background image

 

 

 

 

4564 Johnston Parkway, Cleveland, Ohio 44128 

P. 

800 426 9912 

F. 

216 518 9884 

Sales Inquiries: 

[email protected] 

Technical Support: 

[email protected] 

www.emxinc.com 

WEL-200 

W I R E L E S S   E D G E   L I N K

 

 

TM 

O

P

E

R

A

T

IN

G

 I

N

S

T

R

U

C

T

IO

N

S

 

 

Operating Instructions

 

Содержание WEL-200 Series

Страница 1: ...44128 P 800 426 9912 F 216 518 9884 Sales Inquiries salessupport emxinc com Technical Support technical emxinc com www emxinc com WEL 200 W I R E L E S S E D G E L I N K TM O P E R A T I N G I N S T R...

Страница 2: ...ons 1 Document no 10320104 Revision 2 0 3 1 18 Cautions and Warnings Contents2 Specifications 3 Product Overview 4 Controls and Indicators 5 Connections 7 Installation and Operation 8 Troubleshooting...

Страница 3: ...ollowing two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation UL File E3157...

Страница 4: ...y Form C contacts NO COM NC OPEN direction 300Hz pulsed Open collector transistor output opto isolated CLOSE direction 300Hz pulsed Open collector transistor output opto isolated NA Resistive terminat...

Страница 5: ...suring compliance with 2018 UL325 monitoring standards Each transmitter can run for up to two years on two AA lithium batteries The receiver connects with up to four transmitters with separate relay a...

Страница 6: ...n assignment switch Assigns channel to either open or close direction output function 6 Power indicator On constantly when receiver is powered up 7 Status indicator Shows current system status 8 Close...

Страница 7: ...or the best performance and longest life Observe polarity indication on the battery holder 2 Transmitter status LED Blinks twice every two seconds if not connected once if connected Blinks once every...

Страница 8: ...rection 4 PLS CLOSE OUT Pulsed output for CLOSE direction 300 0 Hz 5 RELAY OPEN NC Normally closed connection for OPEN direction 6 RELAY OPEN COM Common connection for OPEN direction 7 RELAY OPEN NO N...

Страница 9: ...hannel to either OPEN or CLOSE direction relay function depending on the location of each edge 4 For 10K resistive monitoring place the jumper in the 10K position for both OPEN and CLOSE direction rel...

Страница 10: ...cables sizes 0 069 0 187 1 8 4 7mm To maintain a watertight seal use only round cables do not use individual wires or any cable that is not round 1 Remove sealing nut 2 Remove dark insert from body co...

Страница 11: ...atus LED will flash on off once every 2 seconds 2 2 Set channel to the desired OPEN CLOSE direction function using the MODE dip switch 2 3 Install 2 AA Lithium batteries in the WEL 200T transmitter 2...

Страница 12: ...behavior double check the edge wiring termination and transmitter batteries Notes 1 If channel 1 and 4 switches are pressed simultaneously during power up the receiver will perform a factory reset an...

Страница 13: ...to 12k check wires for damage Relay NO COM connected pulse output 0 Hz LED flashes 2x per cycle 0 25 seconds on 0 25 seconds off Edge resistance above normal improper connection damaged wires Make sur...

Страница 14: ...r cable damage the offending channel s LED will turn on for 0 25 seconds 2x per cycle If the transmitter batteries fall below their ideal operating voltage the LED for its assigned channel will turn o...

Страница 15: ...WEL 200 Operating Instructions 14 Document no 10320104 Revision 2 0 3 1 18 Transmitter is inactive ON OFF 0s 0 25s 0 5s 0 75s 1s 1 25s 1 5s 1 75s 2s Dimensional Outline Receiver...

Страница 16: ...WEL 200 Operating Instructions 15 Document no 10320104 Revision 2 0 3 1 18 Dimensional Outline Transmitter...

Страница 17: ...misuse overloading altered products damage caused by incorrect connections lightning damage or use other than intended design There is no warranty of merchantability There are no warranties expressed...

Страница 18: ...WEL 200 Operating Instructions 17 Document no 10320104 Revision 2 0 3 1 18 BLANK PAGE...

Страница 19: ...WEL 200 Operating Instructions 18 Document no 10320104 Revision 2 0 3 1 18 BLANK PAGE...

Страница 20: ...ocument no 10320104 Revision 2 0 3 1 18 4564 Johnston Parkway Cleveland Ohio 44128 United States of America www emxinc com Technical Support 216 834 0761 technical emxinc com Sales 216 518 9888 Fax 21...

Отзывы: