Installation

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.

 

Plug the ULT-PLG into the operator according to instructions provided by the manufacturer.

 

2.

 

Configure  the  DIP  switches  according  to  preferences.  Refer  to  Settings  &  Display  for  
more information. 

 

3.

 

If  using  multiple  loops  or  suspect  crosstalk/interference  from  the  environment,  perform  a 
frequency count on each detector to confirm that the operation frequencies are different. 

 

 

Press  the  FREQUENCY  COUNT  /  RESET  button  and  count  the  number  of  flashes  of  the  
red  LED.  Each  flash  represents  10kHZ.  Counts  from  3  to  13  confirm  that  the  detector  
is tuned to a loop.  

 

 

If  multiple  loops  and  detectors  are  utilizing  the  same  or  very  similar  frequency,  
configure  DIP  switches  7  and 8  on one of the  devices. For example: Move  one ULT-PLG  
to the low frequency setting and the second ULT-PLG to the high frequency setting. 

4.

 

Press  the  FREQUENCY  COUNT  /  RESET  button  to  re-initialize  the  detector  and  program  the  
DIP switch settings.

 

5.

 

Adjust the sensitivity setting to desired level to assure detection of all vehicle traffic.  

 

 

To test the sensitivity, without moving the sensing loop, drive a  vehicle near the loop. 

When the vehicle is first detected by the loop, “9” will be displayed on the ULTRAMETER™

 

display. Position the vehicle over the loop where the detection point is desired, take note 
of  the  number  displayed  on  the  ULTRAMETER

  and  change  the  sensitivity  setting  

(10-position rotary switch) to match that number.  

 

 

Move  the  test  vehicle  away  from  the  loop  to  remove  it  from  the  detection  zone 
(ULTRAMETER

 display should be blank).  

 

 

Press the FREQUENCY COUNT / RESET button on the ULT-PLG.

  

 

 

Retest the product by moving the vehicle into and out of the detection zone to make sure 
the set-up and location are working as intended.

 

6.

 

Press the FREQUENCY COUNT BUTTON / RESET button to calibrate the ULT-PLG to the loop. 