

h

m

Master

Slave - 1

Up to 127 slave devices 
can be controlled.

Slave - 2

Slave - 127

-

+

A

B

-

+

A

B

-

+

A

B

-

+

A

B

1

2

0

 O

h

m

* MODBUS CONNECTION DIAGRAM

Termination  should  be  accomplished  by 
attaching 120 Ohm resistors to the start and at 
the end of the communication line.

*  Applies to devices with Modbus function.

Note :

The warning led      on the 

device will blink in case of 

an error condition.

      EDT3423A-

EN

-01-

201214

ENDA

TM

Make sure the keypad is not locked before performing the following operation.