ENDA ATC9311 Скачать руководство пользователя страница 2

Process temperature value is seen. 

If time proportional control was selected,                                  is seen.

If On-Off control was selected,                                   and                                    are seen.                          

When the device is energized, selected control form is seen on the display.

If the device is energized while holding            key, control form changes and the related message 

is seen on the display. 

If          key is pressed, set value is seen.

When          key is released, process temperature is seen again. 

Temperature display

ATC9311 Programming Diagram

For selecting control form.

Error Messages

For displaying Set value

If this message is seen, it means temperature sensor was not disconnected or over
temperature condition was occurred. When this message is seen, the control output 
is de-energized.   

If this message is seen, it means the device has a calibration error. In this case, the 
device should be sent to Sisel A.Þ. or to a nearest ENDA local representative for 
calibration and testing. When this message is seen, the control output is de-energized. 

SET

SET

SET

SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

 2/2

 ATC9311-E-05-R

Connection diagram

Terminal connection

Terminal connection 

Use suitable compensation cables. Do not 
use jointed  cables. Pay attention to the 

polarities of the thermocouple cables as 
shown in the figure right.

SENSOR INPUT:

Logic output is not isolated from the inner circuits 
of the device. Therefore, when using a grounding 
thermocouple, do not connect the logic output 
terminals to the ground.  

ENDA ATC9311 is intended for installation in control panels. Make sure that 
the device is used only for intended purpose.  The electrical connections must 
be carried on by a qualified staff and must be according to the relevant locally 
applicable regulations. During an installation, all of the cables that are 
connected to the device must be free of energy. The device must be protected 
against inadmissible humidity, vibrations, severe soiling and make sure that 
the operation temperature is not exceeded. All input and output lines that are 
not connected to the supply network must be laid out as shielded and twisted 
cables. These cables should not be close to the power cables or components. 
The shielding must be grounded on the instrument side.  

+

-

Fe-Const

TC

-

+

7

4

8

5

NOTE :

Fuse should 
be connected.

184-253V AC 
50/60Hz 5VA

230V AC Supply

 

switch

Cable size: 1,5mm²

Fuse 

F 100 mA 250V AC

Neutral

Line

SUPPLY :

Holding screw 0.4-0.5Nm 

Equipment is protected
throughout by DOUBLE 
INSULATION.

1) Mains supply cords shall meet  

    

the requirements of  IEC 60799  

    or IEC 60245. 
2) In accordance with the safety 

    

regulations, the power supply 

    switch shall bring the 

    

identification of the relevant 

    

instrument and it should be 

    

easily accessible by the 

    o

perator.

Note :

Order Code :

  ATC9311-

      -  

2 - Control Output

     SSR....Logic Output
     None...Relay

1 - Supply Voltage

     230VAC...230V AC
     24VAC.....24V AC 
     SM...........9-30V DC / 7-24V AC

1            2

SET

SET

SET

SET

INDUSTRIAL ELECTRONICS

ENDA 

ATC9311-230VAC 
ANALOG THERMOSTAT

SN: XXXXXXXXX

1

2

7

6

3

4

5

O

U

T

P

U

T

2

5

0

V

 A

C

 2

A

R

E

S

IS

T

IV

E

 L

O

A

D

2

3

0

V

 A

C

 +

1

0

%

 -

2

0

%

5

0

/6

0

H

z

  

 5

V

A

8

+

-

F

e

-C

o

n

s

t

T

C

1

2

7

6

3

4

5

8

+

-

L

O

G

IC

 O

U

T

1

2

V

 D

C

 2

0

m

A

2

3

0

V

 A

C

 +

1

0

%

 -

2

0

%

5

0

/6

0

H

z

  

 5

V

A

INDUSTRIAL ELECTRONICS

ENDA 

ATC9311-230VAC

-SSR

ANALOG THERMOSTAT

SN: XXXXXXXXX

+

-

F

e

-C

o

n

s

t

T

C

Отзывы: