Both the transmitter and receiver lenses may be aligned
left, right or straight ahead. To align gently pull the lens
stem straight out from mounting position and snap back
into place pointing in the desired direction.
Units should be placed a minimum of 12
– 16 inches
from the floor. Across from and lenses facing each
other. The receiver red detect LED will be on when the
beam is broken or not aligned.
Note:
Rain, dust, fog, excess light or other adverse
conditions may reduce the maximum range.
Place the BPE-50 away from heat and electromagnetic
sources for best operation. Mount units a minimum of
12 inches 30 cm from the floor.
Apply power to the units and set jumpers per instruction
on see figures 1 and 2.
Test installation to insure desired and proper operation.
All local and operator manufacturer installation
instructions should be followed.
The BPE-50 transmitter may be hooked up to an edge
sensor for alternative activation operation.
The BPE-50 does not require any special care, but it is
necessary to check condition occasionally to insure they
are operating correctly. (Batteries are still operational if
on battery power)
Recommended battery replacement is the
Varta ERAA 3V6
2400
.
4564 Johnston Parkway
Cleveland, Ohio 44128
United States of America
WEB
http://www.emxinc.com
Technical Support
Telephone (216) 834-0761
Sales
Telephone (216) 518-9888
Fax (216) 518-9884
Email [email protected]
BPE-50 Instructions
rev 1.2
06/20/2013
Jumper Configuration
(Fig 2)
Lens Alignment
(Fig 3)
Installation
(Fig 4)
Jumper
ON
OFF
Receiver J1 (Gain)
Normal
High
Transmitter J2
(frequency)
Fast
Slow
Transmitter J3 (Security
edge)
Not
connected
Connected
Jumper Settings for figure 2
When transmitter frequency is set to low battery
life will be increased. The range will be reduced
at this setting. However when the transmitter is
powered by 12/24 VDC or 24 VAC the range will
be maximum regardless of the jumper setting.