Empire Filter Chamber Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

Page 1 of 9 

 

 

Filter Chamber 

Operating and Maintenance Instructions 

 

www.empirepumps.com 

Product & Chemical Disclaimer 

 
The user must take responsibility in the selection of the products materials of construction. Empire 
Pumps Ltd will act in an advisory role and offer recommendations; however, the user is liable for the 
product selection in line with solutions and temperatures in which the equipment is operated.   
 

Safety Precautions

 

 
WARNING: Prior to operating the filtration system read and understand the operating and maintenance 
instructions.  

WARNING: Ensure the filtration system is compatible with the fluids and temperatures being 
transferred. Always consult Empire Pumps Ltd if there is any change in chemical concentrations or 
solution temperatures.  

WARNING: Wear protective eye and personal equipment at all times when operating the pump. Follow 
standard safety procedures when handling corrosive or harmful solutions. 

WARNING: Ensure all operators of this equipment have been trained for safe working practices, 
understand its limitations and wear safety goggles and equipment at all times.  

WARNING: Correct procedures must be followed to drain the pump of all chemistries prior to physical 
inspection of the pump.  

WARNING: Excessive Pressure. Can result in serious injury or equipment damage. Do not service or 
clean the pump whilst the system is pressurised. Relieve pressure from the system prior to 
disassembly.  

WARNING: Never operate the filtration system above the specified maximum operating pressure of the 
pump.  

WARNING: Suction and discharge connections must be compatible with the solutions being pumped 
and the maximum pressure capability of the filtration system.  

WARNING: Maximum temperatures are based on mechanical stress only. Certain chemicals will 
significantly reduce the maximum operating temperature of the pump materials. Consult with the 
chemical manufacturer and Empire Pumps Ltd for solution compatibility and temperature limitations.   

WARNING: The filtration system must not be used as structural support to the piping system. Ensure 
suction and discharge pipe-work are independently supported to avoid stress on the pump parts.  

WARNING: Use only Empire Pumps Ltd genuine spare parts to assure compatible pressure rating and 
longest service life.  

Содержание Filter Chamber

Страница 1: ...mitations and wear safety goggles and equipment at all times WARNING Correct procedures must be followed to drain the pump of all chemistries prior to physical inspection of the pump WARNING Excessive...

Страница 2: ...ble pressure relief device is installed in the system to prevent over pressurisation 5 Never use the housing for fluids other than those it is rated for and ensure that the housing seal materials are...

Страница 3: ...al with the aid of PTFE tape or use an appropriate sealant as required Drains Fit the blanking caps supplied or drain valves as appropriate to the drain connections Seal with the aid of PTFE tape or u...

Страница 4: ...s evenly Remove the Vee clamp lid and closure seal Store them in a safe place where they cannot get dirty or damaged Remove the basket compression plate s as appropriate For Housings with Bolted Closu...

Страница 5: ...onto the flare at the top of the housing Replace the lid The clamp has two adjusters the normal open coupler that is to be placed at the front of the housing and a second retained adjuster at the rea...

Страница 6: ...o permit any trapped air to be expelled will maintain the operating efficiency of the filter For safety reasons it is important to ensure that venting is ONLY performed via a valve that the valve is o...

Страница 7: ...being careful to lift the O rings also so that they do not accidentally drop inside the vessel clean the basket O ring and vessel by hand or by flushing whichever is appropriate for the application an...

Страница 8: ...r if they are not lubricated regularly The davit nut and arm via the grease nipple fitted should be kept well greased Grease selection should be appropriate for the operating environment Inspect the c...

Страница 9: ...for product damage or personal injuries sustained when the product is modified in anyway This warranty shall not apply to products which have been used other than for their intended use misuse neglig...

Страница 10: ...6 42 EC on Machinery according to Annex VIII This product has used Harmonized Standard EN809 1998 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance The conforma...

Отзывы: