TERMS

 2/3

EDP741C-E-03-R

1) Mains supply cords shall meet the requirements of  IEC 60227 

or IEC 60245. 

2) In accordance with the safety regulations, the power supply 

switch shall bring the identification of the relevant instrument 
and it should 

 

be easily accessible by the operator.

Note:

1) Adjusted potentiometer value is seen in run mode
    Parameter name, value or its unit in programming mode.

3) Decrement key during run mode.
    Decrement or parameter selection key during programming mode.

2) Increment key during run mode.
    Increment or parameter selection key during programming mode.

4) Used for selecting menus in programming mode.
    
   

5) Used for selecting run or programming modes and for adjusting parameters. 

      DIGITAL POTENTIOMETER

ENDA

EDP 741

SET

     4 digits  7 segment red LED display

  ( 2 ),( 3 ),( 4 ),( 5 ) Keypad

  ( 1 ) Digital display

 14.2mm       

      Micro switch

         Character height

ENDA EDP 741 is intended for installation in control panels. Make sure that the device is used only for intended purpose. 
grounded on the instrument side. During an installation, all of the cables that are connected to the device must be free of energy. The device 
must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All 
input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be 
close to the power cables or components. The installation and electrical connections must be carried on by a qualified staff and must be 
according to the relevant locally applicable regulations.  

The shielding must be 

10

9

184-253V AC 
50/60Hz 7VA

230V AC 
Supply

Switch

Cable size: 1,5mm²

Fuse

F 100 mA 

250V AC

Neutral

Line

SUPPLY :

NOTE :

Fuse should
be connected

Holding screw
0.4-0.5Nm 

Equipment is protected throughout
by DOUBLE INSULATION.

Panel 

cut-out

De

pth

97mm

75mm

8

4

m

m

 68     mm

+0.7

 6

8

  

  

 m

m

+

0

.7

2

Note  1) While panel mounting, additional distance required 
              for connection cables should be considered.
          2) Panel thickness should be maximum 10mm.
          3) If there is no 90mm free space at back side of the device,
              it would be difficult to remove it from the panel.

 

 -  

Push the flush-mounting 

     clamp in direction 

1

 as    

     

shown in the figure left.

 

 -  

Then, pull out the clamp in  

     

direction 

2.

 

For removing mounting clamps:

Connection

 

cables

Rubber packing

Flush mounting

 

clamp

Panel

1

2

1

7

2

m

m

7

8

m

m

      DIGITAL POTENTIOMETER

ENDA

EDP 741

SET

DIMENSIONS

CONNECTION DIAGRAM

ENDA

INDUSTRIAL ELECTRONICS

E

DP741C-

230VAC 

P

OTENTIOMETER

230V AC +10% -20% 
50/60Hz 7VA

SN: XXXXXXXXX

9  

10  

 
 OUTPUT (0-

2

0

mA

8  

GND

4

3

8 680407 701872

      Made in Turkey