ENMGS-24+4
24 Port Gigabit Web Smart Switch w/ 4 port mini GBIC
User Guide
0
Страница 1: ...ENMGS 24 4 24 Port Gigabit Web Smart Switch w 4 port mini GBIC User Guide 0...
Страница 2: ...s subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired opera...
Страница 3: ...FUNCTIONAL DESCRIPTION 10 JUMBO FRAME 10 FLOW CONTROL AND BACK PRESSURE 10 MIRROR 10 VLAN 10 TRUNK AGGREGATION 10 QUALITY OF SERVICE QOS 10 SNMP 10 MANAGEMENT GUIDE 11 ACCESS THE MANAGEMENT INTERFACE...
Страница 4: ...ENDIX COMMAND LINE INTERFACE 32 START UP AND TERMINAL CONFIGURATION 32 LOGIN LOGOUT PROCEDURES 32 COMMAND HIERARCHY 33 ENTERING COMMANDS 33 COMMAND DESCRIPTION 34 System Commands 34 Console Commands 3...
Страница 5: ...now able to transfer high bandwidth demanded files faster and get a real efficiency improvement with the user friendly Web based management interface This product also equips 4 mini GBIC slots for yo...
Страница 6: ...Egress Rate z Support full duplex flow control and half duplex back pressure z Non blocking wire speed switching performance z Provide 8K MAC address entries and 16 24 groups VLAN table z Support firm...
Страница 7: ...ng Blinking Green A valid link is established and there is data transmitting receiving 10 100M Off No valid link on this port or the port is connected at 1000 Mbps Port Operation The auto negotiation...
Страница 8: ...To be compatible with the electric service standards around the world the switch is designed to afford the power supply in the range from100 to 240VAC 50 60Hz Please make sure that your outlet standa...
Страница 9: ...e relevant components 2 Plug the switch with the female end of the provided power cord and plug the male end to the power outlet Rack mount Installation The switch may be standalone or mounted in a ra...
Страница 10: ...P cable To make a valid connection and obtain the optimal performance An appropriate cable that corresponds to different transmitting receiving speed is required To choose a suitable cable please refe...
Страница 11: ...able to monitor the traffic of the specified port VLAN With VLAN supported the network can be segmented in groups to reduce the collisions from widely broadcasting The device supports both port based...
Страница 12: ...ation software should be started as the following configuration 1 Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings...
Страница 13: ...ing your Web Browser and enter the IP address 192 168 1 1 in the Address field 2 Key in the user name and password to pass the authentication The factory default value of User Name and Password is adm...
Страница 14: ...Homepage After authentication procedure the SYSTEM Configuration page shows up as the Homepage You may click the hyperlinks on the left side of each page to get access to each management functions 13...
Страница 15: ...the Subnet Mask of the switch Gateway Setup the Gateway of the switch Management VLAN The VLAN group that is allowed to access the WEB based management interface User Name The Login name Default admi...
Страница 16: ...speed flow control and Max frame size for each port 15 Items Functions Link Shows the link status of each port The column lights green with the link speed while there is valid connection on this port...
Страница 17: ...unmark to disable Max Frame length To adjust the size of Jumbo Frame The length is 1518 bytes The Maximum value can be up to 9216 bytes 16 To save the configuration of the system click Apply to save...
Страница 18: ...add new VLAN groups 1 Fill in a VLAN id from 2 to 4094 in the VLAN Port column 2 Select the ports for each VLAN groups 3 Click the Apply button to execute To delete a VLAN group 1 Clear the members o...
Страница 19: ...o the VLAN id will be assigned automatically to this port Ex when you make port 3 of a VLAN with VLAN id 2 the PVID 2 will be assigned automatically to port 3 2 Settings in VLAN Port aggregation and M...
Страница 20: ...For example if an Egress tagged port receives an untagged frame it will be transmitted as a PVID tagged frame For the detail tagging status please refer to the following table Untagged Tagged Packet F...
Страница 21: ...s to choose Don t forget to click the Apply to save the setting There are three aggregation modes for you to setup SMAC DMAC and XOR SMAC mode selects the path of packets according to source MAC while...
Страница 22: ...oS The port based QoS allows users to configure certain ports as high or low priority To give priority level for each port 1 Select Port in the Mode column for those ports that are going to perform po...
Страница 23: ...the Mode column for those ports that are going to perform tag based QoS Click the Apply button 2 Click the Tag priority button The Tag Priority Setting page shows up 3 Select the port that you are go...
Страница 24: ...liability 0 Normal 0 Normal 0 Normal 1 Low 1 High 1 High Note The device distinguishes packets with DSCP precedence 000 routine only To configure DSCP Based QoS configuration 1 Select DSCP in the Mode...
Страница 25: ...tors to analyze and monitor the traffic of the monitored ports Mirror Configuration 1 Select those ports that are going to be monitored by marking the checkboxes in Monitor Port column 2 Click the dro...
Страница 26: ...ndwidth for each port and configure the rules for Storm Control which limits the flow of broadcast and multicast To perform storm control 1 Click on each drop list to specify a speed for each frame ty...
Страница 27: ...ble in the drop list 2 Specify a trap IP A trap IP is the destination port for sending trap information which is usually the IP address of network administrators 3 Fill in a name in the Community Get...
Страница 28: ...devices respectively for auto and manual modes Auto Search 1 Click the Apply button to start 2 The devices being found are listed below 3 Click the IP address hyperlink to get access to the device Ma...
Страница 29: ...an all statistics or click the Refresh button to renew the statistics Detailed Statistics The Detailed Statistics is provided for users to see the detailed transmitting and receiving status of each po...
Страница 30: ...ry default value click the Yes button Note The IP address of the device will also be configured as factory default setting which is 192 168 1 1 Smart Boot This Smart Boot page allows users to select t...
Страница 31: ...te the firmware file 3 Click the Upload button to execute Note This new firmware is going to be applied on the other flash that you select in Smart Boot that is the new firmware is going to be applied...
Страница 32: ...STP RJ 45 100BASE TX Category 5 UTP STP RJ 45 1000BASE T Category 5 5e or enhanced UTP STP Fiber depend on Mini GBIC types Network Data Rate 10 100 1000Mbps Auto negotiation Transmission Mode 10 100M...
Страница 33: ...tion 6 Data rate 115200 baud 7 Data format 8 data bits 1 stop bit and no parity 8 Flow control none 9 Click the property icon select settings make sure that 10 The Function arrow and ctrl keys act as...
Страница 34: ...help to get help The help depends on the context At top level a list of command groups will be shown At group level a list of the command syntaxes will be shown If given after a command the syntax and...
Страница 35: ...evel System Configuration all System Restore Default keepIP System UserName name System Password password System Systemname name System Reboot System Configuration all Syntax System Configuration all...
Страница 36: ...System Reboot Description Reboot the switch Console Commands Commands at Console level Console Configuration Console Timeout timeout Console Prompt prompt string Console Configuration Description Show...
Страница 37: ...e for the port portlist Port list Default All ports Port Mode portlist mode Description Set or show the speed and duplex mode for the port portlist Port list Default All ports mode Port speed and dupl...
Страница 38: ...ytes including FCS for frames received on the port Tagged frames are allowed to be 4 bytes longer than the maximum frame size Use the reset option to return to default setting portlist Port list defau...
Страница 39: ...LAN egress mode port VLAN ID and accepted frame type for the port and the permanently stored VLAN table portlist Port list default All ports VLAN Add vidlist portlist Description Add VLAN entry and in...
Страница 40: ...portlist vid none Description Set or show the port VLAN ID Untagged frames received on the port will be classified to this VLAN ID Frames classified to this VLAN ID will be sent untagged on the port p...
Страница 41: ...lete portlist Description Delete link aggregation group portlist Port list Aggregations including any of the ports will be deleted Aggr Lookup portlist Description Lookup and display link aggregation...
Страница 42: ...diffserv Enable tag port or IP differentiated services class of service for the port default Show mode QoS Port portlist class Description Set or show the port class In tag mode the default class is...
Страница 43: ...disable Mirror Configuration Description Show the mirror destination port and mirror mode for source ports Mirror Port port Description Set or show the mirror destination port port Mirror destination...
Страница 44: ...class ipgateway Default IP gateway default 0 0 0 0 vid VLAN ID 1 4094 default 1 IP Web management Description Activate or deactivate the Web management enable disable Enable disable Web management de...
Страница 45: ...rate portlist Port list default All ports enable disable Enable or disable rate Set leaky bucket rate in Kbit s 128 256 512 1024 2048 3072K default Show rate Ratelimit Configuration Description Show...
Страница 46: ...or set leaky bucket rate in Kbit s 128 256 512 1024 2048 3072k default Show egress rate Ratelimit Ingress portlist enable disable rate Description Set or show the ingress configuration portlist Port l...