OUTPUT TYPES
While counter value is equal
to preset value, OUT
becomes active.
While counter value is lower
or equal to the preset value,
OUT is active.
While counter value is
greater or equal to the
preset value, OUT is active.
C o u n t
input CP1
C o u n t
input CP2
C o u n t
input CP2
C o u n t
input CP2
ýnPt.
tyPE
Cntr.
dýr.
dýrE.
CP1.U.
CP2.d.
CP1.U.
CP2.U.
UP
Ph-4
UP.dn.
Ph-1
UP.dn.
Ph-2
CP1.U.
CP2.G.
d i r c t i o n
input CP2
CP1.U.
CP2.r.
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
L
L
n
n
n
n
n
n
n
n+1
n+1
n+1
n+1
n+1
n+1
n+1
n+1
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+2
n+3
n+3
n+3
n+3
n+3
n+3
n+4
n+4
n+5
n+4
n+3
n+3
n+3
n+5
n+5
n+4
n+6
n+6
n+7
n+7
n+8
n+3
n+3
n+3
n+4
n+4
C o u n t
input CP2
C o u n t
input CP2
C o u n t
input CP2
C o u n t
input CP2
C o u n t
input CP2
Ga
t e
input CP2
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
C o u n t
input CP1
H
H
L
L
direction
input CP2
DISPLAY
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
C o u n t
input CP1
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
L
L
n
n
n-1
n-1
n-1
n-2
n-2
n-2
n-2
n-3
n-3
n-3
n-4
n-4
n-5
C o u n t
input CP2
C o u n t
input CP2
Ga
t e
input CP2
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
oPPo.
C o u n t
input CP1
H
H
L
L
DISPLAY
n
n
n
n
n
n-1
n-1
n-1
n-1
n-1
n-2
n-2
n-2
n-2
n-2
n-2
n-2
n-3
n-3
n-3
n-4
n-3
n-3
n-3
n-4
n-5
n-5
n-6
n-6
n-7
n-7
n-8
n-3
n-4
n-3
n-4
INPUT TYPES
Cntr.
dir.
Cntr.
dir.
= , ,
= , ,
=
=
dirE.
oppo.
= , , ,
Conf.
1
Reset
9,999
Preset
0
Out
Conf.
2
Reset
9,999
Preset
0
Out
Conf.
4
Reset
9,999
Preset
0
Out
Conf.
5
Reset
9,999
Preset
0
Out
Conf.
6
Reset
9,999
Preset
0
Out
Conf.
7
Reset
9,999
Preset
0
Out
Conf.
8
Conf.
9
Conf.
10
Reset
9,999
Preset
0
Out
-999
Reset
9,999
Preset
0
Out
-999
Reset
9,999
Preset
0
Out
-999
4/5
EC442-E-07-R
inPt.
typE
inPt.
typE
inPt.
typE
CP1.U.
CP2.d.
CP1.U.
CP2.U.
CP1.U.
CP2.U.
CP1.U.
CP2.G.
CP1.U.
CP2.G.
CP1.U.
CP2.r.
UP
Ph
-
4
UP
Ph
-
4
UP.dn.
Ph
-
1
UP.dn.
Ph
-
2
= , , ,
inPt.
typE
CP1.U.
CP2.d.
CP1.U.
CP2.r.
UP.dn.
Ph
-
1
UP.dn.
Ph
-
2
Adjusting to a value between 0.1 and 999.9 seconds, a pulse output is obtained.
Adjusting to
0.0, a continuous output is obtained.
out
ti.
out
ti.
UP COUNTER
DOWN COUNTER
UP / DOWN COUNTER
(Autoreset and
Display hold)
(Delayed
Autoreset
and HOLD)
(Delayed
Autoreset )
(Autoreset )
(HOLD )
For PNP sensor, counter is triggered at the rising edge of the pulses.
For NPN sensor, if you select
above diagram for
Cntr.dýr. DýrE
replaces with
Cntr.dýr OPPo.
.
ýnPt.tyPE CP1.U. CP2.r.
,
NOTE
:
For NPN sensor counter is triggered at the falling edge of the pulses.
1)
2)