background image

18

 

 

 
 

 

WARRANTY

 

 

The  warranty  against  defects  in  material  and  workmanship  and  the  warranty  of  proper 

functioning  of  the  product  are  given  in  the  document  “Enecom  Warranty”  provided 

together with this manual.

 

 
 

 

CONTACTS

 

 

Headquarters

 

Via Odorico da Pordenone, 28 - 50127 FIRENZE Tel. 
+39 055 333017

 

Fax +39 055 3217162

 

 

Prato Operational Unit

 

Via Siena, 16 - 59013 MONTEMURLO (PO)  
Tel. +39 0574 653085 
Fax +39 0574 658000 

 

Turin Operational Unit

 

Via Emilia, 6 - 10099 SAN MAURO TORINESE (TO) Tel. 
+39 011 2979165

 

Tel. +39 011 2976623

 

Fax +39 011 2742438

 

 

Sales department:  

[email protected]

  

 

 

 

 

    

Содержание Enecom HF135-6-16

Страница 1: ......

Страница 2: ...MANUAL ISSUED BY Headquarters ENECOM s r l Via Odorico da Pordenone 28 FLORENCE Italy Version Title Version Date MODULES HF Instruction Manual 2 10 2017 ...

Страница 3: ...oltaic module 3 Front surface 3 Back surface 4 Identification 5 Technical specifications 6 Instructions for use 8 Installation 9 General rules for installation 9 Orientation 9 Mounting 10 Electrical connections 11 Maintenance 15 Warranty 16 Contacts 16 ...

Страница 4: ...ule 560 mm 280 mm closed HFs40 5 16 Flexible m Si module 1120 mm 282 mm HF65 6 16 Flexible m Si module 728 mm 660 mm HFs65 6 16 Flexible m Si module 1370 mm 344 mm HF80 5 16 Flexible m Si module 1104 mm 536 mm HF90 5 18 Flexible m Si module 1230 mm 536 mm HF135 6 16 Flexible m Si module 1350 mm 660 mm HFpy120 6 16 Flexible p Si module 1350 mm 660 mm HFsp 90 5 16 Flexible m Si module 970mm 536 mm H...

Страница 5: ...henomenon known as the photovoltaic effect takes place The greater is the number of silicon cells in the photovoltaic module the more electrical energy is produced The front surface of the photovoltaic module The front surface of the module must be exposed to direct sunlight Connectors Cables Junction box Cells The junction box at the request of the customer can be placed on the back surface ...

Страница 6: ...ack surface In HF and HFs modules the back surface of the module has no components it provides only the identification label bearing the serial number of the module and the electrical data plate unless the junction box has been positioned on the back surface in which case the junction box will also be present Serial number and module data ...

Страница 7: ...ower 5 Open circuit voltage 6 Short circuit voltage 7 Voltage at maximum power 8 Current at maximum power 9 Maximum system voltage 10 Nominal power measured at Standard Test Conditions STC Do not remove or tamper with the label MODULE TYPE 1 Serial Number 2 Data produzione 3 gg mm aa Maximum power Pmax 4 Wp Open circuit voltage Vca 5 V Short circuit current Isc 6 A Voltage at max power Vmp 7 V Cur...

Страница 8: ... mm Weight kg 0 5 0 8 1 3 1 5 1 3 2 2 Cell efficiency 18 6 18 6 Output terminals MC4 connectors Maximum system voltage 600 V Technical specifications of the HFs HFsp HFpy line HFs40 5 16 HFs65 5 16 HFsp90 5 16 HFsp120 5 21 HFpy120 6 16 Maximum power Pmax Wp 40 65 90 120 120 Open circuit voltage Voc V 19 63 20 2 19 9 25 66 19 68 Short circuit current Isc A 2 80 4 36 6 01 6 01 8 56 Voltage at Pmax V...

Страница 9: ...Cell efficiency 18 6 Output terminals Cigarette lighter style socket MC4 connectors Maximum system voltage 600V Technical specifications of the wired junction box Junction Box Size 82 x 64 x 13 mm Diode one two bypass diodes IF 12 A VDC 45V Temperature range 40 80 C Protection class IP67 Technical characteristics of the connectors HF20 5 16 HFp20 5 16 HFp40 5 16 HF40 5 16 HFs40 5 16 HFs65 6 16 HF8...

Страница 10: ...cause serious injury or death Use caution The photovoltaic module must be handled with care without excessive bending The minimum suggested curvature radius is 1meter if lesser curvature radius is needed contact the technical support that will provide you a response about the feasibility of the installation Do not move the panel taking it by the connection cables Do not put localized pressure on t...

Страница 11: ... avoid any contact between the metallic material and the electrical terminals of the module During installation be careful to comply with safety regulations and general instructions Installation should only be undertaken in dry conditions keeping the photovoltaic module and all tools dry and adequatelyinsulated Do not install the photovoltaic module in the vicinity of flammable gases or vapors Cho...

Страница 12: ... fixing system and for a correct installation this space has to be at least x 1 mm from the top of the eyelet and the fixing system x 2 mm from the internal diameter of the eyelet and the screw See below an example of a mechanical fixing system using a washer or a spacer and a screw During mounting avoid applying pressure on the cells or overbidding the panel Eyebrow fixing is also suitable for su...

Страница 13: ...no air bubbles between the adhesive and the surfaces do not subject the cells of the module to localized pressure during mounting this can cause serious damage to the solar cells Fastening with double sided adhesive makes it difficult to remove the module from the surface on which it is glued without damaging it due to the high adhesion strength that is created between the surfaces It is therefore...

Страница 14: ...nection the positive connector of one module must be connected to the negative connector of the one next to it in this way a voltage corresponding to the sum of the electrical voltages of each individual module will be present between the free connector of the first module and the free connector of the last module VOLTAGE CURRENT ThisoptionisnotapplicabletomodulesHF20 5 16 HFp20 5 16 HFp40 5 16 wi...

Страница 15: ...ion requires the use of additional connectors parallel connectors which can be ordered separately from our accessory range VOLTAGE CURRENT Warning This type of connection is indicated when all modules are exposed to the sun in the same way We suggest that the installation of more than two modules should be performed by a qualified technician Warning All the modules connected in parallel must be id...

Страница 16: ...technical office Any erroneous connections to the solar charger will cause the void of the guarantee and may be a source of malfunction of the system See below some example of connection to an accumulator Charge regulator Accumulator Charge regulator Extension cables Accumulator Direct connection is possible only with usage devices that have a built in battery and charge regulator Modules HF20 5 1...

Страница 17: ... in areas with high smog levels or the presence of birds or trees The intensity of the effect depends on the opacity of the accumulations grime soot leaves bird droppings etc In many cases rain may reduce or eliminate the accumulation of impurities on the modules Cleaning involves simply washing the module with fresh water or isopropyl alcohol using non abrasive sponges Do not use pressurized wate...

Страница 18: ...gether with this manual CONTACTS Headquarters Via Odorico da Pordenone 28 50127 FIRENZE Tel 39 055 333017 Fax 39 055 3217162 Prato Operational Unit Via Siena 16 59013 MONTEMURLO PO Tel 39 0574 653085 Fax 39 0574 658000 Turin Operational Unit Via Emilia 6 10099 SAN MAURO TORINESE TO Tel 39 011 2979165 Tel 39 011 2976623 Fax 39 011 2742438 Sales department info enecompower com ...

Страница 19: ...CONTATTI ...

Страница 20: ...dquarters v O da Pordenone 28 30 32 50127 Firenze Italy www enecom hf com info enecom hf com Prato Operational Unit Via Siena 16 59013 Montemurlo PO Turin Operational Unit Via Emilia 6 10099 San Mauro Torinese TO ...

Отзывы: