Selecting the relay output mode
Remove the top cover by depressing the tabs in the bottom cover at the mounting tabs.
Hold down the function switch (see location in picture bottom right of page 3) for 3 seconds, the
LED will blink indicating the current output mode.
To change the function, press the function switch. Each press of the function moves the program to
the next function. (see diagram on bottom right page 3). To change from 4 second default to 1
second output you would press and hold the function switch until the LED blinks, then press the
function switch 4 more times.
After you have changed the output function count the blinks of the LED to verify the desired
function has been selected.
To exit the programming press the function switch for 3 seconds or wait for it to time out in 15
seconds.
To use the LR-650-Dipole you must remove the top cover as
explained above.
Plug the polarized lead from the antenna into the Red connector
shown in picture below, location (Dipole Connector).
You must then cut LP3 shown in picture below, location (JP 3).
Note:
antenna range will vary greatly depending on the operating
environment. Do not mount on metal poles or surfaces as these
will reduce or prevent the signal from being detected. Mount the
antenna as high as possible for best reception and range.
Programming Relay Functions
(continued)
Installing the Optional LR-650-Dipole