SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
23-15-30
1-5
8 MAY 09
Table 1-1 lists the physical characteristics and equipment specifications for the HSD-Xi
terminal.
Table 1-1 HSD-Xi Characteristics and Specifications
Characteristic
Specification
Physical Characteristics
Size
2 MCU ARINC 600-10 Form Factor
Weight
8.8 lbs maximum
Cooling Air
Unit capable of continuous duty cycle operation, with
or without forced air-cooling provided, as per ARINC
600 specifications. Refer to 1110-E-0401.
Electrical Characteristics
Power dissipation
34 W
Input Power
115 V ac, 400Hz, 75 va
Input frequency range
1530.0 to 1559.9 MHz
Output frequency range
1626.5 to 1660.5 MHz
Receiver input impedance
50 ohms
Transceiver output
impedance
50 ohms
Input level operational
-107 dBm to -47 dBm
Input level no damage
+10 dBm
External Interfaces
Crosstalk bus
ARINC 429 high-speed (100 kbps) data bus
Maintenance port RS-232
data loader front and rear
connector
RS-232 serial bus supports 57.6 kbps data load
capacity
ISDN user interface
64 kbps ISDN Euro input and output
Ethernet
10BASE-T (full and half duplex)
Table 1-2 lists the environmental specifications for the HSD-Xi terminal.
Table 1-2 HSD-Xi Terminal Environmental Characteristics
Characteristic
Specification/Category
Temperature and Altitude
A4 without cooling air, C4 with
cooling air
Low Operating Temperature
-40 ºC (A4), -40 ºC (C4)
High Operating Temperature
+ 55 ºC (A4), +70 ºC (C4)
Altitude
Maximum operating altitude:
15,000 ft (A4), 55,000ft (A5)
Содержание eNfusion 1252-A-4100-01