TERMS
2/3
EDP741C-E-03-R
1) Mains supply cords shall meet the requirements of IEC 60227
or IEC 60245.
2) In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant instrument
and it should
be easily accessible by the operator.
Note:
1) Adjusted potentiometer value is seen in run mode
Parameter name, value or its unit in programming mode.
3) Decrement key during run mode.
Decrement or parameter selection key during programming mode.
2) Increment key during run mode.
Increment or parameter selection key during programming mode.
4) Used for selecting menus in programming mode.
5) Used for selecting run or programming modes and for adjusting parameters.
DIGITAL POTENTIOMETER
ENDA
EDP 741
SET
4 digits 7 segment red LED display
( 2 ),( 3 ),( 4 ),( 5 ) Keypad
( 1 ) Digital display
14.2mm
Micro switch
Character height
ENDA EDP 741 is intended for installation in control panels. Make sure that the device is used only for intended purpose.
grounded on the instrument side. During an installation, all of the cables that are connected to the device must be free of energy. The device
must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All
input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be
close to the power cables or components. The installation and electrical connections must be carried on by a qualified staff and must be
according to the relevant locally applicable regulations.
The shielding must be
10
9
184-253V AC
50/60Hz 7VA
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Neutral
Line
SUPPLY :
NOTE :
Fuse should
be connected
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
Panel
cut-out
De
pth
97mm
75mm
8
4
m
m
68 mm
+0.7
6
8
m
m
+
0
.7
2
Note 1) While panel mounting, additional distance required
for connection cables should be considered.
2) Panel thickness should be maximum 10mm.
3) If there is no 90mm free space at back side of the device,
it would be difficult to remove it from the panel.
-
Push the flush-mounting
clamp in direction
1
as
shown in the figure left.
-
Then, pull out the clamp in
direction
2.
For removing mounting clamps:
Connection
cables
Rubber packing
Flush mounting
clamp
Panel
1
2
1
7
2
m
m
7
8
m
m
DIGITAL POTENTIOMETER
ENDA
EDP 741
SET
DIMENSIONS
CONNECTION DIAGRAM
ENDA
INDUSTRIAL ELECTRONICS
E
DP741C-
230VAC
P
OTENTIOMETER
230V AC +10% -20%
50/60Hz 7VA
SN: XXXXXXXXX
9
10
OUTPUT (0-
2
0
mA
)
8
+
GND
4
3
8 680407 701872
Made in Turkey
ENDA
INDUSTRIAL ELECTRONICS
E
DP741C-
2
4
VAC
P
OTENTIOMETER
2
4
V AC
±
10%
50/60Hz 7VA
SN: XXXXXXXXX
9
10
OUTPUT (0-
2
0
mA
)
8
+
GND
4
3
8 680407 701759
Made in Turkey