Troubleshooting
Symptom
Possible cause
Solution
Units stays in detect
Unit out of alignment
Reflector covered with dirt,
dust, snow, or water
Water inside of reflector
Verify alignment
Clean reflector surface of
contaminants
Replace reflector
Add Reflector 0-HD
No Output
No power
Bad Connection, wires broken
Mis-wired
Check wiring as per chart on page 2
Check connections
Verify wired to correct inputs on
operator
No Detection
Unit not powered
Other reflective surface
causing signal return
Check Power
Check surrounding area for reflective
surface
Installation
Recommended alignment technique is to mount the NIR-50 at the desired location and hold reflector
about 2 or 3 feet in front of the unit and while watching the lights to assure that both remain lit, move
backward to the desired mounting location for the reflector. You may have to move the reflector up,
down, left or right to keep the reflector in the middle of the signal path. This assures the least
troublesome set up by keeping the reflector off the edges of the signal where any movement may take
it out of alignment. Note: the signal pattern is only 2 feet diameter.