5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 

 

 

FCC Part 22 

 Transmitter Certification 

 

Test Report 

 

FCC ID:  DNY0A1EKOMINI8 

 

FCC Rule Part: CFR 47 Part 22 Subpart H 

 

ACS Report Number:  05-0373-22H 

  

Manufacturer: EMS Wireless 

Equipment Type:   Cellular Bi-Directional Amplifier 

Model: EKOMINI-8

 

 
 
 

 

Operator’s Manual 

Содержание EkoMini 8

Страница 1: ...x 770 831 8598 FCC Part 22 Transmitter Certification Test Report FCC ID DNY0A1EKOMINI8 FCC Rule Part CFR 47 Part 22 Subpart H ACS Report Number 05 0373 22H Manufacturer EMS Wireless Equipment Type Cellular Bi Directional Amplifier Model EKOMINI 8 Operator s Manual ...

Страница 2: ...EkoMiniTM BAND SELECTIVE INDOOR REPEATER OPERATOR S MANUAL 2850 Colonnades Court Norcross GA 30071 U S A Tel 770 582 0555 Fax 770 729 0075 ...

Страница 3: ... are cautioned however that EMS Wireless reserves the right to make changes without notice and shall not be responsible for any damages including consequential caused by reliance on the material presented including but not limited to typographical arithmetical or listing errors Copyright Information EMS Wireless EMS Wireless Norcross Georgia ...

Страница 4: ...operation Failure to comply with the following general safety precautions and with specific precautions described elsewhere in this manual violates the safety standards of the design manufacture and intended use of this product EMS Wireless assumes no liability for the customer s failure to comply with these precautions WARNING WARNING Calls attention to a procedure or practice which if ignored ma...

Страница 5: ...s to verify the quality and reliability of our products EMS Wireless uses every reasonable precaution to ensure that every device meets published electrical optical and mechanical specifications prior to shipment Customers are asked to advise their incoming inspection assembly and test personnel as to the precautions required in handling and testing ESD sensitive opto electronic components Physica...

Страница 6: ...turn authorization shall be received from the EMS Wireless Customer Support prior to returning any device Advise EMS Wireless Customer Support of the model serial number and the discrepancy The device shall then be forwarded to EMS Wireless transportation prepaid Devices returned freight collect or without authorization may not be accepted b Prior to repair EMS Wireless Customer Support will advis...

Страница 7: ...IS AGREEMENT INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EMS WIRELESS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING BUT NOT LIMITED TO INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS PARTS AND SERVICE HEREUNDER OR THE PERFORMANCE USE OF OR INABILITY TO USE THE GOODS PARTS AND SER...

Страница 8: ...ownlink signal must be presented to the EkoMini Without the downlink signal the unit will not operate properly The EkoMini is capable of automatically adjusting its own signal gain levels up to the maximum output power levels The EkoMini detects the downlink output power and adjusts the level for 20 dBm composite output power and continues to monitor and reset the gain as required for proper syste...

Страница 9: ...ths are adjusted to the same setting by the microprocessor unless the user offsets reduces the gain in the uplink signal path The user has control to reduce the uplink gain by 6 dB this can be used to balance the uplink and downlink paths as well as reduce contribution of noise to the base station receivers See Figure 1 below Figure 1 Switch Settings Orientation of the switches for on off The dip ...

Страница 10: ...usts the gain to prevent overdriving the linear power amplifier circuits The EkoMini monitors the downlink detected signal and adjusts the gain to achieve rated output power 20 dBm The uplink attenuation is adjusted by the microprocessor to the same gain level Path loss is normally equal in both directions The microprocessor continues to monitor the detected output power on both paths to prevent o...

Страница 11: ...ating band A B or C with the model one and D E or F with model 2 is user selectable with two dip switches as follows Band Selection Band Width Switch 3 Switch 4 A 15 on on B 15 on off C 15 off on Band Selection Band Width Switch 3 Switch 4 D 5 on on E 5 on off F 5 off on If the switches are improperly set Off Off the unit will not function This fault will be indicated by the DC power on LED Indica...

Страница 12: ...ff off The units are factory set for filter centering at the middle of the bands therefore channels at the beginning and end of the bands will be filtered out For example in the B band channels 334 to 337 will be filtered out Likewise in the A band channels 330 to 333 will be filtered out If a customer needs to utilize channels near the band edges that might otherwise be filtered out EMS can custo...

Страница 13: ...delay Pin 10 digits Alarm Code 20 numeric digits 2 Telephone Number 20 digits maximum Include required access codes such as 9 if required by a PBX A comma is used to insert a delay Pin 10 digits Alarm Code 20 numeric digits Delay 3 numeric digits 0 to 999 minutes 3 Telephone Number 20 digits maximum Include required access codes such as 9 if required by a PBX A comma is used to insert a delay Pin ...

Страница 14: ...nds or longer will reset the auto shut down Failure Action Alarm Code Alarm Cleared 0 Synthesizer Lock Uplink Auto Shut Down 1 Synthesizer Lock Downlink Auto Shut Down 2 Downlink RF Overdrive Auto Shut Down 3 Uplink RF Overdrive Auto Shut Down 4 No Downlink RF Detected Alarm Only 5 Internal Voltage Failure Alarm Only 6 Low Current Draw Alarm Only 7 Keep Alive 1 Auto Shut Down 8 External Alarm Alar...

Страница 15: ...icator State Description On Off No DC Input Power Applied Green DC Power on normal function Green Flashing DC Power on Set up fault Band Selection Alarm Off No Alarm Red Flashing 5 Minute Warning See list of alarms Red Alarm Uplink RF Power levels per picture below Downlink RF Power levels per picture below No RF Uplink Detected this is a normal state for the uplink RF path The normal levels of RF...

Страница 16: ...ach unit has a unique electronic serial number This number is displayed on the decal on the unit and is also displayed with the history log when using the modem interconnect Installation Note 1 Only qualified technicians should perform Installation and system set up The user is cautioned that modification or changes to this device not expressly approved by the party responsible for compliance coul...

Страница 17: ...p procedure assumes sufficient isolation between antennas is assured When the donor antenna is mounted outside and the rerad server antenna is mounted inside of a building isolation is assured to be adequate Since the EkoMini has a minimum gain of 40 dB isolation of at least 55 dB must be obtained between the donor and the rerad antenna Should adequate isolation not be obtained an oscillation coul...

Страница 18: ... Set DL RF Output Power to desired maximum Level Factory Preset to full Power 20 dBm Composite Set Protocol selection Switch Factory Preset to All Other SW 5 OFF For set up of optional remote alarming refer to software set up instructions Setting Up Remote Alarming Alarm Code String Sent The EkoMini will Page the Report Dial Out number and send the following format Site location 00 Alarm code Exam...

Страница 19: ...eters BAUD 2400 Word 8 Stop 1 Parity None Flow None Terminal Emulation Auto Detect Note The EkoMini has a factory Default Auto Answer Set for 2 Rings After The Unit answers the prompt Welcome to the Remote System will appear B Press the ENTER key The Prompt Password Will appear C Enter a valid password and press enter Note If this is the first time the unit is contacted it should be done with a su...

Страница 20: ... 01 31 29 for 1 31 am or 13 31 29 for 1 31 pm L Set Date DT format 01 10 99 for Jan 10 99 Note Report 1 Dial is the number that the EkoMini will dial should an ALARM condition occur If desired the Report 2 Dial and Report 3 Dial can be set to different Telephone Numbers The Report 2 and Report 3 have by default a cumulative delay set to 5 minutes each So that After 5 minutes of an alarm state Repo...

Страница 21: ...ommunication with the remote computer the unit WILL SHUTDOWN and report alarm condition if possible The unit will then need to have it s power cycled or reactivated by the remote computer if the unit can be contacted should the deactivation be related to power failure telephone line out etc at the remote computer location Setting up Keep Alive STEP 1 Connect to Unit STEP 2 SET KACTV YES STEP 3 Con...

Страница 22: ...RING Keep Alive Rings to Answer 0 99 KCODE Keep Alive Transmission String xxxx must be Numeric if Message tone KDIAL Keep Alive Dial Out Number xxxx up to 20 digits KRTRY Keep Alive Dial Retries Before Alarm 0 99 RP DIAL Report 1 2 3 Dial out Number 20 digits RP PINN Report 1 2 3 Pin Number 10 digits RP DLAY Report 2 3 Dial Delay minutes from Previous Report 0 999 RP ACTV Report Active Yes or No R...

Страница 23: ... default auto answer set for 2 rings Factory Default Settings KTIME 03 30 24 hr format KACTV No KTYPE Answer KMESS None KRING 5 KCODE Serial Number KDIAL 000 KRTRY 3 RP DIAL 000 RP PINN 000 RP DLAY 5 RP ACTV No RP TYPE Number serial PW 1 11111 PW 2 10000 PW 3 10001 UN Serial Number AR 2 ...

Страница 24: ...EMS Wireless EMS Wireless EkoMini Manual 23 ...

Страница 25: ... Source No Uplink RF Indication Check RF Antenna Input Recycle AC Power No Change Reset Switch No Change Replace Unit Remote Alarms inoperable Generate Alarm Remove RF input Program Software Software OK Check Telephone line Telephone Line OK Replace Unit No RF DownLink Power Check Band Switches Set Switches Recycle Power Switches Set Properly Replace Unit Low DownLink RF Power Check Input Power Le...

Страница 26: ...Bm 6 to 20 dBm Return Loss 15 dB 15dB Impedance 50 Ohms 50 Ohms Noise Figure Maximum 8 dB 8 dB Gain Maximum 70 dB nominal 70 dB nominal Gain Range 30 dB 30 dB Gain Steps 2 dB 2 dB Peak Limiting adjustable 14 dB 14 dB Reverse Path Gain Offset below forward Path gain setting 0 to 6 dB 2 dB Steps 0 to 6 dB 2 dB Steps Spurious 13 dBm 13 dBm Signal Delay 4 usec 4 usec Input RF Signal Max Level 20 dBm 2...

Страница 27: ...5 2 5 10 11 14 18 or 25 MHz Number of Channels Multiple Multiple Output Power Composite Adjustable 6 to 20 dBm 6 to 20 dBm Return Loss 1 5 1 1 5 1 Impedance 50 Ohms 50 Ohms Noise Figure Maximum 8 dB 8 dB Gain Maximum 70 dB nominal 70 dB nominal Gain Range 30 dB 30 dB Gain Steps 2 dB 2 dB Reverse Path Gain Offset below forward Path gain setting 0 to 6 dB 2 dB Steps 0 to 6 dB 2 dB Steps Spurious 13 ...

Страница 28: ...EMS Wireless EMS Wireless EkoMini Manual 27 2850 Colonnades Court Norcross GA 30071 U S A Tel 770 582 0555 Fax 770 729 0075 900 0801 A17 Rev 3 ...