EMSYST EMS 600 Скачать руководство пользователя страница 1

 

EMSYST, spol. s r.o., Súvoz 111, SK -  911 01 Trenčín 

tel/fax 00421/32/7432400, e-mail: [email protected] 

 
 
 
 
 
 
 
 

EMS 600 

 

Service instructions 

 

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 

Trenčín, June 2017 

 

 

Содержание EMS 600

Страница 1: ...1 EMSYST spol s r o Súvoz 111 SK 911 01 Trenčín tel fax 00421 32 7432400 e mail mail emsyst sk EMS 600 Service instructions Trenčín June 2017 ...

Страница 2: ...d cells and torque sensors Signal from the sensor is amplified converted to a number calculated and then presented on a display It is also possible to read the value via USB interface to a PC Fig 1 EMS600 Fig 2 EMS600 Connectors and Power switch Connectors and power switch Display Keyboard Batteries USB Sensor OFF ON ...

Страница 3: ...ection Connection to computer Connect the device to computer with standard USB cable There is USB Mini B connector on the device The connector layout is on the figure 4 Pin Názov Popis 1 VCC 5 VDC 2 D Data 3 D Data x NC No connect 4 GND 0 V Fig 4 USB interface 3 Operating Connect a sensor and switch on the device After switching on the number of the last connected sensor appears on the display e g...

Страница 4: ...ess the key After pressing change the value of item with or To save the set up value press again for leaving without saving press The values are saved even after power is turned off Menu description there are default values in brackets rnG 9999 Range of the display The range can be set from 9999 to 9999 after overload max value the device displays oooo Min value can t be set it is automatically ne...

Страница 5: ...lue for 3 seconds 2 Pressing holds the display for 6 seconds 3 Pressing holds the display permanent Subsequent pressing abort the hold function after the lapse of 6 seconds Note The min a max values are not saved in a FLASH memory after switching off they are lost It is possible to clear the both values manually too During display max or min value press the key until the display turn off The new v...

Страница 6: ...cation driver will be installed on the computer automatically Then operating system assigns a free COM port to the device e g COM5 Via this virtual COM port device communicates For communication use the software EMS Center on the producer s home page EMS Center software is used for communication with the device It is available for free on producer s home page ...

Страница 7: ... batteries 7 Technical parameter Power supply 2 x alkaline battery 1 5V size AA Battery current approx 20 mA Operating time min 40 hours Power supply of sensor 3 VDC Resistance of sensor min 300 Ω Sensitivity of sensor 1 2 5 mV V Display accuracy 4 digit 9999 9999 Communication USB 2 0 Working temperature 0 60 C Covering IP40 Housing material ABS Dimensions 154 x 88 x 28 mm Weight 230 g 8 Manufact...