background image

System Wiring: 

Wire Description: 

 

Black:    Connect this wire to a stable chassis ground. (-) 

 

Red: 

Connect this wire to 12 V + Ignition.  This wire should be ON while the vehicle is in operation. 

 

Green:  Connect this wire to the Positive Left turn indicator wire. (+) when left turn indicator is activated. 

 

Yellow: Connect this wire to the positive Right turn indicator wire.  (+) when Right turn indicator is activated. 

 

White:  Connect this wire to the positive reverse light wire connection. (+) when in reverse. 

Mounting the LED Indicators: 

The LED Indicators should be mounted within the vehicle and as close to the side mirrors as possible.  They have pre-
installed backings that can be affixed to any smooth surface.  The kit also contains two metal mounting points that can 
be used to mount the indicator between panels or molding should you chose to do so.  Please insure that the wires for 
the sensor are hidden and out of the customer’s sight.  A hole can be drilled for the wires in certain custom installations. 
If a hole is used, please be sure the connector will fit through the hole and is kept intact. 

Testing and operation: 

When the installation has been completed, the unit should be tested before delivery to the customer.  Please do this in 
an open area with the ignition in the ON position. 

The unit should light the LED indicator when someone or something is within range of the rear sensors.  When on the 
right side the right indicator should light up and the same with the left.  The unit will not trigger if there is anything in 
the range of either of the front sensors.  They are used to sense stationary object such as wall on a street or freeway and 
will stop the rear sensors from triggering next to stationary object or moving objects that can be easily seen by the 
driver. 

Содержание BSD–4

Страница 1: ...ront sensors are only used by the controller to help eliminate false detection When testing on a bench it is recommended that the unit is switched to enhanced mode to verify the units operation This will turn OFF the front sensors making it easier to test Once testing has been completed please switch the unit back to Normal mode for operation If left in enhanced mode the unit will give false signa...

Страница 2: ...e saw provided to drill the correct hole size for the sensors Once drilled please remove all excess material and make sure that the hole is cleared of any burs or debris Install the sensors with the UP indicator facing UP and run the wires through the holes Carefully plan where the sensors will be mounted before drilling Insure that there is room to reach the sensor wires Drill the sensor holes wi...

Страница 3: ...troller is Factory preset with standard options but has several adjustments that can be made if needed for specific applications These are set by 4 dip switches at the right of the controller harness at the controller itself Function ON Default Normal operation OFF Unit is OFF Response NORMAL Default Front Sensors limit false alarms Enhanced NOT RECOMMENDED No Limiting Logic and will trigger often...

Страница 4: ...ween panels or molding should you chose to do so Please insure that the wires for the sensor are hidden and out of the customer s sight A hole can be drilled for the wires in certain custom installations If a hole is used please be sure the connector will fit through the hole and is kept intact Testing and operation When the installation has been completed the unit should be tested before delivery...

Страница 5: ...ndicator is applied in that direction Can the sensors be painted Yes however a light coat is recommended for best sensing results The unit is too sensitive By default the system is set at normal sensitivity giving maximum detection range This can be set to a lower setting The unit gives false readings Please insure that the response switch is set to the normal setting This product is covered by a ...