background image

BANDIT III Hardware Description

Page 11

Go to 

Table of 

Contents

Go to 

Top 

Doc

Go to 

List of 

All Docs

1.1.9.4

Wireless Ports 

The BANDIT III has one internal wireless port, and you can put a second wireless card into 
the BANDIT III’s expansion slot. (Although that second card will be in the external 
expansion slot, its wireless port is internal.)

The BANDIT III can use CDMA, EVDO, GSM HSPA, GSM GPRS, or GSM EDGE wireless 
cards, in any combination of two cards. For more information, se

Wireless Cards for BANDIT 

Products

1.1.10

Expansion Ports 

For information on the expansion ports available in the BANDIT III, see 

Ports in the BANDIT 

Products

. If the expansion port is for a wireless connection, also see 

Wireless Cards for BANDIT 

Products

1.2

Status LEDs

Light-emitting diodes (LEDs) on the front of the BANDIT III indicate the status of 
connections. The following sections describe the LEDs. See the following: 

General Status LEDs

Protocol Status LEDs

Table 1-5. Serial Port Protocols

Protocol

Features Supported

Frame Relay

• Link Management

- LMI, CCITT, Q.933 Annex A;

- ANSI T1.617 Annex D

• IP  over  Frame  Relay

• CIR Enforcement

• Fragmentation FRF12

• Fast Connection

• Prioritization

• Unicasting

• Multicasting

PPP, Multilink PPP

• Sync PPP

• Async PPP

• PAP

• CHAP

• IP over PPP

IP

 

• All standard IP features 

X.25

 

• All standard X.25 features 

Top Doc

Doc List

Module TOC

Содержание BANDIT III

Страница 1: ...ally hardened chassis with a metal cover Hardened construction allows the BANDIT III to operate over wide temperature ranges at remote sites that do not use environmental control The BANDIT III like a...

Страница 2: ...T III Chassis with Ethernet Switch Module Expanded BANDIT III Chassis with Internal Data Unit BANDIT III E M Signaling Chassis 1 1 1 Standard BANDIT III Chassis The basic BANDIT III chassis Figure 1 2...

Страница 3: ...24 48 volts DC input power Figure 1 5 or for 12 24 volts DC input power Figure 1 6 When you order a BANDIT III you specify the type of input power it will use Note Each DC powered BANDIT III chassis a...

Страница 4: ...nd 110 220 VAC Input Power Figure 1 6 BANDIT III Chassis Rear Panel Basic Model 12 24 VDC Input Power or Failover 12 24 VDC and 110 220 VAC Input Power The following items are on the back of the basic...

Страница 5: ...or X 21 56k CSU DSU port T1 E1 CSU DSU port Dual port T1 E1 CSU DSU port with drop and insert capability A second wireless card this can be the same type CDMA EVDO CDMA GPRS GSM or EDGE GSM as the in...

Страница 6: ...a Unit As stated earlier the BANDIT III is also available in an expanded model with an Internal Data Unit IDU comprising four DB25 serial ports for additional VPN functionality The expanded BANDIT III...

Страница 7: ...igurations for the BANDIT III chassis Two failover input power configurations 24 48 VDC with 110 220 VAC or 12 24 VDC with 110 220 VAC Each BANDIT III chassis that uses DC input power basic Figure 1 4...

Страница 8: ...III is available in models that accept power from a DC power source at 24 48 VDC or 12 24 VDC or in models that accept power from an industry standard autosensing 100 240 VAC adapter connected to an A...

Страница 9: ...connections to network devices Section 1 1 9 1 Ethernet Ports Section 1 1 9 2 Modem Port Section 1 1 9 3 Serial Port Section 1 1 9 4 Wireless Ports Also see Section 1 1 10 Expansion Ports Note The BA...

Страница 10: ...tp SNMP MIB II ARP Proxy ARP Routing over VPN tunnels 1 1 9 2 Modem Port An internal modem resides in the BANDIT III Connect the modem port to an RJ11 telephone jack 1 1 9 3 Serial Port The BANDIT III...

Страница 11: ...ion ports available in the BANDIT III see Ports in the BANDIT Products If the expansion port is for a wireless connection also see Wireless Cards for BANDIT Products 1 2 Status LEDs Light emitting dio...

Страница 12: ...4 indicates that the connection is up between that serial port and its connected device Table 1 6 describes the BANDIT III s LEDs Table 1 6 BANDIT III General Status LED Definitions Sheet 1 of 3 LED...

Страница 13: ...in a set is equivalent to the same number of bars displaying signal strength on a mobile phone Flashes display in one of the following patterns A set of short flashes followed by a longer final flash...

Страница 14: ...ow fifth from left Green Connection has been made to carrier Off Connection to carrier has failed Link for IDU Port 45 Top row sixth from left Green Connection has been made to carrier Off Connection...

Страница 15: ...G Good frames are passing through Byte Sync Encapsulation Good frames are passing through X 25 Level II connection exists Telnet Terminal Data transfer in either direction 1 When using spoofed protoco...

Страница 16: ...Page 16 BANDIT III Reference Module Document 1 Go to Table of Contents Go to Top Doc Go to List of All Docs Top Doc Doc List Module TOC...

Отзывы: