Emulex OneConnect OCm10102-N-XI Скачать руководство пользователя страница 9

OneConnect VFAs for IBM BladeCenter Release Notes

Page 6

 

9. Excessive time and packet loss during failover has been observed on Windows 2003 systems.
10. Low throughput of network stress testing with vNIC enabled has been observed.
11. The 10Gb/s iSCSI VFA continually logs in and out of the array when trying to create a HWI 

iSCSI session.

12. Even when vNIC is disabled, the universal converged network adapter (UCNA) requires a 

'Virtual' port defined for use with Open Fabric Manager. When creating an initial configuration 
with the Advanced Management Module's Open Fabric Manager utility, ensure 'Virtual NIC' is 
checked in Advanced Options. With an Open Fabric Manager configuration file created in this 
way, the UCNA uses the MAC addresses assigned to ports 5 and 7 as the type 'Virtual'. With 
vNIC disabled, the MAC addresses assigned to vPorts 1 and 2 are used. With vNIC enabled, the 
MAC addresses assigned to vPorts 1 through 8 are used.

13. The inner VLAN tag values are not cleared when vNIC mode is disabled. If a VLAN tag value 

was assigned to any vNIC interfaces while vNIC was enabled, this may prevent traffic from 
passing through the interface. To prevent this issue, ensure VLAN tags are removed from all 
vNIC interfaces before disabling vNIC mode. This can be accomplished with the NIC 
configuration utility within UEFI setup.

14. For OCm10102-series UCNAs, FIP Response packets must be VLAN tagged when the UCNA is 

configured in vNIC mode. This can be easily achieved by enabling tagpvid on the corresponding 
INT port. For simplicity, a similar configuration is recommended for OCm11102-series UCNAs.

Technical Tips

1. Windows uninstaller does not remove drivers and services.

After using the Windows 'Uninstall or change a program' feature to remove all the kit compo-
nents, the drivers remain on the system. A VFA adapter is configured with teams using the latest 
elxocm-window’s driver kit. Without first removing the teams, the following software is unin-
stalled from 

Control Panel > Uninstall a Program 

(uninstalled in the order listed):

Emulex elxocm

Emulex OCManager

Emulex Common SAN Management

Uninstalling these utilities does not result in the removal of the related drivers and services. This 
is working as designed.

2. Firmware version reported differently with FCoE personality enabled.

When the VFA has the FCoE personality enabled, the firmware version is displayed as 
2.7

xx.xxx.xxx

 in the UEFI setup utility and in the operating system (as reported by ethtool). By 

design, FCoE firmware (2.7

xx

) is differentiated from NIC firmware (2.1

xx

) by the 7 and 1. If the 

FCoE storage protocol is enabled and the VFA is being booted via PXE, the NIC version of the 
firmware will be displayed in the PXE Select banner. This may be perceived as a cosmetic error, 
but is actually working as designed. 

3. Using the offline ISO firmware flash utility

The Emulex VFA (CFFh) for IBM BladeCenter required a specific update during a previous 
release to properly update the FPGA and configuration regions on the adapter. This update pro-
cedure must be followed before updating to the latest firmware or issues are likely to occur. If an 

Содержание OneConnect OCm10102-N-XI

Страница 1: ...m11102 N X OCm11102 I X OCm11102 N XI and OCm10102 N XI Virtual Fabric Adapters CFFh for IBM BladeCenter Release Notes for OneConnect SW Version 5 2 36 One Network One Company P007447 01A Rev A Connec...

Страница 2: ...InSpeed LightPulse MultiPulse OneCommand OneConnect One Network One Company SBOD SLI and VEngine are trademarks of Emulex All other brand or product names referenced herein are trademarks or register...

Страница 3: ...oduction 1 Product Overview 1 New Features 2 Supported Switches 2 Supported Network Switches 2 Supported Storage Switches 2 Supported Operating Systems and Versions 3 Updating the Firmware 3 vNIC Inte...

Страница 4: ...OCm11102 N X and OCm11102 N XI VFAs only Dual port 10 Gb adapter supporting multiple virtual I O functions Virtual NIC Physical ports can be divided into a maximum of eight virtual NICs per adapter w...

Страница 5: ...Virtual Fabric vNIC Switches BNT Virtual Fabric 10G Switch Module Physical NIC Switches IBM BNT Virtual Fabric 10G Switch Module QLogic 10Gb Ethernet Passthru Module 10Gb Ethernet Pass Thru Module for...

Страница 6: ...SP3 SUSE Linux Enterprise Server 10 SP4 SUSE Linux Enterprise Server 11 SUSE Linux Enterprise Server 11 SP1 VMware ESX ESXi 4 0 VMware ESX ESXi 4 0 Update 3 VMware ESX ESXi 4 1 Update 2 VMware vSpher...

Страница 7: ...code When you install RHEL6 1 to iSCSI boot code even if you attempt to use the out of box iSCSIi driver DUP ISO the inbox driver version is loaded first which in turn prevents the out of box ver sio...

Страница 8: ...he latest IBM supported driver version identified on the IBM pages of the Emulex website Advanced Mode is a new feature introduced in the 4 0 1062 0 firmware release For more infor mation about Advanc...

Страница 9: ...sily achieved by enabling tagpvid on the corresponding INT port For simplicity a similar configuration is recommended for OCm11102 series UCNAs Technical Tips 1 Windows uninstaller does not remove dri...

Страница 10: ...rmware NVSRAM download causes I O fail in SLES11 and RHEL5 If you are connecting to an IBM DS3XXX iSCSI storage array and you encounter delayed write failures or issues during controller firmware down...

Отзывы: