Output Functions
Connection Diagram
Supply Voltage
Order Code
230V AC +%10 -%20
24V AC %10
±
ATM9321
ATM9321-SSR
ATM9321-24
ATM9321-24-SSR
Control Output
Relay
Logic Output
Relay
Logic Output
ENDA ATM9321 is intended for installation in control panels. Make sure that the device
is used only for intended purpose. The shielding must be grounded on the instrument
side. During an installation, all of the cables that are connected to the device must be
free of energy. The device must be protected against inadmissible humidity, vibrations,
severe soiling and make sure that the operation temperature is not exceeded. All input
and output lines that are not connected to the supply network must be laid out as
shielded and twisted cables. These cables should not be close to the power cables or
components. The installation and electrical connections must be carried on by a
4
5
2
3
4
5
6
7
8
ENDA
INDUSTRIAL ELECTRONICS
ATM9321 ANALOG TIMER
SN: XXXXXXXXX
1
1
2
3
4
5
6
7
8
+
-
ENDA
INDUSTRIAL ELECTRONICS
ATM9321-SSR ANALOG TIMER
SN: XXXXXXXXX
184-253V AC
50/60Hz 5VA
230V AC Supply
Switch
Cable Size: 1,5mm²
Fuse
F 100 mA 250V AC
Neutral
Line
SUPPLY:
NOTE :
Fuse should
be connected.
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
Power
When START input is triggered, timer starts running and control output is energized.
START
Control Output
Programming Diagram
RESET
T: Setting time (minute), Ta<T
START is triggered by rising edge and it is activated after 5ms.
NOTE:
MODE A
MODE B
If this message is seen, it means the device has
a calibration error. In this case, the device should
be sent to Sisel A.Þ. or to a nearest ENDA local
representative for calibration and testing. When
this message is seen, the control output is
de-energized.
ERROR MESSAGE:
Power
When START input is triggered, timer starts running. Control output is energized after setting time is over.
START
Control Output
RESET
1)
Mains supply cords shall meet the requirements of IEC 60227
or IEC 60245.
2)
In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant instrument
Note :
While key is being turned left or right,
the parameters related to that menu appear.
To confirm the parameter, press key.
SET
If timer is energized by pressing set key, programming mode is entered.
NOTE :
Control output is off after setting time is over.
5ms
5ms
Ta
T
T
5ms
T
T
9-30V DC SMPS
ATM9321-24DC
ATM9321-24DC-SSR
Relay
Logic Output
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
Exit from programming mode
Run mode
Scale selection menu
Configuration menu for output function
Flash selection menu
E-mail : [email protected]
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN
Industrieelektronik
/ D-72160 Horb a.N
Dettinger Str. 9
2. /2 ATM9321-E-09050219