Process temperature value is seen.
If time proportional control was selected, is seen.
If On-Off control was selected, and are seen.
When the device is energized, selected control form is seen on the display.
If the device is energized while holding key, control form changes and the related message
is seen on the display.
If key is pressed, set value is seen.
When key is released, process temperature is seen again.
Temperature display
ATC9311 Programming Diagram
For selecting control form.
Error Messages
For displaying Set value
If this message is seen, it means temperature sensor was not disconnected or over
temperature condition was occurred. When this message is seen, the control output
is de-energized.
If this message is seen, it means the device has a calibration error. In this case, the
device should be sent to Sisel A.Þ. or to a nearest ENDA local representative for
calibration and testing. When this message is seen, the control output is de-energized.
SET
SET
SET
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
2/2
ATC9311-E-05-R
Connection diagram
Terminal connection
Terminal connection
Use suitable compensation cables. Do not
use jointed cables. Pay attention to the
polarities of the thermocouple cables as
shown in the figure right.
SENSOR INPUT:
Logic output is not isolated from the inner circuits
of the device. Therefore, when using a grounding
thermocouple, do not connect the logic output
terminals to the ground.
ENDA ATC9311 is intended for installation in control panels. Make sure that
the device is used only for intended purpose. The electrical connections must
be carried on by a qualified staff and must be according to the relevant locally
applicable regulations. During an installation, all of the cables that are
connected to the device must be free of energy. The device must be protected
against inadmissible humidity, vibrations, severe soiling and make sure that
the operation temperature is not exceeded. All input and output lines that are
not connected to the supply network must be laid out as shielded and twisted
cables. These cables should not be close to the power cables or components.
The shielding must be grounded on the instrument side.
+
-
Fe-Const
TC
-
+
7
4
8
5
NOTE :
Fuse should
be connected.
184-253V AC
50/60Hz 5VA
230V AC Supply
switch
Cable size: 1,5mm²
Fuse
F 100 mA 250V AC
Neutral
Line
SUPPLY :
Holding screw 0.4-0.5Nm
Equipment is protected
throughout by DOUBLE
INSULATION.
1) Mains supply cords shall meet
the requirements of IEC 60799
or IEC 60245.
2) In accordance with the safety
regulations, the power supply
switch shall bring the
identification of the relevant
instrument and it should be
easily accessible by the
o
perator.
Note :
Order Code :
ATC9311-
-
2 - Control Output
SSR....Logic Output
None...Relay
1 - Supply Voltage
230VAC...230V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
1 2
SET
SET
SET
SET
INDUSTRIAL ELECTRONICS
ENDA
ATC9311-230VAC
ANALOG THERMOSTAT
SN: XXXXXXXXX
1
2
7
6
3
4
5
O
U
T
P
U
T
2
5
0
V
A
C
2
A
R
E
S
IS
T
IV
E
L
O
A
D
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
5
V
A
8
+
-
F
e
-C
o
n
s
t
T
C
1
2
7
6
3
4
5
8
+
-
L
O
G
IC
O
U
T
1
2
V
D
C
2
0
m
A
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
5
V
A
INDUSTRIAL ELECTRONICS
ENDA
ATC9311-230VAC
-SSR
ANALOG THERMOSTAT
SN: XXXXXXXXX
+
-
F
e
-C
o
n
s
t
T
C