Empire RH-25-5 Скачать руководство пользователя страница 1

Page 1

R-2065

 

VENTED

ROOM HEATER

MODELS

RH-25-5
RH-35-5

EFFECTIVE  DATE

JUNE, 2000

INSTALLATION  INSTRUCTIONS

AND

OWNER’S  MANUAL

WARNING:  If the information in
this manual is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
loss of life.

 — Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

 — WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;
do not use any phone in your build-
ing.

Immediately call your gas supplier
from a neighbor’s phone.  Follow
the gas supplier’s instructions.

If you cannot reach your gas sup-
plier, call the fire department.

 — Installation and service must be per-

formed by a qualified installer, service
agency or the gas supplier.

WARNING: If not installed, operated
and maintained in accordance with the
manufacturer’s instructions, this prod-
uct could expose you to substances in
fuel or from fuel combustion which can
cause death or serious illness.

Содержание RH-25-5

Страница 1: ...ATTO DO IFYOU SMELLGAS Do not try to light any appliance Donottouchanyelectricalswitch donotuseanyphoneinyourbuild ing Immediatelycallyourgassupplier from a neighbor s phone Follow the gas supplier s...

Страница 2: ...CSA 2 32b M98 by the American Gas Association and Canadian Gas Association as a Vented Room Heater and must be installed according to these instructions Any alteration of the original design installed...

Страница 3: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption...

Страница 4: ...ht storm windows and doors infiltration is normally adequate to provide for combustion and draft hood dilution Where appliances are installed in a confined space within a building the building being o...

Страница 5: ...Depressing the red button completely causes a spark to occur at the pilot To light the pilot it is important that the electrode be 1 8 3mm from the thermocouple The spark must occur at the point the b...

Страница 6: ...ontal blue and will extend past the thermocouple 1 4 6mm The flame will surround the thermocouple just below the tip On Propane LP gas slightyellowmightoccurwherethepilotflameand the burner flame meet...

Страница 7: ...er water 1 Set thermostat to lowest setting 2 Turn off all electric power to appliance if applicable if service is to be performed LIGHTING INSTRUCTIONS 6 Remove casing front from the heater and obser...

Страница 8: ...e to lack of oil 11 On Propane Gas if a whistling noise resonation occurs a Close the air shutter on the main burner in order to reduce the amount of primary air INDEX PART NO NUMBER DESCRIPTION INDEX...

Страница 9: ...the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Furnace Model Number Part Description Furnace Serial Number...

Страница 10: ...5 For RH 25 1 2 4 5 and RH 35 1 2 4 5 replace casing front 5 For DV 25 1 2 SG and DV 35 1 2 SG replace heat shield and casing front Attention Wiring harness on blower is factory assembled and installe...

Страница 11: ...WARNING Unplugging of blower accessory will not stop the heater from cycling To shut heater off Turn temperature dial or thermostat to lowest setting Turn knob on gas con trol to OFF depressing sligh...