EDT
1
411
P-E-01-R
3/3
C.pon
C.FoS
C.PPn
C.PPF
Delay time for the compressor after power is on.
Delay time required for the compressor to restart following a stop.
In the probe failure.compressor’s output on duration.
In the probe failure,compressor’s output off duration.
0 255 min. 1
0 255 min. 0
C.Con
Compressor’s on the continuous on mode length of stay.
0 255 min. 0
0 255 min. 1
0.0 24.0 h. 0.1
Menu of Compressor control parameters
CP
Menu of Alarm control parameters
A.LoL
A.uPL
A.dFL
A.HYS
A.set
Alarm configuration (
A.Abs
= Absolute alarm. Alarm values are
A.LoL
and
A.uPL
.
A.rEF
= Relative alarm. Alarm values are SET-
A.LoL
and SET+
A.uPL
.)
Limit for lower alarm level. When
A.set
is changed, should be readjusted.
Limit for upper alarm level. When
A.set
is changed, should be readjusted.
Alarm differential (hysteresis)
Situation of alarm after the were formed alarm message delayed to show.
-50.0
A.uPL
°C -50.0
A.LoL
110.0 °C 110.0
0 255 min. 0
0.0 15.0
°
C 2
A.AbS
A.rEF
A.AbS
A.dPo
Time delay to display alarm message after power is on.
Al
A. rE
-
A. CP
-
A. AL
-
A.rE.S.
Security parameter for refrigeration menu
Security parameter for refrigeration setpoint value (
P.yes
= Setpoint value is invisible.,
P.no
= Setpoint value is only visible.)
Security parameter for menu of compressor control
Security parameter for menu of defrost control
Security parameter for menu of alarm control
A. DE
-
Menu of Parameter security
SE
R.HYS
R.LoL
R.uPL
R.oFF
Refrigeration differential(hysteresis)
The lower limit of the setpoint.
T
he upper limit of the setpoint.
The offset value for the refrigeration.
-50.0
°C -50
R.uPL
-20.0 20.0 °C 0.0
MÝN MAX UNIT DEF.SET
Unit
Temperature unit
DrES
Display resolution (
no
= no decimal point ,
yes
= with decimal point .)
°C °F °C
Yes
No
No
R.LoL
110.0 °C 110
Menu of Refrigeration control parameters
RE
Menu of Defrost control parameters
D.dur
D.int
D.dSP
D.drE
D.Pon
D.dPo
Defrosting duration.(If
d.dur
=0, then defrost is disable.)
Interval between defrost cycles.
Display configuration during defrost (
rEAL
= Real temperature is displayed during defrost.
def
= During the defrosting on the display
def
message visible.)
Defrosting after power is on.(
yes
=Defrosting begins when power is on,
no
=Defrosting doesn’t begin when power is on.)
Delay time for defrosting after power is on.
Delay time for display real temperature after defrost is over.
0 255 1
1 120 1
REAL
def
Yes
def
No
No
0 30 min. 1
0 255 1
DE
min.
sec.
h.
min.
min.
sec.
= Menu is invisible.
NonE
P.yes
P.no
= Parameters of menu are changeable.
= Parameters of menu are only visible.
If
A.typ
=
A.rEF
, then
A.LoL
= SET-
ALoL
&
A.uPL
= SET+
A.uPL.
NOTE : Variables for lower and upper alarm level are determined according to
A.SET
parameter. If
A.
S
ET
=
A.AbS
,then
A.LoL
=
A.LoL
&
A.uPL
=
A.uPL
.
EDT1411 DEFROST
CONTROLLED REFRIGERATION THERMOSTAT OUTPUT AND PARAMETER TABLE
Defrost
LED
Compressor
LED
Power
D.int
D.dPo
(If
d.Pon
=
y
then
d.dPo
ti
mer
runs
)
D.dur
C.Pon
Compressor
OUT
C.Con
Continuous mod
e
Defrost mod
e
A.uPl
SET
A.uPl
-
A.HYS
SET+
r.HYS
A.LoL
A.LoL
+
A.HYS
A.dPo
A.dFL
Alarm
situation
AHi
enable
AHi
able
dis
Alo
enable
Alo
able
dis
0 23.5 hr. 0.3
0.1 20.0 °C 0.1